Vibration isolation of LNG containment systems due to sloshing with glass fiber composite
Source abstract
Abstract
Abstract Since the stainless steel primary barriers of Cryogenic Containment System (CCS) for Liquefied Natural Gas (LNG) ship failed by impact loads due to LNG cavitation during operation, the stiffness and strength of the primary barrier was increased much to endure the impact pressure of LNG, which increased the transfer of impact load to foam insulation panels under the primary barrier. The increase of impact load to the foam insulation panels will induce crack propagation into the insulation foam panels due to the low toughness of insulation foams at cryogenic temperatures. In this work, an impact isolation system was developed using glass fiber composite mats to lower the impact load transmission into the foam insulation panels. An optimal design process for the vibration isolation system was conducted by a numerical method. For reliability of the impact isolation system, cryogenic fatigue tests of the glass fiber composite mats were performed. Also, an impact test equipment with low impact duration was developed to simulate the efficiency of the impact isolation system.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fluid Dynamics Simulations and Interactions · Spacecraft and Cryogenic Technologies · Methane Hydrates and Related Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Leakage characteristics of the glass fabric composite barriers of LNG ships10.1016/j.compstruct.2008.03.021 ↗
2. Zalar M, Malenica S, Mravak Z, Moirod N. Some aspects of direct calculation methods for the assessment of LNG tank structure under sloshing impact. In: Int conf liquefied natural gas, Barcelona, Spain; 2007.
3. Pressure resistance of the corrugated stainless steel membranes of LNG carriers
4. Rudman M, Cleary PW. Modeling sloshing in LNG tanks. In: International conference on CFD in the minerals and process industries, CSIRO, Melbourne, Australia; 9–11 December, 2009.
5. Collapse of an initially spherical cavity in the neighborhood of a solid boundary10.1017/S0022112071001058 ↗
6. Brennen · 1995
7. Franc · 2004
8. Barron · 1985
9. Tusiani · 2007
10. Peters · 1998
11. ASTM D 165-07. Standard test method for measuring compressive properties of thermal insulations. Annual Book of ASTM Standards Online, 04:06.
12. Hasebrink · 1978
13. Zukas · 1982