journal article·2013-11

Study of relative color stability and corrosion resistance of commercial copper alloys exposed to hand contact and synthetic hand sweat

N. Fredj, J.S. Kolar, D.M. Prichard, T.D. Burleigh

Corrosion Science· Volume 76
Publisher page

Abstract

Abstract Commercial purity copper and four commercial copper alloys were studied to determine their color stability during prolonged hand contact and their corrosion resistance in synthetic sweat containing 0.8% sodium chloride and 3% acetic acid. The hand baton test showed that alloys C752 and C706 with high nickel content remained shiny after two years of exposure to hand contact whereas C110 and alloys C260 and C510 became dark and dull. Glancing Angle X-ray Diffraction showed the presence of cuprous oxide Cu 2 O on the copper alloys with a thickness between 50 and 230 nm, as determined by chronopotentiometry. The dark appearance of C110, C260 and C510 after hand contact was the consequence of the reflection of light from a rough and porous surface, as verified by Scanning Electron Microscopy. The nickel in the copper alloys kept the alloys shiny with good color stability by keeping a smoother surface. Electrochemical Impedance Spectroscopy showed that copper C110 and brass C260 had the best corrosion resistance, followed by C510 and alloys C706 and C752 had the lowest corrosion resistance, all tested in synthetic sweat. The nickel containing alloys corroded approximately 40 times faster than the C110 in the synthetic sweat. This suggests that the color stable surface of the Cu–Ni samples on the hand baton was the result of higher corrosion rates in hand sweat rather than better corrosion resistance. SEM studies of the samples after immersion, however, revealed very different surfaces and microstructures compared to the hand baton test. The laboratory test protocol could be improved by incorporating cyclic tests (wet and dry) and adding a rubbing component to better mimic actual hand contact.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Recycling and Waste Management Techniques · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Control and mitigation of healthcare-acquired infections: designing clinical trials to evaluate new materials and technologies
2. Potential use of copper surfaces to reduce survival of epidemic meticillin-resistant staphylococcus aureus in the healthcare environment10.1016/j.jhin.2005.12.008 ↗
3. The antimicrobial activity of copper and copper alloys against nosocomial pathogens and mycobacterium tuberculosis isolated from healthcare facilities in the western cape: an in-vitro study10.1016/j.jhin.2007.10.009 ↗
4. H.T. Michels, J.P. Noyce, S.A. Wilks, C.W. Keevil, Antimicrobial Effects of Cast Copper Alloy Surfaces on the Bacterium E.coli 0157:H7, in: American Foundry Society Transactions, Schaumburg, IL USA, 2005, pp. 1–13.
5. Survival of clostridium difficile on copper and steel: futuristic options for hospital hygiene10.1016/j.jhin.2007.11.011 ↗
6. Potential for preventing spread of fungi in air-conditioning systems constructed using copper instead of aluminium
7. Metal corrosion by chloride in sweat10.1111/j.1365-2133.1976.tb00843.x ↗
8. Corrosion of metals by human sweat and its prevention10.1016/S0010-938X(72)91242-5 ↗
9. ‘Rusters’. The corrosive action of palmar sweat: II physical and chemical factors in palmar hyperhidrosis.10.2340/0001555559139143 ↗
10. Characterization of the corrosion layer of copper-nickel alloys in a synthetic sweat medium by FTMS and LAMMA laser microprobes10.1016/S0169-4332(97)00400-5 ↗
11. An XPS and AES study of the free corrosion of Cu-, Ni-, and Zn-based alloys in synthetic sweat10.1016/S0010-938X(98)00141-3 ↗
12. Metal ion release and surface composition of the Cu–18Ni–20Zn nickel-silver during 30days immersion in artificial sweat10.1016/j.apsusc.2007.06.049 ↗
13. Study of Cu–18Ni–20Zn nickel silver and Cu-based alloys in artificial sweat and physiological solution10.1016/j.electacta.2007.04.105 ↗
14. Respiratory cancer in Welsh nickel refiners: which nickel compounds are responsible?
15. The problem of latency in the development of tumors following exposure to nickel compounds10.1016/0048-9697(94)90395-6 ↗
16. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro10.1002/(SICI)1097-4636(19990605)45:3<251::AID-JBM13>3.0.CO;2-5 ↗
17. ISO, Textiles – Tests for colour fastness, in: Part E04: Colour fastness to perspiration, 2008.
18. AATCC, Colorfastness to Perspiration, in: American Association of Textile Chemists and Colorists, 2002.
19. British, Artificial Sweat, BS EN 1811:1999, in: British Standard, 1999.
20. Dissolution of materials in artificial skin surface film liquids10.1016/j.tiv.2006.05.011 ↗
21. Determination of silver nanoparticle release from antibacterial fabrics into artificial sweat10.1186/1743-8977-7-8 ↗
22. Copper Oxide Films
23. Transpassive dissolution of copper and rapid formation of brilliant colored copper oxide films10.1149/1.3551525 ↗
24. F. Karlsruhe, , Inorganic Crystal Structure Database (ICSD), in, FIZ Karlsruhe Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany, 2012.
25. Formulation and satability of a novel artificial human sweat under conditions of storage and use10.1016/j.tiv.2010.06.016 ↗