On the response of thin-walled CFRP composite tubular components subjected to static and dynamic axial compressive loading: experimental
Source abstract
Abstract
Abstract In this work the crushing response and crashworthiness characteristics of thin-wall square FRP (fibre reinforced plastic) tubes that were impact tested at high compressive strain rate are compared to the response of the same tubes in static axial compressive loading. The material combination of the tested specimens was carbon fibres in the form of reinforcing woven fabric in epoxy resin, and the tested tubes were constructed trying three different laminate stacking sequences and fibre volume contents on approximately the same square cross-section. Comparison of the static and dynamic crushing characteristics is made by examining the collapse modes, the shape of the load–displacement curves, the peak and average compressive load and the absorbed amount of crushing energy in both loading cases. In addition, the influence of the tube geometry (axial length, aspect ratio and wall thickness), the laminate material properties-such as the fibre volume content and stacking sequence-and the compressive strain rate on the compressive response, the collapse modes, the size of the peak load and the energy absorbing capability of the thin-wall tubes is extensively analysed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cellular and Composite Structures · Mechanical Behavior of Composites · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Review: Crashworthy capability of composite material structures10.1016/S0263-8223(97)80005-0 ↗
2. Crash energy management in composite automotive structures10.1016/0734-743X(88)90024-3 ↗
3. A unified approach to progressive crushing of fibre-reinforced tubes10.1016/0266-3538(91)90031-J ↗
4. Crushing characteristics of continuous fibre-reinforced composite tubes10.1177/002199839202600103 ↗
5. Fairfull · 1988 · 255
6. Crashworthy behaviour of thin-walled tubes of fibreglass composite material subjected to axial loading10.1177/002199839002400104 ↗
7. Mamalis A, Manolakos D, Viegelahn. G. Deformation characteristics of crashworthy components. In: Fortschr.-Ber. VDI Reihe 18, Nr. 62, Düsseldorf: VDI-Verlag; 1989
8. On the axial crumpling of fibre-reinforced composite thin-walled conical shells
9. Microscopic failure of thin-walled fibre-reinforced composite frusta under static axial collapse
10. Collapse of thin-wall composite sections subjected to high speed axial loading
11. Analysis of failure mechanisms observed in axial collapse of thin-walled circular fibreglass composite tubes10.1016/0263-8231(95)00042-9 ↗
12. Axial collapse of thin-walled fibreglass composite tubular components at elevated strain rates10.1016/0961-9526(94)90107-4 ↗
13. The static and dynamic axial crumbling of thin-walled fibreglass composite square tubes10.1016/S1359-8368(96)00066-2 ↗
14. Mamalis · 1998
15. On the compression of hybrid sandwich composite panels reinforced with internal tube inserts: experimental10.1016/S0263-8223(02)00003-X ↗
16. Crashworthy characteristics of axially statically compressed thin-walled square CFRP composite tubes: experimental10.1016/S0263-8223(03)00183-1 ↗
17. Energy absorption of composite materials10.1177/002199838301700307 ↗
18. The effects of crushing speed on the energy-absorption capability of composite tubes10.1177/002199839102501004 ↗
19. Impact energy absorption of continuous fibre composite tubes10.1115/1.3225937 ↗