Abstract

Abstract The effects of acid on the corrosion and fracture behavior of Ni–Ti superelastic alloy have been examined by sustained tensile-loading test in physiological saline solution containing hydrogen peroxide. For immersion test without applied stress at the same solution pH, although corrosion is enhanced markedly irrespective of the type of acid added, corrosion morphology depends on the type of acid added. The amount of dissolved nickel ions increases in the order of the solutions with lactic acid > phosphoric acid > acetic acid. The amount of dissolved nickel ions increases with decreasing solution pH. In contrast, under applied stress, the time to fracture in the solution with phosphoric acid becomes longer than that in the solution without acid, although the time to fracture does not increase in the solution with acetic acid or lactic acid. The time to fracture is only slightly affected by solution pH for the same type of acid added. Fractographic features change in the solution with phosphoric acid. The present study suggests that the fracture behavior of Ni–Ti superelastic alloy in physiological saline solution containing hydrogen peroxide depends on acid type rather than on solution pH; the fracture behavior is not necessarily consistent with the corrosion behavior in the case without applied stress.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shape Memory Alloy Transformations · Ferroelectric and Piezoelectric Materials · Corrosion Behavior and Inhibition

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Some applications of shape-memory alloys
2. Development of shape memory alloys10.2355/isijinternational.29.353 ↗
3. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys10.3233/BME-1996-6405 ↗
4. An overview of nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
5. Physicochemical and biological aspects of Nitinol as a biomaterial10.1179/095066001771048745 ↗
6. Medical shape memory alloy applications – the market and its products10.1016/j.msea.2003.10.326 ↗
7. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?10.1177/152660280100800303 ↗
8. Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease10.1161/01.CIR.0000029746.10018.36 ↗
9. Mechanical failure of prosthetic human implants: a 10-year experience with aortic stent graft devices10.1067/mva.2003.58 ↗
10. Fracture of popliteal artery stents10.1253/circj.67.643 ↗
11. Prevalence and clinical impact of stent fractures after femoropopliteal stenting10.1016/j.jacc.2004.11.026 ↗
12. A case of popliteal stent fracture with pseudoaneurysm formation
13. Effect of exercise on frequency of stent fracture in the superficial femoral artery10.1016/j.amjcard.2006.01.091 ↗
14. Fracture of a carotid stent: an unexpected complication10.1016/j.jvs.2006.08.086 ↗
15. Fracture of Ni–Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide10.1002/jbm.a.31173 ↗
16. Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium10.1016/0142-9612(89)90043-4 ↗
17. Titanium–hydrogen peroxide interaction: model studies of the influence of the inflammatory response on titanium implants10.1016/0142-9612(89)90019-7 ↗
18. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide10.1002/jbm.820280115 ↗
19. Biological aspects of TiNi alloy surfaces
20. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
21. Hydrogen peroxide toward enhanced oxide growth on titanium in PBS solution: blue coloration and clinical relevance10.1002/(SICI)1097-4636(199603)30:3<393::AID-JBM14>3.0.CO;2-L ↗
22. Effects of Ca and H2O2 added to RPMI on the fretting corrosion of Ti6Al4V10.1002/(SICI)1097-4636(199612)32:4<519::AID-JBM4>3.0.CO;2-U ↗
23. Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro10.1002/(SICI)1097-4636(200002)49:2<238::AID-JBM12>3.0.CO;2-J ↗
24. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
25. Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium10.1002/jbm.a.10116 ↗
26. In vitro biocorrosion of Ti–6Al–4V implant alloy by a mouse macrophage cell line10.1002/jbm.a.20092 ↗
27. Changes in surface composition of the Ti–6Al–4V implant alloy by cultured macrophage cells10.1016/j.apsusc.2003.09.027 ↗
28. Delayed fracture of Ni–Ti superelastic alloys in acidic and neutral fluoride solutions10.1002/jbm.a.20122 ↗
29. Surface characterizations and corrosion resistance of nickel–titanium orthodontic archwires in artificial saliva of various degrees of acidity10.1002/jbm.a.30340 ↗
30. The corrosion behavior of nickel titanium shape memory alloys10.1016/0010-938X(90)90004-O ↗
31. Susceptibility to delayed fracture of Ni–Ti superelastic alloy10.1016/S0921-5093(02)00201-0 ↗
32. Fracture of nickel–titanium superelastic alloy in sodium hypochlorite solution10.1016/j.msea.2003.10.320 ↗
33. The release of nickel form orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation10.1002/jbm.a.31097 ↗
34. Hydrogen absorption and thermal desorption behaviors of Ni–Ti superelastic alloy subjected to sustained tensile-straining test with hydrogen charging10.1016/j.scriptamat.2007.05.002 ↗
35. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni–Ti alloy also in presence of stress-induced martensite10.1002/(SICI)1097-4636(200007)51:1<47::AID-JBM7>3.0.CO;2-P ↗
36. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva10.1002/jbm.a.10463 ↗