journal article·2022-07Open access

On the design of a piezoelectric self-sensing smart composite laminate

Maria Elena Gino, Giacomo Selleri, Davide Cocchi, Tommaso Maria Brugo, Nicola Testoni, Luca De Marchi, Andrea Zucchelli, Davide Fabiani, Maria Letizia Focarete

Materials & Design· Volume 219

Abstract

The structural health monitoring of composite laminates is a rapidly emerging need in structural applications. Different real-time sensors integrated into laminates have been proposed, such as fiber Bragg gratings and piezoceramics. However, their presence negatively affects the mechanical properties of the hosting laminate. This work proposes a non-invasive method for piezoelectric functionalization of composite laminates by interleaving lead zirconate titanate micrometric powder between glass-fiber-reinforced polymer plies. The effects of different powder volume fractions on the electromechanical properties were evaluated in terms of the electrical response and laminate inherent strength. The lead zirconate titanate powder laminates demonstrated an electrical sensitivity value that was up to 439% higher compared with that of the embedded commercial disk laminate (12.4 V/kN versus 2.3 V/kN). Impact tests revealed that the resistance of the interleaved lead zirconate titanate powder laminates is comparable to that of the pristine laminates, whereas a fragile commercial disk leads to delamination. Furthermore, an analytical model was proposed to predict the piezoelectric voltage coefficient g33 as a function of the electrical properties, volumetric powder fractions, and polarization process. The model matched the experimental g33 coefficients (R2=0.97), demonstrating its capability to predict the electromechanical behavior of piezoelectric composites and define their design guidelines.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Smart Materials for Construction · Structural Health Monitoring Techniques · Ultrasonics and Acoustic Wave Propagation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Effect of fibers configuration and thickness on tensile behavior of GFRP laminates exposed to harsh environment10.3390/polym11091401 ↗
2. Impact damage location in composite structures using optimized sensor triangulation procedure10.1088/0964-1726/12/5/017 ↗
3. A review on smart self-sensing composite materials for civil engineering applications10.3934/matersci.2016.2.357 ↗
4. P. Hofmann, A. Walch, A. Dinkelmann, S. K. Selvarayan, and G. T. Gresser, “Woven piezoelectric sensors as part of the textile reinforcement of fiber reinforced plastics,” Compos. Part A Appl. Sci. Manuf., vol. 116, no. October 2018, pp. 79–86, 2019, doi: 10.1016/j.compositesa.2018.10.019.10.1016/j.compositesa.2018.10.019 ↗
5. Structural Health Monitoring for Composite Materials
6. A review of manufacturing techniques of smart composite structures with embedded bulk piezoelectric transducers10.1088/1361-665X/ab0fab ↗
7. Recent Progress in Flexible Pressure Sensors Based Electronic Skin10.1002/adem.202001187 ↗
8. Microstructured optical fiber Bragg grating as an internal three-dimensional strain sensor for composite laminates10.1088/0964-1726/24/5/055003 ↗
9. Failure mechanics of a composite laminate embedded with a fiber optic sensor10.1177/0021998305048156 ↗
10. Rapid-Response, Low Detection Limit, and High-Sensitivity Capacitive Flexible Tactile Sensor Based on Three-Dimensional Porous Dielectric Layer for Wearable Electronic Skin10.1021/acsami.9b16511 ↗
11. A. Huijer, C. Kassapoglou, and L. Pahlavan, “Acoustic emission monitoring of carbon fibre reinforced composites with embedded sensors for in‐situ damage identification,” Sensors, vol. 21, no. 20, 2021, doi: 10.3390/s21206926.10.3390/s21206926 ↗
12. Using passive and active acoustic methods for impact damage assessment of composite structures
13. J. Jiang, J. Jiang, X. Deng, and Z. Deng, “Detecting debonding between steel beam and reinforcing CFRP plate using active sensing with removable PZT-based transducers,” Sensors (Switzerland), vol. 20, no. 1, 2020, doi: 10.3390/s20010041.10.3390/s20010041 ↗
14. Structural health monitoring of polymer-matrix composite using embedded piezoelectric ceramic transducers during several four-points bending tests10.1088/1361-665X/abbc59 ↗
15. Damage Localization in Composite Laminates by Building in PZT Wafer Transducers: A Comparative Study with Surface-Bonded PZT Strategy10.1002/adem.201801040 ↗
16. Effect of embedded sensors on interlaminar damage in composite structures10.1177/1045389X11414225 ↗
17. Integration of piezoelectric transducers (PZT and PVDF) within polymer-matrix composites for structural health monitoring applications: new success and challenges10.1080/19475411.2020.1830196 ↗
18. The effects of embedded piezoelectric fiber composite sensors on the structural integrity of glass-fiber–epoxy composite laminate10.1088/0964-1726/21/1/015016 ↗
19. Characteristics and fabrication of piezoelectric GFRP using smart resin prepreg for detecting impact signals10.1016/j.compscitech.2018.08.002 ↗
20. Self-sensing hybrid composite laminate by piezoelectric nanofibers interleaving10.1016/j.compositesb.2021.108673 ↗
21. Ferroeletric polymers10.1080/00018739200101463 ↗
22. Polarization Dynamics of VDF-TrFE Copolymers10.1109/14.68230 ↗
23. Piezoelectric Accelerometers and Vibration Preamplifiers: Theory and Application Handbook
24. Flexible composite transducers10.1016/0025-5408(78)90185-X ↗
25. Connectivity and piezoelectric-pyroelectric composites10.1016/0025-5408(78)90161-7 ↗
26. Low velocity impact damage assessment of GLARE fiber-metal laminates interleaved by Nylon 6,6 nanofiber mats10.1016/j.compstruct.2017.01.079 ↗
27. Designing a HVDC Insulation System to Endure Electrical and Thermal Stresses under Operation. Part I: Partial Discharge Magnitude and Repetition Rate during Transients and in DC Steady State10.1109/ACCESS.2021.3062440 ↗
28. Study on the polarization process for piezoelectric nanofibrous layers
29. On the calculation of the dielectric time constant of DC insulators containing cavities
30. Industrial High DC Voltage: 1. FIelds 2
31. Abrate · 2005