Corrosion evaluation of orthodontic wires in artificial saliva solutions by using response surface methodology
Source abstract
Abstract
In the present work, stainless steel and Ni-Ti commercial orthodontic wires were immersed in artificial saliva solutions, containing or not F- ions, in different pH values, during 30 days. The weight loss and the Ni2+ content in the solutions at 15 and 30 days of exposition were evaluated using a composite design 2³ and response surface methodology. The open circuit potential (OCP) was measured over the same period of time. Polarization curves and morpHological analysis of the wires before and after the corrosion experiments were also carried out. The results showed that corrosion of the studied metal alloys depended on a combination among saliva pH, the exposition time, and the concentration of F- ions in the solution. The critical condition was observed for Ni-Ti wires at pH = 3.0, and high concentration of F- ions, causing a decrease in the OCP values and an increase in Ni dissolution and corrosion current density.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Universidade do Estado do Rio de Janeiro, Brasil
References (35)
Show source-provided references
1. Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation10.1016/j.actbio.2005.07.008 ↗
2. Relevant aspects in the clinical applications of NiTi shape memory alloys10.1007/BF00122008 ↗
3. Ferreira NA
4. Ion release from NiTi orthodontic wires in artificial saliva with various acidities10.1016/S0142-9612(03)00188-1 ↗
5. Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires10.1016/j.biomaterials.2003.11.042 ↗
6. Skin and mucosal reactions associated with dental materials10.1046/j.0909-8836.1998.eos10602ii08.x ↗
7. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
8. Biodegradation of orthodontic appliances: 1. Biodegradation of nickel and chromium invitro10.1016/0889-5406(93)70098-9 ↗
9. Corrosion of orthodontic wires according to heat treatment conditions10.2320/matertrans.43.3078 ↗
10. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G ↗
11. Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances10.2319/083007-401.1 ↗
12. Variations in surface characteristics and corrosion behaviour of metal brackets and wires in different electrolyte solutions10.1093/ejo/cjp146 ↗
13. Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesis
14. Salivary metal levels of orthodontic patients: a novel methodological and analytical approach10.1093/ejo/25.1.103 ↗
15. Comparison of ion release from new and recycled orthodontic brackets10.1067/mod.2001.113794 ↗
16. Metal ion release from fixed orthodontic appliances: an in vivo study10.1093/ejo/cjq181 ↗
17. Intraoral aging of orthodontic alloys: implications for corrosion potential, nickel release and biocompatibility
18. Senna LFR · 2011
19. 2012
20. 2012
21. Cawson RAR · 1998 · 36
22. Variation in surface topograpHy of different NiTi orthodontic archwires in various commercial fluoride-containing environments10.1016/j.dental.2005.11.042 ↗
23. Corrosion resistance of different nickel-titanium archwires in acidic fluoride-containing artificial saliva10.2319/042909-235.1 ↗
24. Pourbaix M · 1987
25. Afshar A · 2005
26. Corrosion resistance of titanium-containing dental orthodontic wires in fluoride-containing artificial saliva10.1016/j.jallcom.2009.09.015 ↗
27. Results of a 3-year oral hygiene program, including amine fluoride products, in patients treated with fixed orthodontic appliances10.1093/ejo/13.2.129 ↗
28. Comparison of 3 self-applied topical fluoride preparations for control of decalcification
29. Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium10.1016/S0142-9612(01)00079-5 ↗
30. Sensitivity of titanium brackets to the corrosive influence of fluoride-containing toothpaste and tea
31. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys10.1016/S0142-9612(01)00328-3 ↗
32. Influence of fluoride concentration and pH on corrosion behavior of titanium in artificial saliva10.1007/s10800-006-9283-z ↗
33. Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution10.1002/jbm.b.30505 ↗
34. The corrosion resistance of pure titanium in organic acids10.1016/S0142-9612(01)00040-0 ↗
35. Degradation of tensile strength of Ni-/Ti superelastic alloy due to hydrogen absorption in methanol solution containing hydrochloric acid10.1016/S0921-5093(03)00403-9 ↗