Rail Flaw Imaging Prototype Based on Improved Ultrasonic Synthetic Aperture Focus Method
Source abstract
Abstract
This paper presents an experimental prototype developed for rail flaw imaging. This capability can help obtain quantitative information on detected flaws during manual flaw verification. Ultrasonic synthetic aperture focus (SAF) imaging has advantages over phased-array imaging for both speed and accuracy. The prototype developed is hosted in a portable and battery-powered carry-on size case. The probe is a linear ultrasonic array mounted on a wedge and with a position encoder to build 3D point clouds from 2D beamformed images. The prototype includes several advances over the basic SAF technique, including sparse subarray firing that allows fast imaging speeds (e.g., 25 Hz) without sacrificing image accuracy. Validation results are presented from scans performed on rail sections from the FRA rail defect library, which contains natural transverse defects and artificial end-drilled hole defects. The tests showed good accuracy in defect size and shape, as compared to the available ground truth information, for defects located away from the railhead corners. Additional developments are required to properly cover the head corners, and especially in the case of heavily worn rails.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Geophysical Methods and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Drinkwater, B. W., and P. D. Wilcox. 2006. “Ultrasonic arrays for non-destructive evaluation: A review.” NDT & E International 39 (7): 525–41. https://doi.org/10.1016/j.ndteint.2006.03.006.10.1016/j.ndteint.2006.03.006 ↗
2. Flaherty, J. J., K. R. Erikson, and V. M. Lund. 1967. Synthetic aperture ultrasonic imaging systems. U.S. Patent 3,548,642, filed 2 March 1967, and issued 22 December 1970.
3. Frazier, C. H., and W. D. O’Brien. 1998. “Synthetic aperture techniques with a virtual source element.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 45 (1): 196–207. https://doi.org/10.1109/58.646925.10.1109/58.646925 ↗
4. Hu, H., X. Zhu, C. Wang, L. Zhang, X. Li, S. Lee, Z. Huang, et al. 2018. “Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces.” Science Advances 4 (3): eaar3979. https://doi.org/10.1126/sciadv.aar3979.10.1126/sciadv.aar3979 ↗
5. Huang, C., and F. Lanza di Scalea. 2022. “High Resolution Real Time Synthetic Aperture Imaging in Solids Using Virtual Elements,” Proceedings of the ASME 2022 International Mechanical Engineering Congress and Exposition. Volume 9: Mechanics of Solids, Structures, and Fluids; Micro- and Nano-Systems Engineering and Packaging; Safety Engineering, Risk, and Reliability Analysis; Research Posters. https://doi.org/10.1115/IMECE2022-94445.10.1115/imece2022-94445 ↗
6. Jensen, J. A., S. I. Nikolov, K. L. Gammelmark, and M. H. Pedersen. 2006. “Synthetic aperture ultrasound imaging.” Ultrasonics 44 (Suppl. 1): e5–15. https://doi.org/10.1016/j.ultras.2006.07.017.10.1016/j.ultras.2006.07.017 ↗
7. Karaman, M., P. -C. Li, and M. O’Donnell. 1995. “Synthetic aperture imaging for small scale systems.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 42 (3): 429–42. https://doi.org/10.1109/58.384453.10.1109/58.384453 ↗
8. Lockwood, G. R., J. R. Talman, and S. S. Brunke. 1998. “Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 45 (4): 980–88. https://doi.org/10.1109/58.710573.10.1109/58.710573 ↗
9. Lanza di Scalea, F., 2007, “Ultrasonic testing applications in the railroad industry,” Chapter 15: Special Applications of Ultrasonic Testing, in Non-destructive Testing Handbook, 3rd edition, P.O. Moore, ed., American Society for Nondestructive Testing, pp. 535-552.10.1016/b978-0-444-87450-4.50051-5 ↗
10. Lanza di Scalea, F., S. Sternini, and T. V. Nguyen. 2017. “Ultrasonic imaging in solids using wave mode beamforming.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 64 (3): 602–16. https://doi.org/10.1109/TUFFC.2016.2637299.10.1109/tuffc.2016.2637299 ↗
11. Martin-Arguedas, C. J., D. Romero-Laorden, O. Martinez-Graullera, M. Perez-Lopez, and L. Gomez-Ullate. 2012. “An ultrasonic imaging system based on a new SAFT approach and a GPU beamformer.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 59 (7): 1402–12. https://doi.org/10.1109/TUFFC.2012.2341.10.1109/tuffc.2012.2341 ↗
12. Sternini, S., A. Y. Liang, and F. Lanza di Scalea. 2019a. “Ultrasonic synthetic aperture imaging with interposed transducer–medium coupling path.” Structural Health Monitoring 18 (5-6): 1543–56. https://doi.org/10.1177/1475921718805514.10.1177/1475921718805514 ↗
13. Sternini, S., A. Y. Liang, and F. Lanza di Scalea. 2019b. “Rail Defect Imaging by Improved Ultrasonic Synthetic Aperture Focus Techniques.” Materials Evaluation 77 (7): 931–40.
14. Witte, M., and A. Poudel. 2016. “High-speed rail flaw detection using phased array ultrasonics.” Technology Digest TD16-030.