On-line corrosion monitoring in geothermal district heating systems. II. Localized corrosion
Source abstract
Abstract
Abstract Corrosion monitoring in district heating systems has traditionally been performed by using off-line methods, such as weight loss. The disadvantage is that the method is very slow, especially in low-corrosive environments, and that it only provides information about the past corrosion (accumulated over period of time). The purpose of the work is to test on-line monitoring methods in geothermal hot water in the district heating system in Reykjavik, Iceland. Geothermal water poses certain problems with regards to corrosion monitoring due to low conductivity, high pH and the presence of sulphide. These conditions make the geothermal environment low corrosive. However, a quality control is needed, especially since the sulphide causes the steel pipes to be more vulnerable towards localized corrosion. The methods used in this study were: linear polarization resistance (LPR), harmonic analysis (HA), electrochemical noise (EN) and zero resistance ammetry (ZRA). The Pitting Factor was measured with EN and showed promising results for measuring-localized corrosion on-line. A crevice corrosion cell also gave good results but had a low lifetime. However, the results of a galvanic corrosion cell (Fe/Cu) proved more difficult to interpret since they were dependent both on the dissolved oxygen and the sulphide level.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Integrity and Reliability Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Investigation of corrosion attacks of copper in heating systems (In: German: Untersuchungen über das Korrosionsverhalten von Kupfer im Heizungsanlagenbereich)
2. K. Nielsen, O.B. Sørensen, F. Yding, Corrosion of copper pipes and brazing metals in district heating systems, Scandinavian Corrosion Congress, Helsinki, Finland, 1978.
3. R.I. Thorarinsdottir (Ed.), Project no. 00071, Monitoring corrosion in district heating systems, Final Report, Nordic Innovation Centre, 2004.
4. T. Hemmingsen, The Effect of Sulphite on Corrosion, Ph.D. thesis, University of Bergen, 1992.
5. L.V. Nielsen, The Effect of Cathodic Protection and Microbiological Activity on Hydrogen-Related Cracking in Steel, Ph.D. thesis, Technical University of Denmark, 1995.
6. L.R. Hilbert, Monitoring Microbially Influenced Corrosion, Ph.D. thesis, Technical University of Denmark, 2000.
7. On-line corrosion monitoring in geothermal district heating systems. I. General corrosion rates10.1016/j.corsci.2005.06.019 ↗
8. Dvay · Acta Chim. Acad. Sci. Hung. · 1979 · 183
9. A. Einarsson, E. Gunnlaugsson, Corrosion in geothermal district heating systems, in: Cold Climate HVAC, Reykjavik, Iceland, 1997.
10. A. Pehkonen, O. Forsen, K. Karkkainen, J. Leino, Development of electrochemical measurement system for corrosion monitoring in district heating systems, in: The Proceedings of Eurocorr 2003, Budapest, Hungary, 2003.
11. S. Richter, R.I. Thorarinsdottir, L.R. Hilbert, A. Pehkonen, On-line corrosion monitoring in district heating systems, in: The Proceedings of the 9th International Symposium on District Heating and Cooling, Helsinki, Finland, 2004.
12. R.I. Thorarinsdottir, Corrosion of Copper and Copper Alloys in Geothermal District Heating Water Containing Sulphide, Ph.D. thesis, Technical University of Denmark, 2000.
13. R.I. Thorarinsdottir, Taering álsýna í hitaveitukerfum, Technical report 02-09, The Icelandic Building Research Institute, 2002.
14. L. Norskov, S. Richter, R.I. Thorarinsdottir, Comparative studies of electrochemical methods in sulphide containing water distribution systems, in: The Proceedings of Eurocorr 2003, Budapest, Hungary.
15. Electrochemical tests