journal article·2025-09-01

A New Standard for Visual Acuity Testing of Radiographic Interpreters: ASTM E3168

David A. Fry, Uwe Zscherpel, Thomas S. Jones

Materials Evaluation· Volume 83· Issue 9
Publisher page

Abstract

The vision requirements for radiographic interpreters, per certification practices, consist of standard vision tests with high-contrast, sharp, noiseless characters (optotypes). However, radiographic interpretation involves detecting low-contrast, blurred, and often noisy or grainy indications. Studies conducted in the late 1970s and early 1980s introduced a new optotype for evaluating the vision of radiographic interpreters: linear slit images of varying contrast and blurring. After years of trying to find a suitable film for these images to be printed on, a printer/film system was finally identified in 2021 that produced stable films when placed on a hot film illuminator. Prototypes were printed, and studies were performed to capture statistics on the detectability of the various images. This work enabled the approval and publication of a new ASTM International standard for visual acuity of radiographic interpreters. This tutorial details the development of the standard and its usage.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiology practices and education · Traumatic Ocular and Foreign Body Injuries · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. 1. Committee on Vision. 1980. “Recommended Standard Procedures for the Clinical Measurement and Specification of Visual Acuity.” Report of Working Group 39, in Advances in Ophthalmology 41: 103–148. Assembly of Behavioral and Social Sciences, National Research Council, National Academy of Sciences, Washington, DC.
2. 2. Ricci, F., C. Cedrone, and L. Cerulli. 1998. “Standardized measurement of visual acuity.” Ophthalmic Epidemiology 5 (1): 41–53. https://doi.org/10.1076/opep.5.1.41.1499.10.1076/opep.5.1.41.1499 ↗
3. 3. Yonemura, G. T. 1981. “Visual Acuity Testing of Radiographic Inspectors in Nondestructive Inspection.” NBS Technical Note 1143. https://doi.org/10.6028/NBS.TN.1143.10.6028/nbs.tn.1143 ↗
4. 4. ASTM. 2020. ASTM E3168: Standard Practice for Determining Low-Contrast Visual Acuity of Radiographic Interpreters. ASTM International. West Conshohocken, PA. https://doi.org/10.1520/E3168-20.10.1520/e3168-20 ↗
5. 5. Yonemura, G. T. 1977. “Considerations and Standards for Visual Inspection Techniques.” In STP624: Nondestructive Testing Standards – A Review, H. Berger (ed.). ASTM International. West Conshohocken, PA. https://doi.org/10.1520/STP27035S.10.1520/stp27035s ↗
6. 6. National Electrical Manufacturers Association. 2024. DICOM PS3.1 2024e (Digital Imaging and Communications in Medicine). dicomstandard.org.
7. 7. Jones, T. S. 4 February 1998. “Review of Visual Acuity Images,” in Industrial Quality Inc. memo to ASTM E07.93 Illustration Monitoring Subcommittee members.
8. 8. Howmet Castings. 2003. “Low Contrast Visual Acuity Images – Round Robin Test Results January 2003.”