journal article·2013-06

Partial volume correction for approximating crack opening displacements in CFRP material obtained from micro-focus X-ray CT scans

D.J. Bull, I. Sinclair, S.M. Spearing

Publisher page

Abstract

Abstract This paper presents a partial volume correction technique that applies a measurement weighting based on grey scale intensity values, allowing crack opening displacements (CODs) to be better estimated in micro-focus computed tomography (μCT) scans. These were tested on 3D data obtained from two separate μCT scanners on particle toughened and non-particle toughened carbon fibre material subjected to low velocity impact. Direct comparisons of COD estimations were made with higher resolution measurements obtained using synchrotron radiation computed tomography (SRCT) scans taken at the European Synchrotron Radiation Facility (ESRF). In this study, partial volume correction is reported to improve the accuracy of these measurements to within 20% of SRCT measurements, whereas measurements based on counting interconnected voxels representing a detectable crack are reported to consistently overestimate crack openings by up to 500%. Scatter in estimations was dependent on material type, noise, and artefacts associated with μCT volumes.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Advanced X-ray Imaging Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Nondestructive evaluation of composites using micro-focused X-ray CT scanner10.1063/1.1916792 ↗
2. X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites10.1016/j.compscitech.2005.05.014 ↗
3. X-ray radiography and micro-computed tomography examination of damage characteristics in stitched composites subjected to impact loading10.1016/j.compositesb.2011.01.011 ↗
4. Impact damage assessment of composites
5. Application of X-ray tomography to the nondestructive testing of high-performance polymer composites
6. Impact properties of weft knitted fabric reinforced composites10.1016/S0266-3538(02)00057-X ↗
7. Effect of glass fiber hybridization on the behavior under impact of woven carbon fiber/epoxy laminates10.1177/0021998310369602 ↗
8. The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
9. High resolution tomographic imaging and modelling of notch tip damage in a laminated composite10.1016/j.compscitech.2010.04.012 ↗
10. Crack opening displacements during fatigue crack growth in Ti–SiC fibre metal matrix composites by X-ray tomography10.1179/174328406X114108 ↗
11. Quantitation in positron emission computed-tomography. 1. Effect of object size10.1097/00004728-197906000-00001 ↗
12. The influence of partial volume averaging on sphere detectability in computed-tomography10.1088/0031-9155/26/5/011 ↗
13. Artifacts in CT: recognition and avoidance10.1148/rg.246045065 ↗
14. Towards high performance digital volume correlation10.1007/s11340-010-9445-0 ↗
15. In Situ experiments with X-ray tomography: an attractive tool for experimental mechanics10.1007/s11340-010-9333-7 ↗
16. Partial-volume effect in PET tumor imaging10.2967/jnumed.106.035774 ↗
17. Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems10.1590/S0103-64402009000500004 ↗
18. Current methods in medical image segmentation10.1146/annurev.bioeng.2.1.315 ↗
19. Partial volume correction for volume estimation of liver metastases and lymph nodes in CT scans using spatial subdivision
20. Measuring small airways in transverse CT images: correction for partial volume averaging and airway tilt10.1016/j.acra.2010.08.005 ↗
21. MicroCT (microtomography) quantification of microstructure related to macroscopic behaviour – Part 1 – Fatigue crack closure measured in situ in AA 2090 compact tension samples10.1179/174328406X114144 ↗
22. New direct observations of crack closure processes in Al–Li 2090 T8E4110.1098/rsta.1999.0464 ↗
23. Direct observation of crack opening as a function of applied load in the interior of a notched tensile sample of Al–Li 209010.1016/S1359-6454(96)00311-4 ↗
24. Compression after impact of thin composite laminates10.1016/j.compscitech.2005.04.009 ↗
25. A test object with parallel grooves for calibration and accuracy assessment of industrial computed tomography (CT) metrology10.1088/0957-0233/22/11/115502 ↗