Dynamic performance characteristics of an innovative Hybrid Composite Floor Plate System under human-induced loads
Source abstract
Abstract
This study explored the dynamic performance of an innovative Hybrid Composite Floor Plate System (HCFPS), composed of Polyurethane (PU) core, outer layers of Glass–fibre Reinforced Cement (GRC) and steel laminates at tensile regions, using experimental testing and Finite Element (FE) modelling. Experimental testing included heel impact and walking tests for 3200 mm span HCFPS panels. FE models of the HCFPS were developed using the FE program ABAQUS and validated with experimental results. HCFPS is a light-weight high frequency floor system with excellent damping ratio of 5% (bare floor) due to the central PU core. Parametric studies were conducted using the validated FE models to investigate the dynamic response of the HCFPS and to identify characteristics that influence acceleration response under human induced vibration in service. This vibration performance was compared with recommended acceptable perceptibility limits. The findings of this study show that HCFPS can be used in residential and office buildings as a light-weight floor system, which does not exceed the perceptible thresholds due to human induced vibrations.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Engineering and Vibration Analysis · Structural Health Monitoring Techniques · Railway Engineering and Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Ferreira JG, Branco FA. GRC mechanical properties for structural applications. In: Institute Superior Techno. Portugal; 2004. p. 1049–001.
2. Performance characteristics of compound curved sandwich shell structures
3. Braun D, Kennedy SJ, Kennedy DJL, Allen DE. Sandwich plate system risers for stadia. In: SSRC 2002 annual stability conference. Seattle, Washington, USA; 2002.
4. Flexural performance of sandwich panels comprising polyurethane core and GFRP skins and ribs of various configurations10.1016/j.compstruct.2010.05.004 ↗
5. Experimental investigation of large-scale cladding sandwich panels under out-of-plane transverse loading for building applications10.1061/(ASCE)CC.1943-5614.0000176 ↗
6. Methods for polyurethane and polyurethane composites, recycling and recovery: a review10.1016/j.reactfunctpolym.2007.05.004 ↗
7. GRC In Action. International glassfibre reinforced concrete association [Internet]; 2003. .
8. Flexural performance of an innovative hybrid composite floor plate system comprising glass–fibre reinforced cement, polyurethane and steel laminate10.1016/j.compstruct.2012.06.019 ↗
9. Development of an Innovative hybrid-composite floor system
10. Abeysingh CM, Thambiratnam DP, Perera NJ. Investigation of hybridized polyurethane, glass fibre reinforced cement and steel laminate in structural floor plate systems. In: The first international postgraduate conference on engineering, designing and developing the built environment for sustainable wellbeing. Queensland University of, Technology; 2011. p. 249–53.
11. Abeysingh CM, Thambiratnam DP, Perera NJ. Innovative hybrid composite floor plate system. In: Haddad YM, editor. AES-ATEMA’2012 tenth international conference. McGill University, Montreal, Canada; 2012.
12. ISO 10137, Bases for design of structures-serviceability of buildings against vibrations. International Standardisation Organisation: Geneva Switzerland; 2007.
13. BS 6472-1:2008, Guide to evaluation of human exposure to vibration in buildings. Vibration sources other than blasting. British Standards: BSI, UK; 2008.
14. Smith · 2007
15. Murray · 2003
16. Sandun De Silva S. Vibration characteristics of steel-deck composite floors under human exitation. In: School of urban development, faculty of build environment and engineering. QUT Brisbane; 2007.
17. Jetann C. Development of the response coefficient-root function method for the transient vibration serviceability design of flat concrete floors. In: School of urban development, faculty of build environment and engineering. QUT Brisbane; 2010.
18. Ellis BR. Dynamic monitoring. In: Monitoring and assessment of structures. New York; 2001a. p. 8–31.10.4324/9780203478011.ch2 ↗
19. Floor vibrations: tips for designers of office buildings
20. Deterministic and probabilistic floor response spectra10.1016/S0267-7261(03)00064-2 ↗
21. Dynamic tests on a steel-joist concrete-slab floor10.1139/l80-029 ↗
22. Dynamic characteristics of steel-deck composite floors under human-induced loads10.1016/j.compstruc.2009.04.005 ↗
23. Vibration design and testing of a long-span lightweight floor
24. Wyatt · 1989
25. Damping properties and transmission loss of polyurethane. (I. effect of soft and hard segment compositions)10.1002/(SICI)1097-4628(20000131)75:5<604::AID-APP2>3.0.CO;2-# ↗
26. Abaqus Analysis User’s Manual, Version 6.9-1: ABAQUS Inc.
27. Sun EQ. Shear locking and hourglassing in msc nastran, abaqus, and ansys. MSC Software; 2006.
28. Design to prevent floor vibrations10.62913/engj.v12i3.248 ↗
29. Clough · 1993
30. Evaluation of floor vibration in a biotechnology laboratory caused by human walking10.1061/(ASCE)0887-3828(2008)22:3(122) ↗
31. Vibration serviceability of footbridges under human-induced excitation: a literature review10.1016/j.jsv.2004.01.019 ↗
32. Guidelines on the design for floor vibration due to human actions part II: Floor vibration due to walking loadshong kong: structural engineering branch, architectural services department (ArchSD); 2009.
33. AS/NZS 1170.1, Structural design actions, Part 1: Permanent, imposed and other actions. Standards Australia: Sydney, NSW, Australia; 2002.
34. Elnimeiri M, Iyenga H. Composite floor vibrations: predicted and measured in steel structures. San Francisco, CA, USA: American Society of Civil Engineers; 1989.
35. Shear properties of polyurethane foams with different densities
36. A holistic approach to static design of sandwich beams with foam cores10.1177/1099636208095741 ↗
37. Effect of foam density on the properties of water blown rigid polyurethane foam10.1002/app.27712 ↗
38. On the response of long span floors to walking loads generated by individuals and crowds
39. Serviceability evaluation of floor vibration induced by walking loads