journal article·2025-03Open access

Design, fabrication, and characterization of novel dental implants with porosity gradient obtained by Selective Laser Melting

Amanda Robau-Porrua, Jesús E. González, Roberto Arancibia-Castillo, Alberto Picardo, Eugenia Araneda-Hernández, Yadir Torres

Materials & Design· Volume 251

Abstract

• Advanced SLM is suitable for manufacturing complex dental implant designs. • Design of new dental implants for immediate loads with porosity gradients. • Porous dental implants with radial porosity show a better biomechanical balance. • FEM a fast and effective tool to evaluate the stress shielding phenomenon. Porous dental implants represent a significant advancement in dentistry, offering improved osseointegration, reduced bone resorption and minimized stiffness to better interact with surrounding bone. This study focuses on the development of Ti6Al4V implants with immediate loading and controlled porosity (40 vol% and 600 µm pore size) to improve vascularization and bone ingrowth, which are crucial for successful integration and long-term performance. Dense implants, fully porous implants, and a hybrid design combining a porous surface with a dense core were fabricated using Selective Laser Melting, enhancing fatigue resistance under cyclic loads. Porosity was quantified, revealing 19 % through image analysis and 13 % via the Archimedes method. Finite Element Analysis demonstrated that porous implants improve stress distribution, facilitate load transfer to peri -implant trabecular bone, and achieve uniform stress and strain distributions between thread fillets, with values ranging from 1.1 MPa to 1.6 MPa for stress and 0.0002 to 0.0030 for strain, promoting bone growth. Comparisons with β-Ti alloy implants featuring a porous structure and dense core revealed reduced stress concentrations and a lower risk of fatigue failure. These findings highlight the potential of hybrid and β-Ti designs for personalized dental implants, balancing mechanical performance with biological compatibility to meet patient-specific needs.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (85)

Show source-provided references
1. Behavior of mandibular canines as abutment teeth and indirect retainers in Kennedy class II Removable Partial Denture Prosthesis10.1016/j.heliyon.2018.e00575 ↗
2. Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis10.1016/j.jds.2022.05.026 ↗
3. Uzcátegui · Biomecánica De Implantes Dentales · 2018
4. Mechanical properties of porous structures for dental implants: Experimental study and computational homogenization10.3390/ma14164592 ↗
5. Review on finite element analysis of dental implants10.54527/jdir.2022.41.3.50 ↗
6. Biomechanical performance of Ti-PEEK dental implants in bone: An in-silico analysis10.1016/j.jmbbm.2022.105422 ↗
7. Stress distribution in dental prosthesis under an occlusal combined dynamic loading10.1016/j.matdes.2011.12.006 ↗
8. Biomechanical analysis of printable functionally graded material (FGM) dental implants for different bone densities10.1016/j.compbiomed.2022.106111 ↗
9. Comparative evaluation of osseointegrated dental implants based on platform-switching concept: Influence of diameter, length, thread shape, and in-bone positioning depth on stress-based performance10.1155/2013/250929 ↗
10. Macrodesign of Dental implant-A review, Journal of Applied Dental and Medical
11. F. Cavas, M. Guillermo, P.-F. Paz, M. Camo, I.L. Lengua, B. Defez, G. Editors, Advances in Design Engineering II, 2021. https://link.springer.com/bookseries/11236.
12. Novel design of additive manufactured hollow porous implants10.1016/j.dental.2020.08.011 ↗
13. Mechanical aspects of dental implants and osseointegration: A narrative review10.1016/j.jmbbm.2019.103574 ↗
14. Implant Surface Material, Design, and Osseointegration10.1016/j.cden.2014.12.003 ↗
15. Biomechanical analysis of the osseointegration of porous tantalum implants10.1016/j.prosdent.2019.09.014 ↗
16. Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting10.1088/1758-5090/8/4/045014 ↗
17. Revised, Computed Tomography–Based Lekholm and Zarb Jawbone Quality Classification10.11607/ijp.5714 ↗
18. Survival of the Brånemark Implant in Partially Edentulous Jaws: A 10-Year Prospective Multicenter Study
19. Assessment of stress shielding around a dental implant for variation of implant stiffness and parafunctional loading using finite element analysis
20. Ti6Al4V orthopedic implant with biomimetic heterogeneous structure via 3D printing for improving osteogenesis10.1016/j.matdes.2022.110964 ↗
21. Heterogeneous porosity design triggered stress reorganization to avoid intervertebral cage subsidence and promote spinal fusion10.1016/j.compstruct.2023.117516 ↗
22. The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study10.1016/j.jmbbm.2023.105847 ↗
23. Novel design and finite element analysis of diamond-like porous implants with low stiffness
24. The Influence of Mechanical Loads on the Biomechanics of Dental Implant
25. Finite Element Analysis of the Stress Distribution Associated With Different Implant Designs for Different Bone Densities10.1111/jopr.13539 ↗
26. In vitro bone strain analysis of implant following occlusal overload10.1111/clr.12059 ↗
27. Peri-Implant bone response around porous-surface dental implants: A preclinical meta-analysis, Saudi
28. Porous titanium for dental implant applications10.3390/met5041902 ↗
29. Fatigue behavior of porous biomaterials manufactured using selective laser melting10.1016/j.msec.2013.08.006 ↗
30. Mechanical properties of porous titanium with different distributions of pore size10.1016/S1003-6326(13)62735-1 ↗
31. Mechanical Properties of Porous Structures Produced by Selective Laser Melting of a Ti6Al4V
32. Biomechanical behavior of a new design of dental implant: Influence of the porosity and location in the maxilla10.1016/j.jmrt.2024.02.091 ↗
33. Fatigue behavior and osseointegration of porous Ti-6Al-4V scaffolds with dense core for dental application10.1016/j.matdes.2020.108994 ↗
34. Selective laser melting processed Ti6Al4V lattices with graded porosities for dental applications10.1016/j.jmbbm.2018.08.047 ↗
35. Finite element analysis of stress at implant-bone interface of dental implants with different structures10.1016/S1003-6326(11)60903-5 ↗
36. Finite element analyses of porous dental implant designs based on 3D printing concept to evaluate biomechanical behaviors of healthy and osteoporotic bones10.1080/15376494.2022.2053908 ↗
37. Three-dimensional finite element investigation into effects of implant thread design and loading rate on stress distribution in dental implants and anisotropic bone10.3390/ma14226974 ↗
38. L. Himmlová, jana Dostálová, A. KácovskyKácovsky, S. Konvic, Influence of implant length and diameter on stress distribution: A finite element analysis, J Prosthet Dent 91 (2004).10.1016/j.prosdent.2003.08.008 ↗
39. Finite element analysis of narrow dental implants10.1016/j.dental.2020.04.013 ↗
40. Fatigue behaviour of dental implant using finite element method10.1016/j.matpr.2021.10.341 ↗
41. J. Zhang, X. Zhang, X. Peng, P. Zhang, X. Chen, Effect of internal and external porous structure design on stress distribution of implant bridge: A Finite element analysis, in: Proceedings - 2020 3rd International Conference on Electron Device and Mechanical Engineering, ICEDME 2020, Institute of Electrical and Electronics Engineers Inc., 2020: pp. 305–309. https://doi.org/10.1109/ICEDME50972.2020.00077.10.1109/ICEDME50972.2020.00077 ↗
42. 3D Printing of Ti-6Al-4V-Based Porous-Channel Dental Implants: Computational
43. Review on manufacture by selective laser melting and properties of titanium based materials for biomedical applications10.1179/1753555715Y.0000000076 ↗
44. Microstructure and mechanical properties investigation of CP titanium processed by selective laser melting (SLM)10.1016/j.jmatprotec.2016.10.022 ↗
45. Selective Laser Melting of Titanium Alloys and Titanium Matrix Composites for Biomedical Applications: A Review10.1002/adem.201500419 ↗
46. Microstructure and mechanical behavior of porous Ti-6Al-4V parts obtained by selective laser melting10.1016/j.jmbbm.2013.05.011 ↗
47. Optimization of processing parameters and establishment of a relationship between microstructure and mechanical properties of SLM titanium alloy10.1016/j.optlastec.2018.11.014 ↗
48. Development of highly porous titanium scaffolds by selective laser melting10.1016/j.matlet.2009.12.035 ↗
49. Icariin-loaded 3D-printed porous Ti6Al4V reconstruction rods for the treatment of necrotic femoral heads10.1016/j.actbio.2023.07.057 ↗
50. Bone conduction capacity of highly porous 3D-printed titanium scaffolds based on different pore designs10.3390/ma14143892 ↗
51. Optimization Design and SLM Manufacturing of Porous Titanium Alloy Femoral Stem10.3390/ma17194896 ↗
52. Fracture mechanics-based analysis of the fatigue limit of Ti6Al4V alloy specimens manufactured by SLM in as-built surface conditions by means of areal measurements10.1016/j.engfracmech.2023.109720 ↗
53. Optimization of SLM process parameters for Ti6Al4V medical implants10.1108/RPJ-05-2018-0112 ↗
54. Scanning strategy in selective laser melting (SLM): a review10.1007/s00170-021-06810-3 ↗
55. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products 1, 2006. https://doi.org/10.1520/C0373-88R06.10.1520/C0373-88R06 ↗
56. Surface roughness of Ti-6Al-4V parts obtained by SLM and EBM: Effect on the High Cycle Fatigue life, in10.1016/j.proeng.2018.02.010 ↗
57. Biomechanical Consequences of the Elastic Properties of Dental Implant Alloys on the Supporting Bone: Finite Element Analysis10.1155/2016/1850401 ↗
58. Findings and perspectives of β-Ti alloys with biomedical applications: Exploring beyond biomechanical and biofunctional behaviour10.1016/j.jmrt.2024.09.248 ↗
59. Biomechanical analysis of different implant-abutments interfaces in different bone types: An in silico analysis10.1016/j.msec.2018.05.012 ↗
60. A mathematical model for simulating the bone remodeling process under mechanical stimulus10.1016/j.dental.2006.10.004 ↗
61. Bite Force and Influential Factors on Bite Force Measurements: A Literature Review, Eur
62. Maximum voluntary bite force, occlusal contact points and associated stresses on posterior teeth10.1080/03036758.2019.1691612 ↗
63. Correlation between Implant Surface Roughness and Implant Stability: A Systematic Review10.3390/dj12090276 ↗
64. M.M. Shalabi, A. Gortemaker, M.A. Van’t Hof, J.A. Jansen, N.H.J. Creugers, Implant surface roughness and bone healing a systematic review, J Dent Res 85 (2006). https://doi.org/10.1177/154405910608500603.10.1177/154405910608500603 ↗
65. Mechanisms of defect formation in Ti-6Al-4V product during re-melting of layers in selective laser melting10.1016/j.jmapro.2023.09.044 ↗
66. Porous structure design and mechanical behavior analysis based on TPMS for customized root analogue implant10.1016/j.jmbbm.2020.104222 ↗
67. Fabrication and characterization of superficially modified porous dental implants10.1016/j.surfcoat.2020.126796 ↗
68. Selective laser melting of ti-6al-4v: The impact of post-processing on the tensile, fatigue and biological properties for medical implant applications10.3390/ma13122813 ↗
69. Study on Surface Roughness Improvement of Selective Laser Melted Ti6Al4V Alloy
70. Designing bioactive porous titanium interfaces to balance mechanical properties and in vitro cells behavior towards increased osseointegration10.1016/j.surfcoat.2019.03.001 ↗
71. The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
72. Finite element and experimental analysis to select patient’s bone condition specific porous dental implant, fabricated using additive manufacturing10.1016/j.compbiomed.2020.103839 ↗
73. Titanium Alloys for Dental Implants: A Review10.3390/prosthesis2020011 ↗
74. Study of the compression behaviour of Ti6Al4V trabecular structures produced by additive laser manufacturing10.3390/ma12091471 ↗
75. The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis10.1016/j.dental.2021.08.022 ↗
76. H.M. Frost, Bone’s Mechanostat: A 2003 Update, Anatomical Record - Part A Discoveries in Molecular, Cellular, and Evolutionary Biology 275 (2003) 1081–1101. https://doi.org/10.1002/ar.a.10119.10.1002/ar.a.10119 ↗
77. S.-E. Widmalm, S. Gottmar Ericsson, Maximal bite force with centric and eccentric load, 1982.10.1111/j.1365-2842.1982.tb01034.x ↗
78. Finite element analysis of the human mastication cycle10.1016/j.jmbbm.2014.09.022 ↗
79. P. Dhatrak, U. Shirsat, V. Deshmukh, Finite Element Analysis and Experimental Investigations on Stress Distribution of Dental Implants around Implant-Bone Interface, 2018. www.sciencedirect.comwww.materialstoday.com/proceedings.10.1016/j.matpr.2017.12.157 ↗
80. M.O. Hussein, Biomechanical Analysis of Different Implant-Overdenture Loading Protocols under Dynamic loads, 2013. http://www.jofamericanscience.orghttp://www.jofamericanscience.org.12.
81. Bilinear elastic property of the periodontal ligament for simulation using a finite element mandible model10.4012/dmj.2010-170 ↗
82. Mechanical behaviors and failure modes of additive manufactured Ti6Al4V lattice structures under compressive load10.1016/j.tws.2022.109778 ↗
83. Heat treatment of Ti6Al4V produced by Selective Laser Melting: Microstructure and mechanical properties10.1016/j.jallcom.2012.07.022 ↗
84. Review of laser powder bed fusion (LPBF) fabricated Ti-6Al-4V: process, post-process treatment, microstructure, and property
85. Fatigue life of dental implant a review