journal article·2015-05

Mechanical behavior of concrete-filled square steel tube with FRP-confined concrete core subjected to axial compression

Peng Feng, Shi Cheng, Yu Bai, Lieping Ye

Publisher page

Abstract

Abstract A novel column consisting of steel, concrete and fiber-reinforced polymer (FRP) is presented and assessed through experimental study. The sectional form of steel–concrete–FRP–concrete (SCFC) columns has a square steel tube as the outer layer and a circular filament-wound FRP tube as the inner layer, and concrete is filled between these two layers and within the FRP tube. Thus the column can be regarded as a concrete-filled square steel tube (CFST) with a FRP-confined concrete core (FCCC). In comparison to existing composite column sections, several advantages are achieved such as ease of connection to beams, the stronger confinement of core concrete, ductile response, and residual load capacity. 18 SCFC stub columns are tested with different concrete strengths, FRP tube thickness and steel tube thickness in comparison to four traditional composite columns. The distinctive behaviors of SCFC columns, including significant post-yield stiffness, ductile failure, and stable residual bearing capacity are found. Test results show that the strengths of concrete, FRP, and steel are effectively utilized at different stages, including the initial linear stage, the secondary linear stage (hardening stage), and the post-peak stage. The influences of key design parameters on the mechanical characteristics of initial compressive stiffness, peak strain, residual load-bearing capacity, and ductility are also clarified.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Large-span woven web structure made of fiber-reinforced polymer10.1061/(ASCE)1090-0268(2007)11:2(110) ↗
2. Capacity of nonlinear large deformation for trusses assembled by brittle FRP composites10.1016/j.compstruct.2012.05.016 ↗
3. Behavior of centrally loaded concrete-filled steel-tube short columns10.1061/(ASCE)0733-9445(2004)130:2(180) ↗
4. Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns10.1016/j.jcsr.2005.11.002 ↗
5. Experimental investigation of thin-walled complex section concrete-filled steel stub columns10.1016/j.tws.2010.05.001 ↗
6. Axial behavior of concrete-filled carbon fiber-reinforced polymer composite columns10.1002/tal.585 ↗
7. Effect of load eccentricity on the stress-strain relationship of FRP-confined concrete columns10.1016/j.compstruct.2012.11.023 ↗
8. Behavior of concrete columns confined with fiber reinforced polymer tubes
9. A new concrete-filled hollow FRP composite column10.1016/1359-8368(95)00019-4 ↗
10. Design-oriented stress-strain model for FRP-confined concrete10.1016/S0950-0618(03)00045-X ↗
11. Circular concrete-filled double skin tubular short columns with external stainless steel tubes under axial compression10.1016/j.tws.2013.08.017 ↗
12. Test and analysis of axial compressive behavior of short composite-sectioned high strength concrete filled steel tubular columns
13. Teng JG, Yu T, Wong YL. Behavior of hybrid FRP–concrete–steel double-skin tubular columns. In: Proceedings, second international conference on FRP composites in civil engineering, Adelaide, Australia, 8–10 December 2004. p. 811–8.10.1201/9780203970850.ch91 ↗
14. Concrete-filled steel tubes subjected to axial compression and lateral cyclic loads10.1061/(ASCE)0733-9445(2004)130:4(631) ↗
15. Behaviour of concrete-filled steel tubular stub columns subjected to axially local compression10.1016/j.jcsr.2007.10.002 ↗
16. Behavior and strength of circular concrete-filled tube columns10.1016/S0143-974X(02)00005-6 ↗
17. Axial capacity of circular concrete-filled tube columns10.1016/j.jcsr.2003.10.001 ↗
18. The practice of concrete filled steel tube piers to bridges: a review10.4028/www.scientific.net/AMM.405-408.1602 ↗
19. A study on the dynamic ultimate capacity of CFST arch bridges
20. Behavior of hybrid double skin concrete filled circular steel tube columns10.12989/scs.2013.14.2.191 ↗
21. Behavior of FRP-confined concrete in annular section columns10.1016/j.compositesb.2007.04.001 ↗
22. Shake table response and analysis of a concrete-filled FRP tube bridge column10.1016/j.compstruct.2011.12.018 ↗
23. Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes
24. Analytical models for concrete confined with FRP tubes10.1061/(ASCE)1090-0268(2003)7:1(31) ↗
25. Behavior of concrete columns confined by fiber composites10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
26. Performance of externally FRP reinforced columns for changes in angle and thickness of the wrap and concrete strength10.1016/j.compstruct.2005.02.019 ↗
27. Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes
28. Compressive strength of reinforced concrete column confined by composite material10.1016/j.compstruct.2003.11.001 ↗
29. Behavior of hybrid FRP–concrete–steel double-skin tubular columns with a square outer tube and a circular inner tube subjected to axial compression10.1061/(ASCE)CC.1943-5614.0000331 ↗
30. Comparative study of models on confinement of concrete cylinders with fiber reinforced polymer composites10.1061/(ASCE)1090-0268(2003)7:3(219) ↗
31. Design-oriented stress-strain model for FRP-confined concrete in rectangular columns10.1177/0731684403035429 ↗
32. Hybrid FRP–concrete–steel tubular columns: concept and behavior10.1016/j.conbuildmat.2006.06.017 ↗
33. A review on FRP composites applications and durability concerns in the construction sector10.1177/0731684413492868 ↗
34. Testing and modelling of a novel FRP-encased steel–concrete composite column10.1016/j.compstruct.2010.11.017 ↗
35. Strengthening of steel members in compression by mortar-filled FRP tubes10.1016/j.tws.2012.11.001 ↗
36. Experimental study on buckling resistance technique of steel members strengthened using FRP10.1142/S0219455412004604 ↗
37. Effects of corrosive environments on properties of pultruded GFRP plates10.1016/j.compositesb.2014.08.021 ↗
38. GB 50010-2010. National Standard of the People’s Republic of China. Code for design of concrete structures. Beijing, China: China Architecture and Building Press; 2010 [in Chinese].
39. JGJ 3-2011. Technical specification for concrete structures of tall building. Beijing, China: China Architecture and Building Press; 2011 [in Chinese].
40. ASTM D 2290-00. Standard test method for apparent hoop tensile strength of plastic or reinforced plastic pipe by split disk method.
41. BS 18. Tensile testing of metals (including aerospace materials). British Standards Institution, London, UK; 1987.
42. Confined concrete-filled tubular columns10.1061/(ASCE)0733-9445(2005)131:3(488) ↗
43. CECS 188. Technical specification for steel tube-reinforced concrete column structure. Beijing, China: China Planning Press; 2005 [in Chinese].
44. Park R. Ductility evaluation from laboratory and analytical testing. In: Proceedings of ninth world conference on earthquake engineering, Tokyo-Kyoto, Japan; 1988. p. 605–16.