Determination of corrosion rate of reinforcement with a modulated guard ring electrode; analysis of errors due to lateral current distribution
Source abstract
Abstract
The main source of errors in measuring the corrosion rate of rebars on site is a non-uniform current distribution between the small counter electrode (CE) on the concrete surface and the large rebar network. Guard ring electrodes (GEs) are used in an attempt to confine the excitation current within a defined area. In order to better understand the functioning of modulated guard ring electrode and to assess its effectiveness in eliminating errors due to lateral spread of current signal from the small CE, measurements of the polarisation resistance performed on a concrete beam have been numerically simulated. Effect of parameters such as rebar corrosion activity, concrete resistivity, concrete cover depth and size of the corroding area on errors in the estimation of polarisation resistance of a single rebar has been examined. The results indicate that modulated GE arrangement fails to confine the lateral spread of the CE current within a constant area. Using the constant diameter of confinement for the calculation of corrosion rate may lead to serious errors when test conditions change. When high corrosion activity of rebar and/or local corrosion occur, the use of the modulated GE confinement may lead to significant underestimation of the corrosion rate.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. S. Feliu, J. Gonzales, M.C. Andrade, V. Feliu, Corrosion 87, Paper No. 145, San Francisco, CA, March 1987
2. Elsener · 1994 · vol. 1 · 236
3. Sehgal · Corrosion NACE · 1992 · 48 · 87110.5006/1.3315888 ↗
4. Flis · Corrosion NACE · 1993 · 49 · 66110.5006/1.3316091 ↗
5. B. Elsener, O. Klinghoffer, T. Frolund, E. Rislund, Y. Schiegg, H. Boehni, Assessment of reinforcement corrosion by galvanostatic pulse technique, in: A. Blankvoll (Ed.), Proceedings of the International Conference on Repair of Concrete Structures, Svolvaer Norway, Norwegian Public Road Administration, 1997, pp. 391–400
6. H. Wojtas, Galvanostatic pulse measurements––rapid on site method for estimation of reinforcement corrosion in concrete constructions, in: Proceedings of the European Corrosion Congress Solution of Corrosion Problems Working Party 11: Corrosion in Concrete, Utrecht, 1998
7. S. Feliu, J.A. Gonzales, M.L. Escudero, S. Feliu Jr., M.C. Andrade, Possibilities of the Guard Ring for the confinement of the electrical signal in polarization measurements of reinforcements, Corrosion 89, Paper No. 623, New Orleans, April 1989
8. SHRP-S-324, Condition Evaluation of Concrete Bridges Relative to Reinforcement Corrosion, vol. 2, Method for Measuring the Corrosion Rate of Reinforcing Steel, National Research Council, Washington, DC, 1993
9. J. Rodrigez, L.M. Ortega, A.M. Garcia, L. Johansson, K. Petterson, On site corrosion rate measurements in concrete structures using a device developed and the Eureka Project EU-401, Conference Proceedings “Concrete Across Borders”, Denmark, 1994
10. H. Wojtas, COST 521: corrosion of steel in reinforced concrete structures, Final Reports of Single Projects 1997–2002, Final Workshop Luxembourg, 2002, pp. 141–147
11. H. Wojtas, Corrosion NACE, submitted for publication
12. Y. Liu, R.E. Weyers, Time to cracking for chloride-induced corrosion in reinforced concrete, in: C.L. Page, P.B. Bamforth, J.W. Figg (Eds.), Corrosion of Reinforcement in Concrete Construction, SCI, London, 1996, pp. 88–104
13. E. Vessikari, in: RILEM Proceedings 2000, PRO 18: Measurement and Interpretation of the On-Site Corrosion Rate, 2000, pp. 15–31
14. Law · British Corrosion Journal · 2000 · 35 · 13610.1179/000705900101501164 ↗