New insights into HCl-induced low-temperature corrosion in biomass- and waste-fired boilers
Source abstract
Abstract
This study investigates the risk of low-temperature corrosion on carbon steel tube surfaces located at the clean side of the flue gas channel downstream of a selective catalytic reduction (SCR) unit in a full-scale bubbling fluidized bed (BFB) boiler, where the HCl(g) concentration is typically very low (<5 ppm v ). Short- and long-term corrosion probe measurements, along with online deposit monitoring, were carried out in the flue gas channel to determine the causes of corrosion and establish safe material temperatures. To further investigate the results, laboratory tests were conducted in a quartz-tube furnace under simulated flue gas conditions. The results demonstrated that corrosion rates increased once the material surface temperature fell below 90 °C, with particularly severe attack evident at 80 and 70 °C. Notably, a considerable amount of chlorine was present in the corrosion products, indicating a high risk of chlorine-induced corrosion at cold-end surfaces, even at very low HCl(g) concentrations. Two potential corrosion mechanisms were identified, namely the absorption of HCl(g) into surface-adsorbed water monolayers above the water dew point, and the presence of corrosive NH 4 Cl(s,aq) on tube surfaces. HCl-induced corrosion was found to be the most likely mechanism. According to this mechanism, corrosion can occur even without bulk water condensation, and it depends on the local relative humidity (RH) at the steel surface. The findings collectively suggest that carbon steel surfaces on the clean side of the flue gas path should be maintained above approximately 90 °C (with an appropriate safety margin, depending on flue gas H 2 O(g) concentration) to mitigate the observed HCl-induced corrosion. A similar corrosion mechanism may also affect the dirty side of the flue gas path at similarly low temperatures. • In BFB boilers, cold-end surfaces are at risk of Cl-induced corrosion below ≈90 °C. • Corrosion is mainly due to HCl(g) adsorption into surface-adsorbed water monolayers. • Even <5 ppm v HCl(g) can cause corrosion on carbon steel under flue gas conditions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Chemical Looping and Thermochemical Processes · Corrosion Behavior and Inhibition · High-Temperature Coating Behaviors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Increasing supply for woody-biomass-based energy through wasted resources: insights from US private landowners10.3390/su15118667 ↗
2. Diversity of biomass usage pathways to achieve emissions targets in the European energy system
3. Efficiency of a coal-fired boiler in a typical thermal power plant
4. Enhancing steam boiler efficiency through comprehensive energy and exergy analysis: a review10.1016/j.psep.2024.01.102 ↗
5. Recovery boiler fireside deposits and plugging prevention
6. Understanding low-temperature corrosion in recovery boilers: risk of sulphuric acid dew point corrosion?
7. Hygroscopic properties of calcium chloride and its role on cold-end corrosion in biomass combustion10.1021/acs.energyfuels.9b02731 ↗
8. Research on formation mechanism of typical low-temperature fouling layers in biomass-fired boilers10.1016/j.csite.2022.102076 ↗
9. Deposit sintering in modern Kraft recovery boilers − The role of NaOH?
10. Biomass combustion technology development - It is all about chemical details10.1016/j.proci.2016.06.152 ↗
11. Low-temperature corrosion in large-scale biomass boilers
12. Low-temperature corrosion in co-combustion of biomass and solid recovered fuels10.1016/j.fuel.2016.03.096 ↗
13. Fouling of the flue gas cooler in a large-scale coal-fired power plant10.1016/j.applthermaleng.2017.02.048 ↗
14. Deposition and corrosion characteristics of liquid-solid droplets on tubular corrosion probes in desulfurized flue gas10.1016/j.engfailanal.2018.03.020 ↗
15. Low-temperature boiler corrosion and deposits—a literature review10.1021/ie50598a041 ↗
16. Impact of boiler load and limestone addition on SO3 and corrosive cold-end deposits in a coal-fired CFB boiler10.1016/j.fuel.2021.121313 ↗
17. Mechanism and modeling of the formation of gaseous alkali sulfates10.1016/j.combustflame.2004.08.014 ↗
18. Cold-end corrosion in biomass and waste incineration plants
19. Utilizing biomass and waste for power production - a decade of contributing to the understanding, interpretation and analysis of deposits and corrosion products10.1016/j.fuel.2004.08.026 ↗
20. L. Lindau and B. Goldschmidt, “Low-temperature corrosion in bark fuelled, small boilers (A technical report).” Värmeforsk Service AB, Stockholm, 2002.
21. “Corrosion caused by dew point and deliquescent salts in the boiler and flue gas cleaning,”
22. Cold-end corrosion caused by hygroscopic ammonium chloride in thermal conversion of biomass and waste10.1016/j.fuel.2023.128061 ↗
23. Cold-end corrosion in biomass combustion – role of calcium chloride in the deposit10.1016/j.fuel.2023.128344 ↗
24. A novel methodology for monitoring low-temperature corrosion caused by hygroscopic salts using linear polarization resistance10.1016/j.electacta.2024.143827 ↗
25. Phase transition dynamics of single optically trapped aqueous potassium carbonate particles10.1039/C8CP00599K ↗
26. Down-time corrosion in boilers10.1016/j.fuproc.2015.10.009 ↗
27. Corrosion in the flue gas cleaning system of a biomass-fired power plant10.1007/s11668-017-0238-y ↗
28. Field study on the corrosion and ash deposition of low-temperature heating surface in a large-scale coal-fired power plant10.1016/j.fuel.2017.06.120 ↗
29. Desulfurized flue gas corrosion coupled with deposits in a heating boiler10.1016/j.corsci.2017.11.009 ↗
30. Experimental study on dew point corrosion characteristics of the heating surface in a 65 t/h biomass-fired circulating fluidized bed boiler10.1016/j.applthermaleng.2015.10.151 ↗
31. T. Laurén, “Methods and instruments for characterizing deposit buildup on heat exchangers in combustion plants,” Licentiate thesis, Laboratory of Inorganic Chemistry, Åbo Akademi University, Finland, 2007.
32. Low-temperature corrosion in a BFB boiler firing biomass and waste streams – online measurement technique for monitoring deposit corrosivity
33. P.R. Roberge, “Handbook of corrosion engineering (third edition),” McGraw-Hill Education, ISBN: 9781260116977, 2019.
34. Influence of operating conditions on ammonium bisulfate deposition in the rotary air preheater of coal-fired power plants10.2298/TSCI180524213W ↗
35. S. Carroll, J. Rard, M. Alai, and K. Staggs, “Brines formed by multi-salt deliquescence.” Lawrence Livermore National Laboratory (LLNL), pp. 1–25, 2005. doi: https://doi.org/10.2172/928172.10.2172/928172 ↗
36. Reprint of: FactSage thermochemical software and databases, 2010–2016
37. Effect of relative humidity on ammonium chloride corrosion in refineries10.5006/1.3590331 ↗
38. Leygraf · 2016
39. Marine atmospheric corrosion of carbon steel: a review10.3390/ma10040406 ↗
40. Evolution of the adsorbed water layer structure on silicon oxide at room temperature10.1021/jp053042o ↗
41. Corrosion of stainless steels and corrosion protection strategies in the semiconductor manufacturing industry: a review10.1515/corrrev-2023-0051 ↗
42. Corrosion of a 316L stainless steel in a gaseous environment polluted with HCl: mechanism10.1002/maco.202011883 ↗
43. New hydrometallurgical approach to obtain uniform antiferromagnetic ferrous chloride cubes from waste tin cans10.1007/s10854-020-05048-1 ↗
44. Obtention and characterization of ferrous chloride FeCl2·4H2O from water pickling liquors10.3390/ma14174840 ↗
45. Desiccated storage of chloride-contaminated archaeological iron objects10.1179/sic.2005.50.4.241 ↗
46. Unforeseen high temperature and humidity stability of FeCl3 intercalated few layer graphene10.1038/srep07609 ↗
47. “Calcul Des diagrammes de phases des systemes binaires H2O–MCln (M=Mg2+, Fe2+, Fe3+),”10.1023/A:1010109500891 ↗
48. On the atmospheric corrosion of metals which are covered with thin electrolyte layers—I. Verification of the experimental technique10.1016/0010-938X(90)90032-Z ↗
49. On the atmospheric corrosion of metals which are covered with thin electrolyte layers—II. Experimental results10.1016/0010-938X(90)90033-2 ↗
50. On the atmospheric corrosion of metals which are covered with thin electrolyte layers-iii. the measurement of polarisation curves on metal surfaces which are covered by thin electrolyte layers10.1016/0010-938X(90)90034-3 ↗
51. FT-IR study of water adsorption on aluminum oxide surfaces10.1021/la026208a ↗
52. Facet-engineered TiO 2 nanomaterials reveal the role of water–oxide interactions in surface protonic conduction10.1039/D1TA06075A ↗
53. Study on air preheater corrosion problem of CFB biomass directed-fired boiler in Zhanjiang biomass power plant10.4028/www.scientific.net/AMM.291-294.294 ↗
54. Predicting dew points of acid gases
55. Vapor pressure of pure substances. Organic and inorganic compounds10.1021/ie50448a022 ↗
56. The corrosion of iron and zinc by atmospheric hydrogen chloride10.1016/0010-938X(93)90004-Z ↗
57. Formation and corrosivity of CaCl2 in the cold end of biomass- and waste-fired boilers