Out-time effects on cure kinetics and viscosity for an out-of-autoclave (OOA) prepreg: Modelling and monitoring
Source abstract
Abstract
Abstract The processing and final part quality of out-of-autoclave (OOA) prepreg composites are strongly influenced by the thermo-chemical and thermo-mechanical properties of the resin. These properties are primarily influenced by the out-time, or room temperature exposure time, of the resin prior to cure, and by the chosen cure cycle. However, both these factors can be difficult to control. Therefore, the capacity to track the resin cure state during processing is highly desirable. In this study, neat resin and prepreg samples are aged from 0 to 7 weeks, and the resin cure kinetics and viscosity are measured using differential scanning calorimetry (DSC) and rheometry, respectively, and used to develop accurate predictive models. The dielectric properties of the resin are measured in situ, and correlations to resin cure kinetics and viscosity are developed. The study quantifies the effects of out-time on cure kinetics and viscosity, and shows that both properties can be predicted and monitored in situ with excellent accuracy.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Epoxy Resin Curing Processes · Synthesis and properties of polymers · Injection Molding Process and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Thermal models for MTM45-1 and Cycom 5320 out-of autoclave prepreg resins10.1177/0021998312440131 ↗
2. Effect of room-temperature out-time on tow impregnation in an out-of-autoclave prepreg10.1016/j.compositesa.2012.10.001 ↗
3. A study of cure kinetics by the use of dynamic differential scanning calorimetry10.1016/S0266-3538(01)00188-9 ↗
4. Cure kinetics of epoxy resin used for advanced composites10.1002/pi.1533 ↗
5. Characterization methodology of thermoset resins for the processing of composites materials – case study: CYCOM 890RTM epoxy resin10.1177/0021998309353960 ↗
6. In situ FT-IR and DSC investigation on the cure reaction of the dicyanate/diepoxide/diamine system10.1002/pi.747 ↗
7. Cure kinetics characterization and monitoring of an epoxy resin using DSC, Raman spectroscopy, and DEA10.1016/j.compositesa.2013.01.021 ↗
8. Determination of the degree of cure under dynamic and isothermal curing conditions with electrical impedance spectroscopy10.1002/polb.10676 ↗
9. Exploring equivalence of information from dielectric and calorimetric measurements of thermoset cure – a model for the relationship between curing temperature, degree of cure and electrical impedance10.1016/j.polymer.2005.05.005 ↗
10. Prepreg age monitoring via differential scanning calorimetry10.1177/0731684411431020 ↗
11. Monitoring ambient-temperature aging of a carbon–fiber/epoxy composite prepreg with photoacoustic spectroscopy10.1016/j.compositesa.2008.03.015 ↗
12. Evaluation of glass fibre/epoxy prepreg quality during storage
13. Detection of undercure in carbon–fibre/epoxy composites by dynamic mechanical thermal analysis
14. The principles of dielectric measurements for in situ monitoring of composite processing10.1016/0266-3538(93)90109-T ↗
15. Real time dielectric relaxation studies of dynamic polymeric systems10.1016/S0079-6700(02)00027-8 ↗
16. Cure monitoring of epoxy matrices for composites by ultrasonic wave propagation10.1002/(SICI)1097-4628(19990906)73:10<1969::AID-APP16>3.0.CO;2-Z ↗
17. The use of evanescent wave fluorescence spectroscopy for control of the liquid molding process10.1177/073168449601500904 ↗
18. Cytec Engineered Materials. CYCOM® 5320-1 Toughened Epoxy for Structural Applications -- Out-of-Autoclave Manufacturing; 2010.
19. Kim D, Centea T, Nutt SR. In situ dielectric monitoring of an out-of-autoclave prepreg: effects of out-time on viscosity, gelation and vitrification. Compos Sci Technol 2014 [submitted].10.1016/j.compscitech.2014.07.027 ↗