journal article·2008-07

Cracking patterns and strength of CFT beams under different moment gradients

Waleed Shawkat, Waleed Fahmy, Amir Fam

Composite Structures· Volume 84· Issue 2
Publisher page

Abstract

Abstract Rectangular concrete-filled tubes (CFTs), fabricated using steel and pultruded glass–fiber reinforced polymer (GFRP) tubes were tested in three-point bending, at different shear span-to-depth ( a / d ) ratios of 1–5 to examine crack patterns, strength and failure modes. It was shown that the critical ( a / d ) ratio, at which moment capacity drops, is between 4 and 5 for CFTs with GFRP tubes and between 1 and 2 for CFTs with steel tubes. On the other hand, for steel tubes, ductility is drastically reduced at ( a / d ) ratios below 3. The crack pattern and size were highly dependent on the magnitude of slip between concrete and tube. A major full depth flexural crack was developed in all CFTs with GFRP tubes, even at a / d = 1, however, when internal steel rebar was added, major diagonal cracks were formed in addition to fine flexural cracks. In CFTs with steel tubes, fine flexural cracks were developed, except at a / d = 1 where fine diagonal cracks were predominant. A strut-and-tie model was developed to predict the strength of CFT beams and provided reasonable agreement with test results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Experimental studies on the ultimate moment of concrete filled square steel tubular beam-columns
2. Lu YQ, Kennedy DJL. The flexural behavior of concrete-filled hollow structural sections. Structural engineering report 178. Edmonton, AB: Department of Civil Engineering, University of Alberta, Alberta, Canada; 1992.
3. Kilpatrick AE, Rangan BV. Tests on high-strength composite concrete columns. Research report no. 1/97. Perth, Western Australia: School of Civil Engineering, Curtin University of Technology; 1997.
4. Karbhari VM. Structural characterization of fiber-reinforced composite short- and medium-span bridge systems. In: Proceedings of European Conference on Composite Materials (ECCM-8); June 1998. p. 35–42.
5. Large beam-column tests on concrete-filled composite tubes
6. Flexural behavior of concrete-filled fiber reinforced circular polymer tubes10.1061/(ASCE)1090-0268(2002)6:2(123) ↗
7. Flexural load testing of concrete-filled FRP tubes with longitudinal steel and FRP rebar10.1061/(ASCE)1090-0268(2006)10:2(161) ↗
8. Strength and ductility of hybrid FRP-concrete beam-columns10.1061/(ASCE)0733-9445(1999)125:10(1085) ↗
9. Composite t-beams using reduced scale rectangular FRP tubes and concrete slabs10.1061/(ASCE)1090-0268(2006)10:2(172) ↗
10. Rectangular filament-wound GFRP tubes filled with concrete under flexural and axial loading: experimental investigation10.1061/(ASCE)1090-0268(2005)9:1(25) ↗
11. Ahmad I, Zhu Z, Mirmiran A, Fam A. Shear strength prediction of deep CFFT beams. ACI special publication SP-230-61; 2005. p. 1085–102.
12. Cole B. Flexural and shear performances of reinforced concrete-filled fibre reinforced polymer tubes. M.Sc. thesis. Kingston, ON: Department of Civil Engineering, Queen’s University; 2005. p. 201.
13. Precast composite piles for the route 40 bridge in Virginia using concrete-filled FRP tubes10.15554/pcij.05012003.32.45 ↗
14. Fam A, Greene R, Rizkalla S. Field applications of concrete-filled FRP tubes for marine piles. Field application of FRP reinforcement: case studies. ACI special publication SP-215-9; 2003. p. 161–80.