Characterization of temperature-induced stiffness changes in a C-PMR15 composite material by means of laser generated and detected ultrasound

S. Guilbaud, B. Audoin

Composites Science and Technology· Volume 61· Issue 3
Publisher page

Abstract

Nine stiffness coefficients of a polymer-matrix composite material have been measured by a contactless process method which consists in the focusing of a pulsed laser beam on one side of a sample to generate acoustic waves through the material. A laser interferometric probe is used on the other side to detect the acoustic wavefronts. These devices are associated with a specific oven allowing the transmission of the optical beams. The nine coefficients are measured for several temperatures increased by steps up to the matrix glass-transition temperature. The changes of coefficients with temperature show anisotropic decreases of the stiffness properties. It is worth noting the changes of the shear coefficients that are associated with the decrease of the matrix properties.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Thermography and Photoacoustic Techniques · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (9)

Show source-provided references
1. Acoustic waves generated by a line source in a viscoelastic medium10.1063/1.120889 ↗
2. Transient elastic waves in a transversely isotropic plate10.1115/1.2788870 ↗
3. Measurement of the stiffness coefficients of a viscoelastic composite material with laser generated and detected ultrasound10.1121/1.426827 ↗
4. Grossman A, Holschneider M, Kronland-Martinet R, Morlet J. Detection of abrupt changes in sound signals with the help of wavelet transforms. In: Inverse problems. Academic Press, 1987. p. 289–306.
5. Audoin B, Bescond C, Guibaud S. Evaluation à température élevée des coefficients d'élasticité d'un matériau composite au moyen d'ultrasons générés par laser. In: Baptiste D, Vautrin A, editors. Proceedings of Journées Nationales sur les Composites 10, Paris, 29–31 October. AMAC, 1996. p. 1187–96.
6. Numerical method to recover the elastic constants from ultrasound group velocities10.1016/0041-624X(95)00024-W ↗
7. Audoin B, Bescond C, Qian M. Measurement of the stiffness tensor of orthotropic materials from line source point receiver laser ultrasonicmethod. In: Green E, editor. Proceedings of 8th Int. Symp. Nond. Charac. Mat., Boulder, CO, 1997. New York: Plenum Press, 1998.
8. Royer D, Dieulesaint E. Optical detection of sub-Angstrom transient mechanical displacement. IEEE Ultrason. Symp. Proc., 1986, 527–30.10.1109/ULTSYM.1986.198793 ↗
9. Marais C, Deloge N. Caractérisation mécanique de la résine polyimide PMR15 elaborée à différentes cuissons (ONERA no. 7/3718 MY), 1993.