journal article·2005-11

Memorizing maximum strain in carbon-fiber-reinforced plastic composites by measuring electrical resistance under pre-tensile stress

Yoshiki Okuhara, Hideaki Matsubara

Composites Science and Technology· Volume 65· Issue 14
Publisher page

Abstract

Abstract Electrical resistance change of fiber-reinforced plastics including continuous carbon fibers has been characterized in tensile tests, in order to provide the composite with the ability to memorize maximum strain. The composites were designed to exhibit obvious residual resistance resulting from fiber fracture, by which maximum strain was memorized after loading–unloading cycles. The composite with a lower volume fraction of carbon fibers was found to be suitable for showing larger resistance change in wider strain range. In order to maintain the increased resistance even after unloading, it was proposed to utilize the composites under pre-stressed condition. The cyclic tensile tests revealed that the pre-stressed composites indicated good sensitivity concerning lower detectable strain limit of less than 0.05% and remarkable residual resistance which brought about memorizing accuracy within ±1%. The applicability of the memorizing capability was demonstrated in a bending test for a concrete beam including the pre-stressed composite.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Smart Materials for Construction · Structural Health Monitoring Techniques · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Fiber optic sensors in concrete structures: a review10.1088/0964-1726/5/2/008 ↗
2. Shculte K, Wittich H. The electrical response of strained and/or damaged polymer matrix composites. In: Proceedings on international conference on composite materials (ICCM)-10, vol. 5, Whistler, Canada; 1995. p. 349–56.
3. Sensing with carbon fibers in polymer composites
4. Foreseeing of fracture in CFGFRP composites by the measurement of residual change in electrical resistance10.2109/jcersj.100.585 ↗
5. Preventing fatal fractures in carbon-fiber–glass-fiber reinforced plastic composites by monitoring change in electrical resistance10.1111/j.1151-2916.1993.tb05309.x ↗
6. Fatigue damage characterization in carbon fiber composite materials using an electrical potential technique10.1088/0964-1726/7/4/004 ↗
7. Song DY, Takeda N, Kitano A, Yoshioka K. Quantitative evaluation of CFRP and CFGFRP hybrid composites as a maximum strain memory sensor. In: Proceedings of SPIE, smart structures and materials, vol. 3986, Newport Beach (CA); 2000. p. 232–9.10.1117/12.388111 ↗
8. Park JB, Okabe T, Song DY, Takeda N, Kitano A. In-situ health monitoring of CFRP composites using electrical characteristics. In: Proceedings of SPIE, Smart Structures and Materials, vol. 4328, Newport Beach (CA); 2001. p. 323–31.10.1117/12.435535 ↗
9. Structural health monitoring by electrical resistance measurement10.1088/0964-1726/10/4/305 ↗
10. Self-monitoring, pseudo-ductile, hybrid FRP reinforcement rods for concrete applications10.1016/S0266-3538(00)00184-6 ↗
11. Self-diagnosis of fiber reinforced composites using electrical conductivity
12. Fracture detection function of the composite of glass fiber, plastics and carbon powder10.6089/jscm.25.225 ↗
13. Self-diagnosis of the composite containing electrically conductive phase
14. Matsubara H, Shin SG, Okuhara Y, Nomura H, Yanagida H. Application of the self diagnosis composite into concrete structure. In: Proceedings of SPIE, smart structures and materials, vol. 4234, Melbourne; 2000. p. 36–43.10.1117/12.424385 ↗
15. Okuhara Y, Shin SG, Matsubara H, Yanagida H, Takeda N. Development of conductive FRP containing carbon phase for self-diagnosis structures. In: Proceedings of SPIE, smart structures and materials, vol. 4328, Newport Beach (CA); 2001. p. 314–22.10.1117/12.435534 ↗
16. Design of self-diagnosis composites and their application to health monitoring of concrete structures
17. Performance of concrete beams prestressed with aramid fiber-reinforced polymer tendons10.1016/S0263-8223(98)00126-3 ↗
18. Evaluation of deflection in concrete members reinforced with fiber reinforced polymer (FRP) bars10.1016/S0263-8223(01)00188-X ↗
19. Nondestructive evaluation on damage of carbon fiber sheet reinforced concrete10.1016/S0263-8223(02)00029-6 ↗
20. TDR monitoring for integrity of structural systems10.1061/(ASCE)1076-0342(2000)6:2(67) ↗