Evaluation of NDT-signals for use in the fracture mechanics safety analysis
Source abstract
Abstract
The defect size determination in components is a difficult question which has to be solved for safety analysis reasons. By using non-destructive techniques like UT inspection there remain restrictions related to the difference between UT-signal and real defect size. Extensive investigations of different types of components were made to generate basic data for the correlation UT-signal—real defect size. This paper describes a procedure for the transformation of UT-signals for embedded single defects into a defect size which could be used for the safety analysis by stress intensity procedures. The introduced corrective factor k for the equation AFS = k • EFBH (actual flaw size diameter, equivalent flat bottom hole) is k = 2.0, resp k = 1.7.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fatigue and fracture mechanics · Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Siemens AG, Power Generation Group (KWU), Mülheim/R., Germany
MPA Stuttgart, Germany
References (3)
Show source-provided references
1. Ewald J. · 1995 · 04 · 25
2. 10.1007/978-94-011-1048-8_810.1007/978-94-011-1048-8_8 ↗
3. 10.1080/09603409.1998.1168961810.1080/09603409.1998.11689618 ↗