The design and prototype manufacture of a controlled-stiffness composite femoral prosthesis is described. The prosthesis is composed of a cobalt-chrome core surrounded by a flexible composite outer layer. By varying the composite layer thickness it was possible to control the prosthesis stiffness. The new design was critically assessed by means of finite-element method and its predicted performance compared with those of conventional, single-modulus prostheses. A simple model based on composite beam theory was used to determine the optimum thickness of the composite material. The composite was made of an epoxy resin reinforced with braided hybrid carbon-glass pre-forms. A prototype incorporating the novel concept design was manufactured by using the compression moulding technique.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Early failures among 14009 cemented and 1326 uncemented prostheses for primary coarthrosis10.3109/17453679408993706 ↗
2. Failed innovation in total hip replacement10.3109/17453679308994602 ↗
3. Cementless fixation of ‘isoelastic’ hip endoprostheses manufactured from plastic materials
4. The isoelastic hip prosthesis followed for 5 years10.3109/17453678809149357 ↗
5. In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis10.1097/00003086-199108000-00031 ↗
6. A prospective comparison of Butel and PCA hip arthroplasty10.1302/0301-620X.75B4.8331120 ↗
7. The isoelastic non-cemented total hip arthroplasty: preliminary experience with 400 cases10.1097/00003086-198605000-00025 ↗
8. The 5 to 7 year follow-up results with the RM isoelastic hip prosthesis
9. Total hip arthroplasty using isoelastic femoral stems. A seven-to-nine year follow-up in 108 patients10.1302/0301-620X.76B3.8175844 ↗
10. Development of a carbon-carbon hip prosthesis10.1002/j.1097-4636.1987.tb00018.x ↗
11. Implant stability, histology, RSA and wear-more critical questions are needed10.3109/17453679408994626 ↗
12. Observations on the effect of movement on bone ingrowth into porous-surfaced implants10.1097/00003086-198607000-00023 ↗
13. Preliminary investigation of a novel controlled stiffness proximal prosthesis10.1243/0954411981533944 ↗
14. Kuiper JH, Huiskes R. Numerical optimization of hip-prosthetic stem material. In: Middleton et al., editors. Computer methods in biomechanics and biomedicine, 1993. p. 76–84.
15. Simões JAO, António CAC, Marques AT. Material stiffness optimization for a composite hip prosthesis. In: S Adali, VE Verijienko, editors. 1st International Conference on Composite Science and Technology, Durban, South Africa, Department of Mechanical Engineering, University of Natal, 1996. p. 477–82.
16. Simões JA, Taylor M. Comparison of conventional and hybrid modulus pres-fit proximal femoral prostheses. In: M Cerrolaza, D Jugo, CA Brebbia, editors. Simulation modelling in bioengineering. Computational Mechanics Publications, 1996. p. 127–39.
17. Kuiper JH. Numerical optimization of artificial hip joint designs. Ph.D. thesis, Katholieke Universiteit Nijmegen, The Netherlands, 1993.
18. Mathematical shape optimization of hip prosthesis design10.1016/0021-9290(89)90063-8 ↗
19. Katoozian H, Davy DT. Three-dimensional shape optimization of femoral components of total hip prostheses. In: 1993 ASME Bioengineering Conference, BED, Vol. 24, 1993. p. 552–5.
20. Blake TA, Davy DT, Saravanos DA, Hopkins DA. Numerical optimization of composite hip endoprostheses. In: Proceedings of 4th AIAA/USAF/NASA/OAI symposium on multidisciplinary analysis and optimization, 1992. p. 119–29.10.2514/6.1992-4703 ↗
21. Shape optimal design of the stem of a cemented hip prosthesis to minimize stress concentration in the cemented layer10.1016/0021-9290(89)90231-5 ↗
22. Davidson R, Brabon S, Lee RJ, Nelson K, Unwin P, Roughley P. The development of CFRP based hip stems. In: Proceedings of the 7th European conference on composite materials, ECCM-7, London, 1996. p. 513–17.
23. Widmer M, Callenbach T, Isler J, Fröhlich M, Meier D, Mayer J, et al. Injection moulding of carbon fibre reinforced PEEK for anisotropic hip-prostheses: Preliminary results. In: Proceedings of the III Portuguese Congress in Biomedical Engineering, Porto, 1995.
24. Devanathan D. Orthopaedic composites. In: Lee SM, editor. International encyclopedia of composites, Vol. 4. New York, 1991. p. 74–86.
25. Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials10.1002/jbm.820240707 ↗
26. Scheer W. Carbon fibre reinforced epoxy resin, a material for human implants. In: Processing and uses of carbon fibre reinforced plastics. Düsseldorf: VDI-Verlag GmbH, Verlag des Vereins Deutscher Ingenieure, 1981. p. 251–76.
27. Claes I, Burri C, Neugebauer R, Gruber U. Experimental investigations on hip prostheses with carbon fibre reinforced carbon shafts and ceramic heads. In: P. Vincenzini, editor. Ceramics in Surgery. Amsterdam, 1983. p. 243–50.
28. Hochman RF. US patent 3, 893, 196, 1975.
29. Turner RM, et al. US patent 4, 662, 887, 1987.
30. Effects of composite laminate lay-up configuration of a canine composite hip stem on bone strains. BED, Advances in Bioengineering,
31. A canine composite femoral stem10.1097/00003086-198810000-00023 ↗
32. Simões JA, Vaz MA, Marques AT, Silva Gomes J. Development of a controlled stiffness composite femoral prosthesis. In: CR Gentle, JB Hull, editors. Mechanics in design '98, Nottingham, United Kingdom, 1998. p. 600–8.
33. Finite element modelling — a predictor of implant survival?10.1007/BF00134322 ↗
34. Cancelous bone stresses surrounding the femoral component of a hip prosthesis10.1016/1350-4533(95)00018-I ↗
35. Fatigue failure of cancellous bone10.1302/0301-620X.79B2.7461 ↗
36. Stress pattern around femoral stems10.1097/00003086-199012000-00006 ↗
37. Early migration and late aseptic failure of proximal femoral prostheses10.1302/0301-620X.76B3.8175848 ↗
38. Does early micromotion of the femoral stem prostheses matter10.1302/0301-620X.76B6.7983118 ↗
39. Prediction of clinical outcome of THR from migration measurements on standard radiographs10.1302/0301-620X.77B5.7559694 ↗
40. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens10.1016/0021-9290(92)90255-Y ↗
41. Compressive fatigue behaviour of bovine trabecular bone10.1016/0021-9290(93)90009-4 ↗
42. Simões JAO. Desenvolvimento da componente femoral de uma prótese de anca de rigidez controlada. Translation: Development of controlled stiffness proximal femoral prosthesis. Ph.D. thesis, Department of Mechanical Engineering and Industrial Management, University of Porto, 1999.
43. Prognosis of total hip replacement in Sweden10.3109/17453679308993679 ↗