journal article·2025-12-31

Influence of N 2 flow rate on the structure, hardness, and bioactivity of TiN/Cu coatings on NiTi alloy by RF magnetron sputtering

Mohammad Javad Salek Rahimi, Abbas Kianvash, Mohammad Yousef Memar, Mohammad Rezvani

Materials Technology· Volume 40· Issue 1
Publisher page

Abstract

NiTi alloys are widely used for their unique properties; however, long-term biomedical applications require enhanced surface characteristics. In this study, TiN/Cu composite coatings were deposited on NiTi substrates using magnetron sputtering, examining N₂ gas flow rate effects (5, 10, 15 sccm) on structure, hardness, and bioactivity. FESEM/EDS analyses showed denser microstructures and higher Cu/N contents with increasing N₂ flow rate. XRD patterns indicated a TiN phase preferred orientation shift from (111) to (200). Ti₂Cu phase peaks were detected in N-5 and slightly in N-10 samples but disappeared at N-15, where Cu segregated in amorphous form. Higher N₂ flow enhanced coating hardness and suppressed toxic Ni²⁺ ion release, while Cu²⁺ remained within safe limits. However, bioactivity evaluation in simulated body fluid (SBF) demonstrated improved apatite formation at lower N₂ flow rates, attributed to increased surface roughness, hydrophilicity, and Ti-Cu intermetallic phases promoting biological integration.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Shape Memory Alloy Transformations · Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering, Institute of Mechanical Engineering, University of Tabriz

Infectious and Tropical Diseases Research Center, Tabriz University of Medical Sciences

References (34)

Show source-provided references
1. 10.3389/fbioe.2024.132570710.3389/fbioe.2024.1325707 ↗
2. 10.1007/978-981-13-2490-1_2810.1007/978-981-13-2490-1_28 ↗
3. 10.2478/aoj-2009-001110.2478/aoj-2009-0011 ↗
4. 10.1007/s10266-018-0387-910.1007/s10266-018-0387-9 ↗
5. 10.1063/5.022886610.1063/5.0228866 ↗
6. 10.1038/s41467-020-15165-410.1038/s41467-020-15165-4 ↗
7. 10.4238/201310.4238/2013 ↗
8. 10.1515/jbcpp-2017-017110.1515/jbcpp-2017-0171 ↗
9. 10.1134/S207020511401009210.1134/S2070205114010092 ↗
10. 10.3390/coatings1301006910.3390/coatings13010069 ↗
11. 10.1080/00202967.2025.245013810.1080/00202967.2025.2450138 ↗
12. Nasakina EO, Sevostyanov MA, Baikin AS, et al. Using of magnetron sputtering for biocompatible composites creating. Biocompatible Composite Materials for Biomedical Applications. London: IntechOpen; 2019. pp. 1–21.
13. 10.1016/j.msec.2015.01.00910.1016/j.msec.2015.01.009 ↗
14. 10.1016/j.msec.2017.05.05210.1016/j.msec.2017.05.052 ↗
15. 10.1016/j.toxlet.2005.10.00310.1016/j.toxlet.2005.10.003 ↗
16. 10.1016/j.matdes.2016.08.05010.1016/j.matdes.2016.08.050 ↗
17. Lichtenegger HC, Schoberl T, Bartl MH, et al. High abrasion resistance with sparse mineralization: copper biomineral in worm jaws. Natur. 2002;410:298–300.
18. 10.3390/coatings1309158710.3390/coatings13091587 ↗
19. 10.1063/1.35153310.1063/1.351533 ↗
20. 10.1016/S0040-6090(02)00602-810.1016/S0040-6090(02)00602-8 ↗
21. 10.1016/j.tsf.2021.13864510.1016/j.tsf.2021.138645 ↗
22. 10.1080/01694243.2023.220927410.1080/01694243.2023.2209274 ↗
23. 10.1116/1.145058010.1116/1.1450580 ↗
24. 10.1088/0022-3727/30/1/00210.1088/0022-3727/30/1/002 ↗
25. 10.1021/acsbiomaterials.2c0055010.1021/acsbiomaterials.2c00550 ↗
26. 10.1080/02670844.2017.128383410.1080/02670844.2017.1283834 ↗
27. 10.2174/187153032066620012215580410.2174/1871530320666200122155804 ↗
28. 10.1016/j.biomaterials.2014.12.02210.1016/j.biomaterials.2014.12.022 ↗
29. 10.3390/jfb303068810.3390/jfb3030688 ↗
30. 10.1016/j.biomaterials.2006.01.01710.1016/j.biomaterials.2006.01.017 ↗
31. 10.3390/ijms2103078310.3390/ijms21030783 ↗
32. 10.1016/j.electacta.2012.05.10610.1016/j.electacta.2012.05.106 ↗
33. 10.1002/jbm.a.3418410.1002/jbm.a.34184 ↗
34. 10.1016/j.colsurfb.2020.11088910.1016/j.colsurfb.2020.110889 ↗