journal article·2018-02

Effect of electrical stress on glass fiber reinforced polymer used in high voltage composite insulator under wet environment

Yanfeng Gao, Xidong Liang, Yingyan Liu, Weining Bao, Shaohua Li, Chao Wu

Publisher page

Abstract

Abstract The effect of electrical stress on glass fiber reinforced polymer under wet condition has been investigated in the present study. A specially designed and fabricated test setup was used through which the current passing through the GFRP rod during the test was recorded. Based on the changes in morphology of GFRP rod surface and development trend of current, the degradation process of GFRP rod caused by electrical stress under wet condition was divided into four consecutive stages, namely degradation inception stage, hydrolysis stage, carbonization stage and breakdown stage. Scanning electron microscopy (SEM), Fourier transform infrared (FTIR), thermogravimetric analysis (TGA) and X-ray Photoelectron Spectroscopy (XPS) analyses were employed to provide the physical and chemical properties of GFRP at different stages. The results showed that the degradation process of GFRP caused by electrical stress under wet condition progressively developed in the form of degraded channel, in which the epoxy resin matrix deteriorated significantly. The occurrences of hydrolysis, oxidation, pyrolysis and carbonization of epoxy resin matrix could be observed sequentially in the degradation process of GFRP during the test. With the development of the degradation process of GFRP, the content of epoxy resin matrix continued to decrease and the relative content of highly oxidized carbons (C-O, C=O and O-C=O) in epoxy resin matrix on GFRP surface increased before the carbonization process and then decreased in the carbonization process. The present study is helpful for better understanding of the electrical performance of GFRP used in high voltage composite insulator as well as in other electrical applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Electrical Fault Detection and Protection · Dielectric materials and actuators

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. 50 years in the development of polymer suspension-type insulators10.1109/MEI.2013.6507410 ↗
2. Development of composite insulators in China10.1109/94.798115 ↗
3. Outdoor HV composite polymeric insulators10.1109/TDEI.1999.9286745 ↗
4. Failure analyses of nonceramic insulators. Part 1: brittle fracture characteristics10.1109/MEI.2005.1437604 ↗
5. Modern outdoor insulation-concerns and challenges10.1109/MEI.2005.1541483 ↗
6. Schmuck · 2012
7. Papailiou · 2012
8. Moisture absorption properties of unidirectional glass/polymer composites used in composite (non-ceramic) insulators10.1016/j.compositesa.2004.03.008 ↗
9. Accelerated environmental ageing study of polyester/glass fiber reinforced composites (GFRPCs)10.1016/j.compositesb.2006.10.004 ↗
10. Moisture diffusion and hygrothermal aging of pultruded glass fiber reinforced polymer laminates in bridge application10.1016/j.compositesb.2016.04.085 ↗
11. Water diffusion into and electrical testing of composite insulator GRP rods10.1109/TDEI.2004.1306729 ↗
12. Moisture-induced degradation of interfacial bond in FRP-strengthened masonry10.1016/j.compositesb.2015.10.022 ↗
13. Failure analyses of nonceramic insulators: Part II-The brittle fracture model and failure prevention10.1109/MEI.2005.1489987 ↗
14. Electric field analysis of water drop corona10.1109/TPWRD.2004.837672 ↗
15. Electric fields on AC composite transmission line insulators10.1109/TPWRD.2007.911127 ↗
16. Failure of high voltage electrical insulators with pultruded glass fibre-reinforced plastic cores10.1016/0010-4361(86)91005-0 ↗
17. Metallographic investigation of the damage caused to GRP by the combined action of electrical, mechanical and chemical environments10.1007/BF00563057 ↗
18. Analysis of a fractured 500 kV composite insulator - identification of aging mechanisms and their causes10.1109/TDEI.2012.6311521 ↗
19. Failure analysis of decay-like fracture of composite insulator10.1109/TDEI.2014.004485 ↗
20. Lightning strike protection of composites10.1016/j.paerosci.2013.07.002 ↗
21. Experimental study of damage characteristics of carbon woven fabric/epoxy laminates subjected to lightning strike10.1016/j.compositesa.2015.09.019 ↗
22. Coupled thermal–electrical analysis for carbon fiber/epoxy composites exposed to simulated lightning current10.1016/j.compositesa.2010.04.001 ↗
23. Artificial lightning testing on graphite/epoxy composite laminate10.1016/j.compositesa.2010.06.008 ↗
24. Damage resistance and tolerance of carbon/epoxy composite coupons subjected to simulated lightning strike10.1016/j.compositesa.2009.04.025 ↗
25. IEC 60815–1 · 2002
26. Liang · 2015
27. Dissado · 1992
28. FTIR analysis of non-ceramic composite insulators10.1109/TDEI.2004.1324348 ↗
29. Griffiths · 2007
30. Infrared studies on polymorphs of silicon dioxide and germanium dioxide10.6028/jres.061.009 ↗
31. Mechanism of brittle fracture in nonceramic insulators10.1109/94.993741 ↗
32. Loewenstein · 1973
33. A technique for determining fiber content in FRP by thermogravimetric analyzer10.1016/j.polymertesting.2004.10.002 ↗
34. Practical surface analysis
35. Influence of the iron oxide Acid−Base properties on the chemisorption of model epoxy compounds studied by XPS10.1021/jp072354j ↗
36. Studies on adhesion characteristics and corrosion behaviour of vinyltriethoxysilane/epoxy coating protective system on aluminium10.1016/j.apsusc.2009.12.100 ↗
37. Electrostatically assembled layer-by-layer composites containing graphene oxide for enhanced hydrogen gas barrier application10.1016/j.compscitech.2013.10.004 ↗
38. Improved dispersion and interface in the graphene/epoxy composites via a facile surfactant-assisted process10.1016/j.compscitech.2013.04.009 ↗