journal article·2000-01

Effect of trigger geometry on energy absorption in composite profiles

M.A Jiménez, A Miravete, E Larrodé, D Revuelta

Composite Structures· Volume 48· Issue 1-3
Publisher page

Abstract

This paper presents an experimental study on the energy absorption capability of two different composite profiles; both are realised in glass-polyester pultrusion. One of the profiles is a unidirectional box section, whilst the other, an I section, consists of alternating layers of mat and fabric. For each one of the two profiles, six different trigger geometries are analysed. The results show that the I profile is a good candidate for being considered for energy absorption applications. It is also concluded that when studying a trigger geometry, slight modifications (as the bevel angle of a bevel trigger) can result in important variations of the results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Analysis of Composite Materials · Mechanical Behavior of Composites · Cellular and Composite Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (7)

Show source-provided references
1. Hull D. Axial crushing of fiber reinforced composite tubes. In: Jones N, Wierzbicki T, editors. Structural Crashworthiness. Boston: Butterworth, 1983:118–35
2. Energy Absorption in composite tubes10.1177/002199838201600606 ↗
3. Larrodé E, Jiménez MA, Baselga S. Absorción de energı́a en vehı́culos mediante materiales compuestos de matriz orgánica. Actas del I Congreso Nacional de Materiales Compuestos- Sevilla 1995;233–38
4. The crush behaviour of galss fiber reinforced plastic sections10.1016/0266-3538(86)90032-1 ↗
5. Gupta NK et al. An analysis of axial crushing of composites tubes. J Composite Mater 1997;31(13):1262–8610.1177/002199839703101301 ↗
6. Energy absorption of composite materials10.1177/002199838301700307 ↗