journal article·2020-03

Indirect Impedance for Corrosion Detection of External Post-tensioned Tendons: 2. Multiple Steel Strands

Christopher L. Alexander, Mark E. Orazem

Corrosion Science· Volume 164
Publisher page

Abstract

Abstract The use of indirect impedance measurements to detect corrosion is extended to systems in which many steel strands are encased within a plastic duct. Indirect impedance measurements were applied to an extracted external tendon section from a segmentally-constructed bridge. The results, supported by numerical finite-element simulations, showed that indirect impedance measurements are sensitive to localized corrosion in field applications only if the measurements are made very near to the corroding strands.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Health Monitoring Techniques · Non-Destructive Testing Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Corrosion of post-tensioned tendons in Florida bridges
2. Initial development of methods for assessing condition of post-tensioned tendons of segmental bridges
3. Mid-bay bridge post-tensioning evaluation
4. Corrosion evaluation of post-tensioned tendons on the mid bay bridge in Destin
5. Corrosion evaluation of post-tensioned tendons on the mid-bay bridge in Destin, Florida
6. Rafols · 2012
7. Corrosion of post-tensioned tendons with deficient grout. part 2: Segregated grout with elevated sulfate content10.5006/2568 ↗
8. Corrosion failure of post-tensioning tendons in alkaline and chloride-free segregated grout: a case study10.1080/15732479.2014.887736 ↗
9. Corrosion of prestress and post-tension reinforced-concrete bridges10.1016/B978-1-78242-381-2.00003-1 ↗
10. Durable post-tensioned concrete structures
11. Failure of prestressing steel induced by crevice corrosion in prestressed concrete structures
12. Collapse of Yns-Y-gwas bridge10.1680/iicep.1988.179 ↗
13. A moratorium lifted
14. Failure of a 40 years old post tensioned bridge near seaside
15. Motor speedway bridge collapse caused by corrosion
16. Identification and demonstration of a technology adaptable to locating water in post-tensioned bridge tendons
17. Magnetic-based NDE of prestressed and post-tensioned concrete members-the MFL system
18. Literature review of chloride threshold values for grouted post-tensioned tendons
19. Ultrasonic tomography of grouted duct post-tensioned reinforced concrete bridge beams10.1016/S0963-8695(00)00035-9 ↗
20. Electrochemical polarization: I. a theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
21. Feasibility of determining corrosion rates by means of stray current-induced polarisation10.1007/s10800-008-9591-6 ↗
22. A critical examination of corrosion rate measurement techniques applied to reinforcing steel in concrete10.1002/maco.201810263 ↗
23. P.J.M. Monteiro, H. F. Morrison, Non-destructive method of determining the position and condition of reinforcing steel in concrete, US Patent 5,855,721 (1999).
24. The concept of floating electrode for contact-less electrochemical measurements: Application to reinforcing steel-bar corrosion in concrete10.1016/j.corsci.2009.05.006 ↗
25. Non-destructive measurement of corrosion state of reinforcing steel in concrete
26. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete-part 1: experimental results
27. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete-part 2: forward modeling
28. Alexander · 2019
29. Analysis of local corrosion of large metallic structures or reinforced concrete structures by electrochemical impedance spectroscopy (eis)10.1016/0013-4686(90)80012-D ↗
30. Electrochemical impedance in a thin surface electrolyte layer: Influence of the potential probe location10.1016/0013-4686(87)85011-9 ↗
31. Corrosion of post-tensioned tendons with deficient grout
32. Impedance-based detection of corrosion in post-tensioned cables: Phase 2 from concept to application
33. Lateral and radial corrosion propagation behavior materials in simulated concrete environments10.1002/maco.201206737 ↗