Mechanical properties and modelling of a hydrophilic composite used as a biomaterial
Source abstract
Abstract
Artifcial ligaments were fabricated by reinforcing a hydrophilic thermoplastic polyurethane matrix with poly-ethyleneterephtalate (PET) fibres, using the flament winding technology. The specimens were then tested in simple tension to measure the mechanical properties of the artificial ligaments. In order to investigate on the effect of technological parameters, three types of windings were manufactured, each type being identified by the winding angle and the fibre volume fraction that were used. Moreover, a certain amount of the PET ?bres was plasma-treated before winding, so composite ligaments reinforced with plasma-treated fibres were obtained. All of the artificial ligaments displayed the typical J-shaped stressstrain curve of natural ligaments, the plasma-treated ones mainly exhibiting a smaller toe region. A mathematical model is proposed to predict the mechanical behaviour of the artificial ligaments. The model is able to reproduce the behaviour of the artificial ligaments, especially the ones reinforced with plasma-treated fibres, and can be further used to simulate the behaviour of artificial ligaments subject to a more physiological deformation history, such as the combination of tension and torsion.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Tribology and Wear Analysis · Advanced Sensor and Energy Harvesting Materials · Mechanical Behavior of Composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Continuous fibre reinforced polymers as connective tissue replacement10.1016/j.compscitech.2003.09.008 ↗
2. Classification of prosthetic ligament failures, part II
3. Patient satisfaction needs as related to knee stability and objective findings after ACL reconstruction using the LARS artificial ligament10.1016/S0968-0160(00)00039-9 ↗
4. Correlation between patients’ satisfaction and objective measurement of knee stability after ACL reconstruction using a patellar tendon autograft10.1016/S0968-0160(00)00076-4 ↗
5. 10–16 year results of Leeds–Keio anterior cruciate ligament reconstruction10.1016/S0968-0160(03)00076-0 ↗
6. Analysis of retrieved polymer fiber based replacements for the ACL10.1016/S0142-9612(00)00114-9 ↗
7. Physical and chemical decay of prosthetic ACL after in vivo implantation10.1016/0267-6605(94)90006-X ↗
8. Mechanical properties of model synthetic tendons10.1002/jbm.820150204 ↗
9. Migliaresi C, Ambrosio L, Guida G, Kolarik J, Nicolais L, Ronca D. A polyester fiber reinforced poly-2-hydroxymethyl methacrylate artificial tendon. In: Proceedings of the 2nd world congress on biomaterials, Washington (USA); April 27–May 1, 1984.
10. A biodegradable composite artificial tendon10.1007/BF00705368 ↗
11. Surface oxidation of polyethylene fiber reinforced polyolefin biomedical composites and its effect on cell attachment10.1023/A:1014789815441 ↗
12. Structure-mechanical properties relationship of natural tendons and ligaments10.1007/BF00122175 ↗
13. Prosthetic replacement for the anterior cruciate ligament
14. Viscoelastic behavior of composite ligament prostheses10.1002/(SICI)1097-4636(199810)42:1<6::AID-JBM2>3.0.CO;2-U ↗
15. Continuous-glass-fibre-reinforced polypropylene composites II. Influence of maleic-anhydride modified polypropylene on fatigue behaviour10.1016/S1359-835X(97)00089-4 ↗
16. Fatigue mechanisms in unidirectional glass-fibre-reinforced polypropylene10.1016/S0266-3538(98)00119-5 ↗
17. A review of methods for improving the interfacial adhesion between carbon fiber and polymer matrix10.1002/pc.10265 ↗
18. The influence of fibre surface properties on the mode of failure in carbon–fibre/epoxy composites10.1016/S0266-3538(98)00012-8 ↗
19. Oxygen plasma treatment of high performance fibers for composites10.1016/j.matchemphys.2003.12.004 ↗
20. Non-destructive evaluation of interfacial damage properties for plasma-treated biodegradable poly(p-dioxanone) fiber/poly(l-lactide) composites by micromechanical test and surface wettability10.1016/j.compscitech.2003.09.009 ↗
21. Composites of UHMW polyethylene fibres in a LD polyethylene matrix. I. Processing conditions10.1016/S0266-3538(98)00090-6 ↗
22. The effect of the oxygen-plasma treatment of UHMWPE fiber on the transverse properties of UHMWPE-fiber/vinylester composites10.1016/S0266-3538(98)00093-1 ↗
23. A study of the impact properties of surface-modified UHMPE-fiber/vinylester composites10.1016/S0266-3538(96)00130-3 ↗
24. Surface energy increase of oxygen-plasma-treated PET10.1016/S1044-5803(03)00094-9 ↗
25. Utilization of composite laminate theory in the design of synthetic soft tissues for biomedical prostheses10.1016/0142-9612(90)90076-3 ↗
26. Mechanical behavior of composite artificial tendons and ligaments10.1016/0142-9612(95)99693-G ↗
27. Vena P, Contro R, Pietrabissa R, Ambrosio L. Design of materials subject to bio-mechanical compatibility constraints. In: Synthesis in bio solid mechanics, Proceedings of the IUTAM symposium; 1998. p. 67–78.10.1007/0-306-46939-1_7 ↗
28. Three-dimensional deformation and stress distribution in an analytical/computational model of the anterior cruciate ligament10.1016/S0021-9290(00)00073-7 ↗
29. A theory of large elastic deformation10.1063/1.1712836 ↗
30. Large elastic deformations of isotropic materials IV. Further developments of the general theory10.1098/rsta.1948.0024 ↗
31. Holzapfel · 2000
32. Modelling the effective elasto-plastic properties of unidirectional composites reinforced by fibre bundles under transverse tension and shear loading10.1016/S0921-5093(02)00399-4 ↗
33. Hyper-elastic model analysis of anterior cruciate ligament10.1016/S1350-4533(96)00077-X ↗