Mechanical behaviors of Ti/CFRP/Ti laminates with different surface treatments of titanium sheets
Source abstract
Abstract
The Metal Composite Interface (MCI) properties affect not only the integrity of Fiber Metal Laminates (FMLs), but also the deformation/failure modes of FMLs. In this paper, the influence of MCI on the mechanical behaviors of Ti/CFRP/Ti laminates were experimentally investigated through indentation tests and low velocity impact tests. Three different surface treatments of titanium sheets were prepared to obtain the different MCI strength based on annealing, sandblasting, and anodizing. The treated surfaces of titanium sheets were analyzed using Field Emission Scanning Electron Microscope (FE-SEM) and Energy Dispersive X-ray Spectrom (EDX). The MCI strength was characterized by apparent shear strength between titanium sheet and epoxy, which was measured through single lap shear test. The deformation/failure modes and energy absorption capacity of FMLs were analyzed. It was demonstrated that the MCI strength was greatly enhanced when the metal surfaces were sandblasted and anodized. The results showed that the improved MCI helped to maintain the integrity of FMLs under quasi-static and dynamic loadings. However, FMLs with higher MCI strength seemed to have weak resistance to damage and low energy absorption capacity.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical Behavior of Composites · Metal and Thin Film Mechanics · Mechanical stress and fatigue analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Vlot · 2001
2. A review on the development and properties of continuous fiber/epoxy/aluminum hybrid composites for aircraft structures10.1590/S1516-14392006000300002 ↗
3. The mechanical behavior of GLARE laminates for aircraft structures10.1007/s11837-005-0067-4 ↗
4. A review: fibre metal laminates, background, bonding types and applied test methods10.1016/j.matdes.2011.03.011 ↗
5. Low velocity impact response of fibre-metal laminates–a review10.1016/j.compstruct.2013.08.003 ↗
6. Preliminary evaluation of hybrid titanium composite laminates10.1080/00218469508014392 ↗
7. An investigation into the fatigue of a hybrid titanium composite laminate10.1520/CTR10494J ↗
8. Structure–properties relations in titanium-based thermoplastic fiber–metal laminates10.1002/pc.20189 ↗
9. Fatigue damage in titanium-graphite hybrid laminates10.1016/S0266-3538(02)00027-1 ↗
10. The prediction of tensile failure in titanium-based thermoplastic fibre–metal laminates10.1016/j.compscitech.2005.11.031 ↗
11. Low-velocity impact response characterization of a hybrid titanium composite laminate10.1115/1.2400272 ↗
12. Damage characterization of titanium/GFRP hybrid laminates subjected to low-velocity impact10.1016/j.compositesa.2011.03.005 ↗
13. Optimization of surface treatment and adhesive selection for bond durability in Ti-15-3 laminates10.1080/00218469908014844 ↗
14. Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina blasted/acid etched Ti-6Al-4V implant surfaces10.1002/jbm.a.32097 ↗
15. Surface modification of Ti dental implants by grit-blasting and micro-arc oxidation10.1080/10426911003747915 ↗
16. Oxidation of Ti–6Al–4V alloy10.1016/j.jallcom.2008.04.024 ↗
17. Surface morphology of a laser surface nitrided and etched Ti–6Al–4V alloy10.1016/j.surfcoat.2004.07.076 ↗
18. St. Polyimide–silica hybrids containing novel phenylethynyl imide silanes as coupling agents for surface-treated titanium alloy10.1016/S0143-7496(00)00017-8 ↗
19. Plasma etching of Ti in fluorine containing feeds10.1063/1.350679 ↗
20. Titanium oxide nanotube arrays prepared by anodic oxidation10.1557/JMR.2001.0457 ↗
21. TiO2 nanotube arrays of 1000μm length by anodization of titanium foil: phenol red diffusion10.1021/jp075258r ↗
22. Fabrication of titanium oxide nanotube arrays by anodic oxidation10.1016/j.ssc.2005.02.028 ↗
23. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation10.1016/j.biomaterials.2003.09.048 ↗
24. Surface modification of a Ti–6Al–4V alloy by thermal oxidation10.1016/j.surfcoat.2004.05.018 ↗
25. Thermal oxidation of Ti6Al4V alloy: microstructural and electrochemical characterization10.1016/j.matchemphys.2009.09.007 ↗
26. Organo-metallic complex characterization formed when liquid epoxy-diamine mixtures are applied onto metallic substrates10.1016/S0032-3861(01)00034-9 ↗
27. Comparative determination of TiO2 surface free energies for adhesive bonding application10.1016/j.ijadhadh.2011.08.003 ↗
28. Surface modifications of Ti alloy with tunable hierarchical structures and chemistry for improved metal–polymer interface used in deepwater composite riser10.1016/j.apsusc.2014.12.081 ↗
29. Surface microstructures and epoxy bonded shear strength of Ti6Al4V alloy anodized at various temperatures10.1016/j.compscitech.2013.04.007 ↗
30. Effects of primer and annealing treatments on the shear strength between anodized Ti6Al4V and epoxy10.1016/j.ijadhadh.2014.10.004 ↗
31. Interfacial chemistry and adhesion between titanium dioxide nanotube layers and titanium substrates10.1021/jp111651d ↗
32. Impact damage resistance of various fibre metal laminates
33. Impact loading of plates and shells by free-flying projectiles: a review10.1016/0734-743X(95)00023-4 ↗
34. A similitude approach towards the understanding of low velocity impact characteristics of bi-layered hybrid composite structures10.1016/j.compstruct.2015.04.055 ↗
35. Debonding and impact damage in stainless steel fibre metal laminates prior to metal fracture10.1016/j.compstruct.2014.09.056 ↗