Effect of fretting regimes on the fretting corrosion behavior of stainless steel in artificial crevices
Source abstract
Abstract
Fretting crevice corrosion at the fastening interfaces of stainless-steel products is an unavoidable issue in the medical, marine, and nuclear industries. In this study, the effects of the fretting regimes on the fretting corrosion in artificial crevices were investigated, and the results showed that fretting initiated severe corrosion inside the crevice under the stick regime. Under the stick–slip and slip regimes, the volume loss was dominated by fretting corrosion, without initiating crevice corrosion.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical stress and fatigue analysis · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Projections and epidemiology of revision hip and knee arthroplasty in the United States to 2040-206010.1016/j.artd.2023.101152 ↗
2. Risk factors associated with early complications of revision surgery for head-neck taper corrosion in metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2018.05.046 ↗
3. Diagnostic accuracy of MRI with metal artifact reduction for the detection of periprosthetic joint infection and aseptic loosening of total hip arthroplasty10.1016/j.ejrad.2020.109253 ↗
4. Biomaterials in orthopaedics10.1098/rsif.2008.0151 ↗
5. Corrosion of metallic biomaterials: a review10.3390/ma12030407 ↗
6. Outcome of re-revision surgery for adverse local tissue reaction in metal-on-polyethylene and metal-on-metal total hip arthroplasty10.1016/j.arth.2020.02.006 ↗
7. Revealing the corrosion product films of ion-implanted biodegradable Zn–Cu alloys10.1016/j.corsci.2022.110814 ↗
8. Sensitivity and specificity of metal ion level in predicting adverse local tissue reactions due to head-neck taper corrosion in primary metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2018.04.007 ↗
9. Long-term results of bipolar hemiarthroplasty for osteoarthritis of the hip and idiopathic osteonecrosis of the femoral head10.1007/s00776-008-1238-2 ↗
10. Titanium, chromium and cobalt ions modulate the release of bone-associated cytokines by human monocytes/macrophages in vitro10.1016/0142-9612(96)00072-5 ↗
11. Fretting and corrosion at the backside of modular cobalt chromium acetabular inserts: a retrieval analysis10.1016/j.arth.2016.09.038 ↗
12. Corrosion and fretting of a modular hip system: a retrieval analysis of 60 rejuvenate stems10.1016/j.arth.2015.03.010 ↗
13. Fretting in prosthetic devices related to human body10.1016/j.triboint.2009.04.007 ↗
14. Fretting and corrosion damage of retrieved dual-mobility total hip arthroplasty systems10.1016/j.arth.2019.02.008 ↗
15. Internal leakage of plate heat exchangers caused by cooperation of pitting, crevice corrosion, and fretting10.1016/j.engfailanal.2018.10.007 ↗
16. Crevice corrosion of stainless steels: II. Experimental studies10.1179/000705978798276258 ↗
17. Crevice corrosion of stainless steels: I. A mathematical model10.1179/000705978798358671 ↗
18. A discussion on evaluation criteria for crevice corrosion of various stainless steels10.1016/j.jmst.2020.04.017 ↗
19. A new experimental method to simulate dynamic crevice corrosion in modular hip arthroplasty10.1016/j.corsci.2021.109704 ↗
20. The role of oxygen on the stability of crevice corrosion10.1149/1.1470655 ↗
21. Corrosion at contact with glass10.1039/tf9343000417 ↗
22. Initiation modeling of crevice corrosion in 316L stainless steels10.1016/S0924-0136(00)00462-3 ↗
23. The initiation of crevice corrosion in stainless steels10.1016/S0010-938X(97)00050-4 ↗
24. Role of metastable pitting in crevices on crevice corrosion stabilization in alloys 625 and 2210.5006/1.3278202 ↗
25. The influence of the crevice induced IR drop on polarization measurement of localized corrosion behavior of 316L stainless steel10.1016/j.corsci.2019.04.030 ↗
26. Effects of crevice geometry on corrosion behavior of 304 stainless steel during crevice corrosion in high temperature pure water10.1016/j.corsci.2016.04.049 ↗
27. Crevice corrosion of U75V high-speed rail steel with varying crevice gap size by in-situ monitoring10.1016/j.jmrt.2021.12.116 ↗
28. Crevice corrosion behavior of X70 steel in NaCl solution with different pH10.1016/j.corsci.2021.109310 ↗
29. Crevice corrosion of steel rebar in chloride-contaminated concrete10.1016/j.conbuildmat.2021.123587 ↗
30. Crevice corrosion behaviors of CoCrMo alloy and stainless steel 316L artificial joint materials in physiological saline10.1016/j.corsci.2021.110075 ↗
31. Role of protein in crevice corrosion of CoCrMo alloy: An investigation using wire beam electrodes10.1016/j.corsci.2023.111028 ↗
32. The crevice corrosion behaviour of stainless steel in sodium chloride solution10.1016/j.corsci.2011.08.012 ↗
33. Corrosion and fretting of a modular hip system: a retrieval analysis of 60 rejuvenate stems10.1016/j.arth.2015.03.010 ↗
34. Bio-tribocorrosion mechanisms in orthopaedic devices: Mapping the micro-abrasion–corrosion behaviour of a simulated CoCrMo hip replacement in calf serum solution10.1016/j.wear.2014.04.016 ↗
35. Analysis of energy dissipation in fretting corrosion experiments with materials used as hip prosthesis10.1016/j.wear.2012.07.014 ↗
36. Fretting crevice corrosion of 316 L stainless steel in physiological phosphate buffered saline: Load, potential and alloy counterface effects10.1016/j.triboint.2021.107198 ↗
37. Fretting initiated crevice corrosion of 316LVM stainless steel in physiological phosphate buffered saline: potential and cycles to initiation10.1016/j.actbio.2019.07.051 ↗
38. Corrosion behaviour of CoCrMo implant alloy during fretting in bovine serum10.1016/j.corsci.2004.09.003 ↗
39. Highly porous Ti as a bone substitute: triboelectrochemical characterization of highly porous Ti against Ti alloy under fretting-corrosion conditions10.1016/j.corsci.2021.109696 ↗
40. Fretting-corrosion behavior in hip implant modular junctions: the influence of friction energy and pH variation10.1016/j.jmbbm.2016.05.024 ↗
41. Interfacial compliance, energy dissipation, frequency effects, and long-term fretting corrosion performance of Ti-6Al-4V/CoCrMo interfaces10.1002/jbm.a.37299 ↗
42. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
43. Stability loss of the cemented stem of hip prosthesis due to fretting corrosion fatigue10.24874/ti.2017.39.04.13 ↗
44. In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: debris generation, chemistry and distribution10.1016/j.actbio.2020.07.052 ↗
45. Study of fretting-initiated crevice corrosion and crevice corrosion affected fretting of stainless steel10.1016/j.corsci.2023.111586 ↗
46. Compliant interfaces and fretting corrosion of modular taper junctions in total hip implants: the micromechanics of contact10.1016/j.triboint.2020.106437 ↗
47. Fretting crevice corrosion of 316 L stainless steel in physiological phosphate buffered saline: load, potential and alloy counterface effects10.1016/j.triboint.2021.107198 ↗
48. One dimensional wormhole corrosion in metals10.1038/s41467-023-36588-9 ↗