journal article·2025-07Open access

Pitting corrosion mechanisms of Ti-Cu-(Pd-) based metallic glasses in simulated physiological solution

Viktoriia Shtefan, Nora Fernández Navas, Ivan Kaban, Martin Hantusch, Annett Gebert

Corrosion Science· Volume 251

Abstract

Ti-based bulk metallic glasses with very high strength-to-stiffness ratio are promising candidates for biomedical applications. However, their substantial Cu contents cause biocompatibility issues regarding cytocompatibility and corrosion resistance. This work focuses on the analysis of chloride ion-induced pitting corrosion processes of two prominent glassy alloys under free corrosion and anodic polarisation conditions in phosphate-buffered saline (PBS) solution (pH 7.4) at 37 °C. The Ti 47 Zr 7.5 Cu 38 Fe 2.5 Sn 2 Si 1 Ag 2 glass demonstrates high susceptibility to passive film degradation and breakdown during long-term testing under OCP condition and upon anodic polarisation (LVA). Electrochemical Impedance Spectroscopy (EIS) indicates the formation of a porous, non-continuous surface film with low resistance. The shape of the anodic polarisation by charging curves (APCC) indicates a limited ability for pit repassivation. The Ti 40 Zr 10 Cu 34 Pd 14 Sn 2 glass exhibits higher resistance to pitting corrosion, which alters the nature of surface degradation. Surface state analysis by means of SEM, EDX, XRD and XPS reveal that the corrosion products within the pits and their surroundings are enriched in Cu, Zr and Pd. Mechanisms for the development of pitting corrosion for the two alloys, including nanoligament formation and advanced degradation, are proposed and especially the role of Cu and Pd therein is discussed. These findings provide valuable insights into the corrosion mechanisms of Ti-Cu based glassy alloys and serve as a base for developing corrosion resistance strategies. • Cu plays a significant role in the nucleation and growth of closed pits. • Alloying Ti-Cu-based metallic glasses with Pd enhances oxide film passivation. • Pit initiation, growth, repassivation and degradation rely on passive film properties. • Pit propagation involves ligament formation and follows the dealloying mechanism.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metallic Glasses and Amorphous Alloys · Pigment Synthesis and Properties · Material Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. Distinctive features and fabrication routes of metallic-glass systems designed for different engineering applications: a review10.3390/coatings13101689 ↗
2. Recent development in the application of bulk metallic glasses10.1016/j.jmst.2022.05.028 ↗
4. Review on biocompatibility and prospect biomedical applications of novel functional metallic glasses10.3390/jfb13040245 ↗
5. Bulk metallic glasses for healthcare: state of the art and prospects for the future
6. Fine-tuning effect of direct laser interference patterning on the surface states and the corrosion behavior of a biomedical additively manufactured beta Ti alloy10.1016/j.corsci.2023.111230 ↗
7. On the potential of bulk metallic glasses for dental implantology: case study on Ti40Zr10Cu36Pd1410.3390/ma11020249 ↗
8. Effect of minor Sn additions on the formation and properties of TiCuZrPd bulk glassy alloy10.2320/matertrans.M2011281 ↗
9. A new Ti-based bulk glassy alloy with potential for biomedical application10.1016/j.msea.2007.01.044 ↗
10. New Ti-based Ti-Cu-Zr-Fe-Sn-Si-Ag bulk metallic glass for biomedical applications10.1016/j.jallcom.2014.07.021 ↗
11. Selective laser melting of a Ti-based bulk metallic glass10.1016/j.matlet.2017.10.130 ↗
12. Ti-Cu-Zr-Fe-Sn-Si-Ag-Pd bulk metallic glasses with potential for biomedical applications10.1007/s11661-021-06183-y ↗
13. Characterization of surface properties, osteoblast cell culture in vitro and processing with flow-viscosity of Ni-free Ti-based bulk metallic glass for biomaterials10.1299/jbse.4.384 ↗
14. Designing biocompatible Ti-based metallic glasses for implant applications10.1016/j.msec.2012.11.015 ↗
15. In vitro and in vivo studies on Ti-based bulk metallic glass as potential dental implant material10.1016/j.msec.2013.04.038 ↗
16. Rapid screening of potential metallic glasses for biomedical applications10.1016/j.msec.2013.07.006 ↗
17. Electrochemical surface nanostructuring of Ti47Cu38Fe2.5Zr7.5Sn2Si1Ag2 metallic glass for improved pitting corrosion resistance10.1002/adem.202302206 ↗
18. Catastrophic stress corrosion failure of Zr-base bulk metallic glass through hydrogen embrittlement10.1016/j.corsci.2019.06.012 ↗
19. Stress corrosion cracking and bioactivity of Ti-based bulk metallic glass10.1016/j.jallcom.2013.11.153 ↗
20. Ultrasonic fatigue of Ti40Zr10Cu34Pd14Sn2 glassy alloy10.4236/ojmetal.2014.43007 ↗
21. Corrosion-fatigue studies of the Zr-based Vitreloy 105 bulk metallic glass10.1016/j.msea.2007.03.106 ↗
22. Modification of structural, mechanical, corrosion and biocompatibility properties of Ti40Zr10Cu36Pd14 metallic glass by minor Ga and Sn additions10.1016/j.jallcom.2023.168776 ↗
23. Formation and properties of biocompatible Ti-based bulk metallic glasses in the Ti–Cu–Zr–Fe–Sn–Si–Ag system10.1016/j.jnoncrysol.2021.121060 ↗
24. Acid treatments of Ti-based metallic glasses for improving corrosion resistance in implant applications10.3390/met14020241 ↗
25. Corrosion and related mechanical properties of bulk metallic glasses10.1557/jmr.2007.0051 ↗
26. Comparing the pitting corrosion behavior of prominent Zr-based bulk metallic glasses10.1557/jmr.2014.371 ↗
27. Characterization of corrosion phenomena of Zr-Ti-Cu-Al-Ni metallic glass by SEM and TEM10.1016/j.matchar.2010.06.013 ↗
28. Interactions between mechanically generated defects and corrosion phenomena of Zr-based bulk metallic glasses10.1016/j.actamat.2011.12.044 ↗
29. Pitting corrosion of bulk glass-forming zirconium-based alloys10.1016/j.jallcom.2004.01.043 ↗
30. Differences in pitting growth kinetics between Zr60Ni25Al15 and Zr60Cu25Al15 metallic glasses exposed to a 0.6 M NaCl aqueous solution10.1016/j.corsci.2017.09.007 ↗
31. Formation and properties of Ti-based Ti-Zr-Cu-Fe-Sn-Si bulk metallic glasses with different (Ti + Zr)/Cu ratios for biomedical application10.1016/j.intermet.2016.01.007 ↗
32. Corrosion resistance of titanium and its alloys10.1149/1.2428023 ↗
33. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments10.1016/j.biomaterials.2004.07.022 ↗
34. Schweitzer · 2006
35. In situ synchrotron X-Ray diffraction characterization of corrosion products of a Ti-based metallic glass for implant applications10.1002/adhm.201800338 ↗
36. Effect of alloying elements on the microstructure and corrosion behavior of TiZr-based bulk metallic glasses10.1016/j.corsci.2020.108854 ↗
37. The high score suite10.1017/S0885715614000840 ↗
38. International Centre for Diffraction Data. 〈https://www.icdd.com〉, 2024 (accessed 29 July 2024), (n.d.).
39. Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices
40. An assessment of ASTM F 2129 electrochemical testing of small medical implants - lessons learned
41. Marcus · 2011
42. Electrochemical aspects of pitting corrosion10.1016/S0010-938X(67)80073-8 ↗
43. 2018
44. The analysis of electrode impedances complicated by the presence of a constant phase element10.1016/S0022-0728(84)80324-1 ↗
45. Determination of effective capacitance and film thickness from constant-phase-element parameters10.1016/j.electacta.2009.10.065 ↗
46. Growth and crystallization of titanium oxide films at different anodization modes10.1149/2.070306jes ↗
47. Electrochemical behaviour of Ti and Ti-6Al-4V alloy in phosphate buffered saline solution10.3390/ma14247495 ↗
48. Formation, mechanical properties and corrosion resistance of Ti-Pd base glassy alloys10.1016/j.jnoncrysol.2007.10.025 ↗
49. Effect of palladium on the corrosion behavior of titanium10.1016/j.corsci.2003.10.003 ↗
50. Porous metallic structures by dealloying amorphous alloys10.1016/j.jallcom.2023.172417 ↗
51. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
52. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
53. Novel approach using EIS to study flow accelerated pitting corrosion of AA5083-H321 aluminum-magnesium alloy in NaCl solution10.1007/s10800-009-9867-5 ↗
54. The study of the passivation process by the electrode impedance analysis
55. How the multi-phase microstructure of a novel tool steel determines its corrosion behaviour in sulphuric acids10.1016/j.corsci.2024.112091 ↗
56. Diskussion über die ursache und stabilität der lochfrasskorrosion in zusammenhang mit dem „alles-oder-nichts“-gesetz "-gesetz der passivität und einem kinetischen modell10.1016/S0010-938X(63)80005-0 ↗
57. Über den passiven zustand der nichtrostenden legierungen in gegenwart von chlorionen10.1515/zpch-1960-21503 ↗
58. The structural chemistry of titanyl oligomers and polymers10.1016/j.ccr.2023.215467 ↗
59. Presentation of an atlas of chemical and electrochemical equilibria in the presence of a gaseous phase10.4028/www.scientific.net/MSF.251-254.143 ↗
60. Catastrophic stress corrosion failure of Zr-base bulk metallic glass through hydrogen embrittlement10.1016/j.corsci.2019.06.012 ↗