Effect of the crack length on the piezoelectric damage monitoring of glass fiber epoxy composite DCB specimens
Source abstract
Abstract
Abstract A new nondestructive method using the piezoelectric characteristics of polymer matrix was suggested for the damage monitoring of glass fiber polymer composites, and the feasibility of the use of the method was proven through basic experiments. Heretofore, most studies have focused on basic material properties such as the piezoelectric properties of unidirectional glass fiber epoxy composites with respect to the fiber orientation or the loading speed. In this study, the effect of the crack length on the piezoelectric damage monitoring of glass fiber polymer composites was experimentally investigated. Dynamic tests of mode I were performed using double-cantilever-beam (DCB) specimens, and the relationship between the crack length and the electric-charge signals measured from the electrodes on the DCB specimens was analyzed. The experiment results showed that the magnitude of the electric-charge signals increased very slowly as the crack tip approached the electrodes, rose sharply when the crack tip was passing through the electrodes, and then decreased fast and maintained relatively very low values when the crack tip had completely passed through the electrodes. The investigation of the mechanical behaviors via finite-element analyses during the dynamic tests revealed that the tendency of electric-charge signals is quite similar to that of the strain changes in glass fiber epoxy composites near electrodes. Based on the results of the experiments and finite-element analyses conducted in this study, it was concluded that piezoelectric damage monitoring can detect crack propagation.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Smart Materials for Construction · Ultrasonics and Acoustic Wave Propagation · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. A review of nondestructive testing of composite materials10.1016/0308-9126(82)90001-3 ↗
2. Detection of damages in composite laminates with embedded optical fibers
3. Real-time monitoring of fatigue damage and dynamic strain in carbon fiber polymermatrix composite by electrical resistance measurement10.1088/0964-1726/6/4/017 ↗
4. Application of electric potential method to smart composite structures for detecting delamination
5. Damage detection in CFRP by electrical conductivity mapping10.1016/S0266-3538(00)00178-0 ↗
6. Self-sensing of damage and strain in carbon fiber polymer-matrix structural composites by electrical resistance measurement10.1177/096739110301100701 ↗
7. Experimental and finite element study of the electrical potential technique for damage detection in CFRP laminates10.1088/0964-1726/14/1/014 ↗
8. Comparative evaluation of the electrical configurations for the two-dimensional electric potential method of damage monitoring in carbon fiber polymer–matrix composite10.1088/0964-1726/15/5/023 ↗
9. Detection of impact damage in CFRP laminates by means of electrical potential techniques10.1016/j.compscitech.2006.07.033 ↗
10. Piezoresistivity of unidirectional carbon/epoxy composites for multiaxial loading10.1016/j.compscitech.2009.03.023 ↗
11. Feasibility study of the damage monitoring for composite materials by the piezoelectric method10.3795/KSME-A.2008.32.11.918 ↗
12. Effect of strain rate on piezoelectric characteristics of unidirectional glass fiber epoxy composites10.1177/0021998310376112 ↗
13. Electromechanical characteristics of unidirectional glass fiber epoxy composites10.1002/pc.21076 ↗
14. ASTM, D 5528. Standard test method for mode I interlaminar fracture toughness of unidirectional fiber-reinforcement polymer matrix, composites; 2007.
15. ASTM, D 6115. Standard test method for mode I fatigue delamination growth onset of unidirectional fiber-reinforcement polymer matrix, composites; 2004.
16. Piezoelectric monitoring of the reliability of adhesive joints10.1163/156856103321645158 ↗
17. Diagnosis criterion for damage monitoring of adhesive joints by the piezoelectric method10.1163/156856105774382462 ↗
18. Prediction of the crack length and crack growth rate of adhesive joints10.1163/156856105774382453 ↗