Design of new β-type Ti alloys with outstanding corrosion and wear resistance for dental application
Source abstract
Abstract
β-type Ti alloys have drawn extensive attention as potential metallic implants. In this work, the microstructure, corrosion behavior, and wear performance of Ti−17.3 Nb−1.8Fe (TNF) and Ti−22 Nb−30Zr−4Cr (TNZC) biomedical alloys were experimentally investigated, and CP−Ti and Ti6Al4V alloy were also used for comparisons. TNF and TNZC alloys after solution treatment at 1273 K showed a single β phase. It was found that TNF and TNZC alloys revealed better corrosion resistance than CP−Ti and Ti6Al4V alloy in different artificial saliva containing 0.15 wt% NaF with the pH values of 3.9 and 5.7, which could be ascribed to the formation of a double-layer passive film composed of multiple species oxides. Moreover, TNF and TNZC alloys exhibited higher wear resistance compared with CP−Ti and Ti6Al4V alloy, whose wear mechanism was adhesive wear and abrasive wear. The present results show that TNF and TNZC alloys are nice candidates for dental application.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Corrosion Behavior and Inhibition · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (75)
Show source-provided references
1. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
2. A review on biomedical titanium alloys: Recent progress and prospect10.1002/adem.201801215 ↗
3. Comprehensive review on alloy design, processing, and performance of β Titanium alloys as biomedical materials10.1080/09506608.2020.1735829 ↗
4. Metallic materials for biomedical applications: laboratory and clinical studies10.1351/PAC-CON-10-07-09 ↗
5. Tuning microstructure and enhancing corrosion property of Ti-6Al-3Nb-2Zr-1Mo alloy through electron beam surface melting10.1016/j.corsci.2022.110520 ↗
6. Binary titanium alloys as dental implant materials-a review10.1093/rb/rbx027 ↗
7. Application of titanium and titanium alloys to fixed dental prostheses10.1016/j.jpor.2019.04.011 ↗
8. A more defective substrate leads to a less defective passive layer: enhancing the mechanical strength, corrosion resistance and anti-inflammatory response of the low-modulus Ti-45Nb alloy by grain refinement10.1016/j.actbio.2021.02.045 ↗
9. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells
10. Measurement of the dynamic Young's modulus of porous titanium and Ti6Al4V10.1007/s10853-007-1532-y ↗
11. Microstructure, mechanical properties and corrosion behaviors of biomedical Ti-Zr-Mo-xMn alloys for dental application10.1016/j.corsci.2019.108195 ↗
12. investigation of the Young's modulus and its application to the development of a novel Ti-Nb-Zr-Cr bio-alloy
13. Microstructure characterization and biocompatibility behaviour of TiNbZr alloy fabricated by powder metallurgy10.1088/2053-1591/ab58a5 ↗
14. Development of low-Young's modulus Ti-Nb-based alloys with Cr addition10.1007/s10853-019-03457-0 ↗
15. Microstructure and corrosion resistance of novel b-type titanium alloys manufactured by selective laser melting10.1016/j.jmrt.2022.07.021 ↗
16. Surface properties and mechanical performance of Ti-based dental materials: comparative effect of valve alloying elements and structural defects10.1007/s11661-021-06515-y ↗
17. Corrosion resistance of β-phase titanium alloys under simulated inflammatory conditions: exploring the relevance of biocompatible alloying elements10.1016/j.corsci.2023.111271 ↗
18. High-throughput exploration of composition-dependent elasto-plastic and diffusion properties of refractory multi-element Ti-Nb-Zr-W alloys10.1016/S1003-6326(23)66287-9 ↗
19. High-throughput determination of mechanical and diffusion properties in the Ti-Nb-Fe alloys10.1016/j.calphad.2022.102497 ↗
20. High-throughput studies and machine learning for design of β titanium alloys with optimum properties10.1016/S1003-6326(24)66602-1 ↗
21. Understanding the enhanced corrosion performance of two novel Ti-based biomedical high entropy alloys10.1016/j.jallcom.2023.170343 ↗
22. Development of binary and ternary titanium alloys for dental implants10.1016/j.dental.2017.07.013 ↗
23. Influence of fluoride content and pH on corrosion and tribocorrosion behaviour of Ti13Nb13Zr alloy in oral environment10.1016/j.jmbbm.2015.05.008 ↗
24. Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion10.1002/jbm.b.32735 ↗
25. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH–an electrochemical study10.1111/j.1600-0501.2011.02265.x ↗
26. Corrosion behavior of Ti-39Nb alloy for dentistry10.1016/j.msec.2015.07.029 ↗
27. Toumelin-Chemla, Influence of pH and fluoride concentration on titanium passivating layer: stability of titanium dioxide10.1016/S0039-9140(00)00592-0 ↗
28. Corrosion behaviour of a wrought Ti-6Al-3Nb-2Zr-1Mo alloy in artificial seawater with various fluoride concentrations and pH values10.1016/j.matdes.2022.110416 ↗
29. Tribocorrosion behavior of hot pressed CoCrMo alloys in artificial saliva10.1016/j.triboint.2016.02.007 ↗
30. Assessment of microstructure, nanomechanical and tribological properties of Ti-xNi alloys fabricated by spark plasma sintering10.1016/j.heliyon.2023.e15887 ↗
31. Film breakdown and anodic dissolution during stress corrosion cracking of carbon steel in bioethanol10.1149/1.3269927 ↗
32. Advances in metals and alloys for joint replacement10.1016/j.pmatsci.2017.04.002 ↗
33. M.J.T. Adib-Yadzi, About a synthetic saliva for in vitro studies10.1016/S0039-9140(00)00618-4 ↗
34. Preparation of titanium oxide and hydroxyapatite on Ti-6Al-4V alloy surface and electrochemical behaviour in bio-simulated fluid solution10.1016/j.corsci.2013.11.059 ↗
35. Electrochemical impedance spectroscopy study of Ti–6Al–4V alloy in artificial saliva with fluoride and/or bovine albumin10.1016/j.dental.2005.01.009 ↗
36. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium10.1016/j.actbio.2005.09.004 ↗
37. Laboratory corrosion testing of medical implants
38. A novel Ti42.5Zr42.5Nb5Ta10 multi-principal element alloy with excellent properties for biomedical applications10.1016/j.intermet.2022.107731 ↗
39. High-strength β stabilized Ti-Nb-Fe-Cr alloys with large plasticity10.1016/j.msea.2018.07.031 ↗
40. Preferred orientation relationship of intra- and inter-granular precipitates in titanium alloys10.1016/S0921-5093(01)01829-9 ↗
41. Oda · Electrochem. Behav. Free-Mach. Titan. Alloy J. Dent. Res. · 2001 · 80
42. The effect of fluoride ions on the corrosion behavior of pure titanium in 0.05 M sulfuric acid10.1016/j.electacta.2014.05.055 ↗
43. Coupling between dissolution and passivation revisited - Kinetic parameters of anodic oxidation of titanium alloys in a fluoride-containing electrolyte10.1016/j.jelechem.2014.09.016 ↗
44. A kinetic model for the anodic dissolution of Ti in HF in the active and passive regions10.1149/2.0251509jes ↗
45. The corrosion behavior of Ti6Al4V fabricated by selective laser melting in the artificial saliva with different fluoride concentrations and pH values10.1016/j.corsci.2020.109097 ↗
46. Is niobium more corrosion-resistant than commercially pure titanium in fluoride-containing artificial saliva?10.1016/j.electacta.2017.03.015 ↗
47. An electrochemical impedance spectroscopy and polarization study of the role of crystallographic orientation on electrochemical behavior of niobium10.1016/j.electacta.2013.12.085 ↗
48. Corrosion behavior of new quaternary ZrNbTiAl alloys in simulated physiological solution using electrochemical techniques and surface analysis methods10.1016/j.electacta.2017.07.157 ↗
49. Effect of microstructure and temperature on electrochemical behavior of niobium in phosphate-buffered saline solutions10.1149/2.003302jes ↗
50. Corrosion behavior and surface film characterization of TaNbHfZrTi high entropy alloy in aggressive nitric acid medium10.1016/j.intermet.2017.06.002 ↗
51. An integrated approach to electrochemical impedance spectroscopy10.1016/j.electacta.2007.10.075 ↗
52. Changing the second phase distribution shape and improving the corrosion resistance of Mg-6.7Y-2.5Zn alloy by addition of trace Ta10.1016/j.corsci.2023.111341 ↗
53. Corrosion mechanisms of steel concrete moulds in contact with a demoulding agent studied by EIS and XPS10.1016/S0010-938X(03)00076-3 ↗
54. Dielectric properties of materials showing Constant-Phase-Element (CPE) impedance response10.1149/2.033306jes ↗
55. The analysis of electrode impedances complicated by the presence of a constant phase element10.1016/S0022-0728(84)80324-1 ↗
56. Passivation behavior and surface chemistry of 2507 super duplex stainless steel in artificial seawater: influence of dissolved oxygen and pH10.1016/j.corsci.2019.02.002 ↗
57. Influence of fluoride concentration and pH on corrosion behavior of titanium in artificial saliva10.1007/s10800-006-9283-z ↗
58. Determination of effective capacitance and film thickness from constant-phase-element parameters10.1016/j.electacta.2009.10.065 ↗
59. A new equation for predicting the dielectric constant of a mixture10.1111/j.1151-2916.1993.tb03985.x ↗
60. Corrosion and passivation of annealed Ti-20Zr-6.5Al-4V alloy10.1016/j.corsci.2015.08.038 ↗
61. Influence of titanium ion on mineral formation and properties of osteoid nodules in rat calvaria cultures10.1002/(SICI)1097-4636(199911)47:2<220::AID-JBM12>3.0.CO;2-9 ↗
62. Influences of formation potential on oxide film of TC4 in 0.5 M sulfuric acid10.1016/j.apsusc.2020.148888 ↗
63. Effects of Zr addition on the microstructural evolution, mechanical properties, and corrosion behavior of novel biomedical Ti-Zr-Mo-Mn alloys
64. The migration of metal and oxygen during anodic film formation10.1149/1.2423662 ↗
65. The effect of electrolyte anions incorporated into anodic oxide films on the experimental transport numbers of ions10.1016/j.electacta.2010.09.053 ↗
66. (TiZrNbTa)90Mo10 high-entropy alloy: electrochemical behavior and passive film characterization under exposure to Ringer's solution10.1016/j.corsci.2020.108513 ↗
67. Influences of structure and composition on growth of anodic oxide films on Ti-Zr alloys10.1016/S0013-4686(03)00383-9 ↗
68. Pitting corrosion on zirconium—a review10.5006/1.3579296 ↗
69. Evaluation of corrosion resistance of implant-use Ti-Zr binary alloys with a range of compositions10.1002/jbm.b.33811 ↗
70. Comparison of different methods for measuring the passive film thickness on metals10.1016/j.electacta.2015.12.173 ↗
71. Quantitative electron spectroscopy of surfaces: a standard data base for electron inelastic mean free paths in solids10.1002/sia.740010103 ↗
72. Tribocorrosion behaviors of a biodegradable Mg65Zn30Ca5 bulk metallic glass for potential biomedical implant applications10.1016/j.jallcom.2018.02.138 ↗
73. Contact and rubbing of flat surfaces10.1063/1.1721448 ↗
74. Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid10.1016/j.actbio.2016.07.008 ↗
75. Evaluation of the mechanical and wear properties of titanium produced by three different additive manufacturing methods for biomedical application10.1016/j.msea.2019.06.024 ↗