journal article·2006-07

On-line corrosion monitoring in geothermal district heating systems. I. General corrosion rates

S. Richter, L.R. Hilbert, R.I. Thorarinsdottir

Corrosion Science· Volume 48· Issue 7
Publisher page

Abstract

General corrosion rates in the geothermal district heating systems in Iceland are generally low, of the magnitude 1 μm/y. The reason is high pH (9.5), low-conductivity (200 μm/y) and negligible dissolved oxygen. The geothermal hot water is either used directly from source or to heat up cold ground water. The fluid naturally contains sulphide, which helps keeping the fluid oxygen-free but complicates the electrochemical environment. In this research on-line techniques for corrosion monitoring were tested and evaluated in this medium. Electrochemical methods worked well as long as frequency was kept low but ER worked better if oxygen was present.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Concrete Corrosion and Durability · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. National Energy Authority, Energy in Iceland. Historical Perspective, Present Status, Future Outlook, February 2004.
2. Nature of sulphides and their corrosive effect on Ferrous metals: a review10.1179/000705975798320701 ↗
3. Electrochemical polarization, I. A theoretical analysis of the shape of polarization curves10.1149/1.2428496 ↗
4. Corrosion monitoring using polarisation resistance measurements10.1179/000705976798320070 ↗
5. On the so-called linear polarization method for measurement of corrosion rates10.5006/0010-9312-27.10.434 ↗
6. R.I. Thorarinsdottir, Corrosion of Copper and Copper Alloys in Geothermal District Heating Water Containing Sulphide, Ph.D. Thesis, The Technical University of Denmark, 2000.
7. ISO 8407, Corrosion of metals and alloys—Removal of corrosion products from corrosion test specimens, 1991.
8. Differential ER-technology for measuring degree of accumulated corrosion as well as instant corrosion rate
9. Polarization resistance method for determination of instantaneous corrosion rates10.5006/1.3280536 ↗
10. An impedance interpretation of small amplitude cyclic voltammetry. I. Theoretical analysis for a resistive–capacitive system10.1149/1.2131693 ↗
11. Kelly · 2003
12. Jones · 1996
13. S. Richter, R.I. Thorarinsdottir, On-line monitoring of corrosion in low-corrosive environment, in: Proceedings 13, Scandinavian Corrosion Congress, Reykjavik, Iceland, 2004.
14. B.A. Boukamp, Equivalent circuit (EQUIVCRT.PAS), Users manual, University of Twente, 1989.