journal article·2002-07

Analyses of composite insulators with crimped end-fittings: part II—Suitable crimping conditions

M Kumosa, D Armentrout, L Kumosa, Y Han, S.H Carpenter

Composites Science and Technology· Volume 62· Issue 9
Publisher page

Abstract

In this research the mechanical behavior of composite suspension insulators with crimped end-fittings manufactured by NGK has been evaluated. Two issues have been addressed in this study. Insulators crimped with the standard, high, reversed and constant high stress conditions have been analyzed for their crimping deformations, and the two and three dimensional compression profiles for the four different crimping conditions have been determined. Second, a series of mechanical tests has been performed by subjecting the insulators to excessive tensile axial loads until failure. Acoustic emission (AE) was also monitored during the tests. It has been found that the shape of the compression profiles is dependent on the manufacturing crimping process. The magnitudes of compression for the standard, high, reversed and constant high stress conditions are almost the same, with the distribution of compression along the fitting being noticeably different for each stress condition. The results from the pull-out tests clearly demonstrate that the crimping process can significantly effect the mechanical strength of the insulators. The insulators with the standard controlled stress conditions failed by rod pull-out whereas the other crimping conditions resulted in rod fracture. It has been shown in this study that the mechanical strength of crimped insulators can be optimized to avoid both crushing of the glass reinforced polymer (GRP) rods due to crimping and rod fracture under excessive tensile loads.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete · High voltage insulation and dielectric phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. Kumosa M, Han Y, Kumosa L. Analyses of composite insulators with crimped end-fittings: part I—non linear finite element computations. Composites Science and Technology 2002;62:1191–1207.10.1016/S0266-3538(02)00066-0 ↗
2. Kumosa M. Analytical and experimental studies of substation NCIs [Final Report to the Bonneville Power Administration]. Oregon Graduate Institute of Science & Technology, Portland, Oregon; 1994.
3. Finite element analysis of substation composite insulators10.1016/0266-3538(95)00120-4 ↗
4. Bansal A. Finite element simulation and mechanical characterization of composite insulators, PhD dissertation. Oregon Graduate Institute of Science & Technology, Portland, Oregon; 1996.
5. Mechanical evaluation of axially loaded composite insulators with crimped end-fittings10.1177/002199839703102004 ↗
6. Kumosa M, Han Y, Carpenter SH, Armentrout D, Kumosa L. Suitable crimping conditions in composite suspension high voltage insulators [Final Report to NGK Insulators, Ltd]; 1998.
7. Kumosa M. et al. Fracture analysis of composite insulators [Final Report to the Electric Power Research Institute, 1006293]. October 2001.
8. Kumosa, L. An evaluation of available methods for the determination of crimping profiles, Internal Report, University of Denver, 1999.