Numerical studies on shear resistance of headed stud connectors in different concretes under Arctic low temperature
Source abstract
Abstract
Abstract Steel-Concrete-Steel (SCS) sandwich composite plate or shell structure has emerged as a viable solution for the Arctic offshore structure. Headed stud connectors are the essential structural components to enforce the composite action in the steel-concrete interface in these structures. This paper presents a parametric investigation on the shear resistance and failure mechanism in the shear connectors under low temperatures representing the Arctic conditions. The finite element (FE) approach used in the parametric study considers both material and geometric nonlinearities. Validation of the finite element procedure utilizes 54 previously reported experimental tests, with the objective to confirm the accuracy of the FE approach in predicting both the failure mechanism and the ultimate shear resistance of the stud connectors. The numerical study performs subsequently a comprehensive parametric investigation on 96 stud connectors, with the mechanical properties of the steel and concrete material measured at low ambient temperatures. To facilitate the engineering design of these connectors at low temperature conditions, this paper integrates the enhancement factors of the steel and concrete materials in a shear resistance estimation recommended in Eurocode 4.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. Assessment of undiscovered oil and gas in the Arctic10.1126/science.1169467 ↗
2. Liu · 2011
3. Punching shear resistance of slabs and shells used for Arctic concrete platforms
4. Design of concrete gravity structures to withstand concentrated ridge and floe impact loads
5. Resistance of concrete walls to high concentrated ice loads
6. Punching shear of reinforced concrete shell structures
7. Bond enhancement for sandwich shell ice wall
8. Steel-concrete-steel sandwich system in Arctic offshore structure: materials, experiments, and design10.1016/j.matdes.2015.11.084 ↗
9. Shear-tension interaction strength of J-hook connectors in steel-concrete-steel sandwich structure
10. Push-out tests on J-hook connectors in steel–concrete–steel sandwich structure10.1617/s11527-013-0145-y ↗
11. Tensile resistance of J-hook connectors in steel-concrete-steel sandwich composite structure10.1016/j.jcsr.2014.04.023 ↗
12. Punching shear resistance of steel-concrete-steel sandwich composite shell structure10.1016/j.engstruct.2016.03.029 ↗
13. Development in sandwich construction10.1016/j.jcsr.2006.06.025 ↗
14. Double skin composite construction for submerged tube tunnels
15. Performance of shear connectors at elevated temperatures—a review10.12989/scs.2016.20.1.185 ↗
16. Behaviour of C-shaped angle shear connectors under monotonic and fully reversed cyclic loading: an experimental study10.1016/j.matdes.2012.04.039 ↗
17. Experimental assessment of channel shear connectors under monotonic and fully reversed cyclic loading in high strength concrete10.1016/j.matdes.2011.08.008 ↗
18. Numerical analysis of channel connectors under fire and a comparison of performance with different types of shear connectors subjected to fire10.12989/scs.2016.20.3.651 ↗
19. Evaluation of the transverse shear stiffness of a steel bi-directional corrugated-strip-core sandwich beam10.1016/j.jcsr.2010.07.010 ↗
20. Investigation of stud shear connectors for composite concrete and steel T-beams
21. Shear strength of stud connectors in lightweight and normal-weight concrete10.62913/engj.v8i2.160 ↗
22. Static behavior and theoretical model of stud shear connectors10.1061/(ASCE)1084-0702(2008)13:6(623) ↗
23. Static behavior of large stud shear connectors10.1016/j.engstruct.2004.07.011 ↗
24. Capacities of headed stud shear connectors in composite steel beams with precast hollow core slabs10.1016/j.jcsr.2006.11.012 ↗
25. Experimental and numerical investigation on the shear behaviour of friction-welded bar–plate connections embedded in concrete10.1016/j.jcsr.2004.10.005 ↗
26. The influence of profiled sheeting thickness and shear connector's position on strength and ductility of headed shear connector10.1016/j.engstruct.2011.01.035 ↗
27. Behaviour of headed stud shear connectors for composite steel–concrete beams at elevated temperatures10.1016/j.jcsr.2008.03.008 ↗
28. United States Central Intelligence Agency · 1978
29. Finite element modelling of push-out tests for large stud shear connectors10.1016/j.jcsr.2009.06.010 ↗
30. Bolted shear connectors vs. headed studs behaviour in push-out tests10.1016/j.jcsr.2013.05.003 ↗
31. Finite element modelling of headed stud shear connectors in steel-concrete composite beam10.1016/B978-008043948-8/50041-2 ↗
32. Numerical investigation of internal force transfer mechanism in push-out tests10.1016/j.engstruct.2013.02.021 ↗
33. Design of composite steel and concrete structures—part 1.1: general rules and rules for buildings
34. Mechanical properties of mild steel and high strength steel S690 under low temperature relevant to Arctic10.1016/j.matdes.2014.04.057 ↗
35. ABAQUS · 2012
36. Finite element analysis on ultimate strength behaviour of steel-concrete-steel sandwich composite beam structures10.1617/s11527-014-0261-3 ↗
37. Ultimate strength behaviour of steel-concrete-steel sandwich composite structures, part 2: finite element analysis10.12989/scs.2015.18.4.1001 ↗
38. A plastic-damage model for concrete10.1016/0020-7683(89)90050-4 ↗
39. Plastic-damage model for cyclic loading of concrete structures10.1061/(ASCE)0733-9399(1998)124:8(892) ↗
40. Code for design of concrete structures, GB50010-2002. Ministry of Housing and Urban–Rural Development of China; 2002 [in Chinese].
41. Stress-strain curves of structural and reinforcing steels after exposure to elevated temperatures
42. Behavior of the reinforced concrete at cryogenic temperatures10.1016/j.cryogenics.2007.07.001 ↗
43. American Concrete Institute 318 (ACI). Building Code Requirements for Structural Concrete (ACI 318–11) and Commentary. Farmington Hills (MI): American Concrete Institute; 2011.