Rapid and nondestructive analysis of quality of prepreg cloth by near-infrared spectroscopy
Source abstract
Abstract
Abstract A near-infrared spectroscopy analysis technique has been developed to measure the resin content, the volatile content and the pre-curing degree of resin during the manufacture of prepreg cloth by solution impregnation process. A principal components regression (PCR) algorithm was used to model the relation between the components content and the spectra. The calibration results had correlation coefficient of 0.9440 for the resin content (root mean square error of calibration, RMSEC = 0.490), of 0.9417 for the volatile content (RMSEC = 0.249) and of 0.9401 for the pre-curing degree (RMSEC = 0.186), respectively. The method was applied in the product line to analyze the quality of prepreg cloth directly, and the measurement process was accomplished in less than 2 min without sample destruction. The results showed that the maximal error were −0.70%, −0.546% and 0.378% for the resin content, the volatile content and the pre-curing degree, respectively. The study indicates that NIR spectroscopic method is a good alternative for the quality analysis of prepreg cloth.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spectroscopy and Chemometric Analyses · Spectroscopy Techniques in Biomedical and Chemical Research · Cultural Heritage Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. The quality control and non-destructive evaluation of composite aerospace components10.1016/S0010-4361(83)80007-X ↗
2. The development of a portable ultrasonic facility for NDT of graphite/epoxy composites
3. Evaluation of electrostatic air coupled ultrasonic technology for measuring changes in resin content in carbon prepreg tow materials
4. Smithgall FB. Automatic inspection of advanced composite tape. In: 35th International SAMPE symposium; 1990. p. 1880–91
5. Menson S. Sensors for monitoring carbon composite cured and resin content measurement in carbon prepreg tow for infrastructure application. In: Advanced Technology Program (ATP) Workshop on composite in civil application, Civil Infrastructure Session, Washington, DC, USA; 1998. p. 78–99
6. Prepreg tape and fabric technology for advanced composites10.1016/S0010-4361(83)80003-2 ↗
7. On-line monitoring of resin content for film impregnation process10.1016/S0266-3538(97)00185-1 ↗
8. Moe AL, Konicek JD. Process for measurement of the degree of cure and percent resin of glass-fiber reinforced epoxy resin prepreg. US Patent 5,457,319, 1995
9. Monitoring of the polymerization of vinyl acetate by near-IR FT Raman spectroscopy10.1016/S1386-1425(97)83003-X ↗
10. Near-infrared spectroscopy for polymer reaction and process control: synthesis, processing and recycling10.1255/nirn.283 ↗
11. Determination of moisture in polymers using NIR procedures
12. Near-infrared analysis of chemical constituents and physical characteristics of polymers
13. Application of NIRA techniques for the determination of polymer end and functional groups10.1002/pola.1988.080260705 ↗
14. Determination of polymorphic purity by near-infrared spectrometry10.1016/S0003-2670(99)00828-4 ↗
15. The application of near-infrared spectroscopy for the quality control analysis of rocket propellant fuel pre-mixes10.1016/j.talanta.2003.08.037 ↗
16. Dispersive and Fourier transform near-infrared spectroscopy of polymeric materials10.1016/0924-2031(94)00054-K ↗
17. Extension of sample sizes and percentage paints for significance tests of outlying observations10.2307/1267134 ↗