Eddy-current array-probe technique for imaging near-surface and deep-lying delaminations in multidirectional carbon fiber composites
Source abstract
Abstract
Abstract An eddy-current array-probe method was proposed to visualize delamination occurring within multidirectional carbon fiber-reinforced plastics. First, samples with a near-surface delamination were scanned by a coil array probe comprising a single driver coil and multiple pickup coils, and the detectability of the delamination was evaluated by the signal-to-noise ratio. An appropriate selection of the image phase and the distance between the driver and pickup coils enabled detection of the delamination suppressing the signal variation in the non-defective region. Furthermore, the experimental results suggested that the distance between the driver coil and the most sensitive pickup coil correlated with the delamination size . Second, the array-probe technique was used to detect a delamination located at various depths. The detectability of the delamination was found to be strongly affected by the rotation angle of the array probe. The optimum probe rotation angle depended on the depth of the delamination, indicating that a delamination occurring in deeper regions can be visualized by setting an appropriate probe rotation angle.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Delamination monitoring of laminated composites subjected to low-velocity impact using small-diameter FBG sensors10.1016/j.compositesa.2004.12.005 ↗
2. Delamination prediction in composite laminates under low-velocity impact10.1016/j.compstruct.2015.05.037 ↗
3. Predicting delamination of composite laminates using an imaging approach
4. Transient thermography in the assessment of defects of aircraft composites10.1016/S0963-8695(03)00052-5 ↗
5. Induction welding of thermoplastic composites—an overview
6. Experimental study into compression after impact strength of laminates with conventional and nonconventional ply orientations
7. Detection and localization of delaminations in thin carbon fiber reinforced composites with the ultrasonic polar scan10.1007/s10921-014-0249-5 ↗
8. In situ detection of damage in CFRP laminates by electrical resistance measurements10.1016/S0266-3538(98)00132-8 ↗
9. Matrix crack detection of CFRP using electrical resistance change with integrated surface probes10.1016/j.compscitech.2005.11.029 ↗
10. Review on quality assurance along the CFRP value chain – non-destructive testing of fabrics, preforms and CFRP by HF radio wave techniques
11. Novel electromagnetic modeling approach of carbon fiber-reinforced polymer laminate for calculation of eddy currents and eddy current testing signals10.1177/0021998314521475 ↗
12. Application of low frequency ECT method in noncontact detection and visualization of CFRP material
13. Contactless high-speed eddy current inspection of unidirectional carbon fiber reinforced polymer
14. Non-destructive characterisation of carbon-fibre-reinforced plastics by means of eddy-currents10.1016/S0266-3538(00)00164-0 ↗
15. Detection of in-plane and out-of-plane fiber waviness in unidirectional carbon fiber reinforced composites using eddy current testing
16. Detection of in-plane fiber waviness in cross-ply CFRP laminates using layer selectable eddy current method
17. Visualization and size estimation of fiber waviness in multidirectional CFRP laminates using eddy current imaging
18. Automated detection of yarn orientation in 3D-draped carbon fiber fabrics and preforms from eddy current data
19. Non-contact visualization of fiber waviness distribution in carbon fiber composites using eddy current testing10.1080/09243046.2017.1344917 ↗
20. Characterisation of carbon fibre-reinforced polymer composites through radon-transform analysis of complex eddy-current data
21. Development and application of eddy current sensor arrays for process integrated inspection of carbon fibre preforms10.3390/s18010004 ↗
22. A simulative and experimental approach toward eddy current nondestructive evaluation of manufacturing flaws and operational damage in CFRP composites10.1115/1.4044722 ↗
23. Evaluation of detectability of differential type probe using directional eddy current for fibre waviness in CFRP
24. Interlaminar contact resistivity and its influence on eddy currents in carbon fiber reinforced polymer laminates10.1016/j.ndteint.2017.12.003 ↗
25. Detection of delamination in laminated CFRP composites using eddy current testing: Simulation and experimental study10.3233/JAE-170136 ↗
26. Enhancement of sensitivity to delamination in eddy current testing of carbon fiber composites by varying probe geometry
27. Eddy current testing for estimation of anisotropic electrical conductivity of multidirectional carbon fiber reinforced plastic laminates10.1016/j.compositesa.2021.106274 ↗
28. Non-contact strain monitoring of carbon fiber composites using spatial frequency domain eddy current imaging data10.1016/j.measurement.2020.108589 ↗
29. A fast forward simulation scheme for eddy current testing of crack in a structure of carbon fiber reinforced polymer laminate10.1109/ACCESS.2019.2947365 ↗
30. Through-thickness electric conductivity of toughened carbon-fibre reinforced polymer laminates with resin-rich layers10.1016/j.compscitech.2015.11.018 ↗
31. Role of interlaminar interface on bulk conductivity and electrical anisotropy of CFRP laminates measured by eddy current method10.1016/j.ndteint.2014.07.001 ↗