Monitoring of resin flow in the resin transfer molding (RTM) process using point-voltage sensors
Source abstract
Abstract
Abstract Multiple point-voltage sensors were used to monitor the mold filling stage of the resin transfer molding (RTM) process. Both lineal- and point-voltage sensors are electrical circuits in which the two poles of the sensor are closed when liquid thermoset resin arrives at the sensor location in the mold cavity. The electrical conductance of the liquid resin causes an increase in the output voltage, Vsens of the circuit. Although the gradually varying in situ data of a lineal sensor is more informative than a point-voltage sensor, lineal-voltage sensors might mislead the user if the resin covers the wires at multiple sections, or if the resin covers the wires starting from an unexpected section. Two kinds of sensors were developed: a set of similar, wrapped and compact lineal-voltage sensors acting as point-voltage sensors; and a point-voltage sensor with voltage amplification. Without this amplification, the increase in Vsens might be difficult to detect if the resin system has a low electrical conductivity and there is noise in the DAQ system. The accuracy and reliability of the new sensor system was verified by comparing the in situ sensor data with the visually recorded resin flow.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Photolithography Techniques · Epoxy Resin Curing Processes · Injection Molding Process and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Advani · 2003
2. Walsh S. In-situ sensors method and device. U.S. Patent 5,210,499, May 1993.
3. Fink BK, Walsh SM, DeSchepper DC, Gillespie Jr. JW, McCullough RL, Don RC, Waibel BJ. Advances in resin transfer molding flow monitoring using SMARTweave sensors. In: Proceedings of ASME international mechanical engineering congress and exposition. San Francisco, CA 69(II); 1995. p 999–1015.
4. Bradley JE, Diaz-Perez J, Gillespie Jr. JW, Fink BK. On-line process monitoring and analysis of thick-section composite parts utilizing SMARTweave in situ sensing technology. In: Proceedings of the international SAMPE symposium and exhibition; 1998. p. 254–67.
5. Cure monitoring and control
6. The development of a dielectric system for the online cure monitoring of the resin transfer molding process10.1016/S1359-835X(00)00050-6 ↗
7. Measurement of the degree of cure of glass fiber epoxy composites using dielectrometry10.1016/S0924-0136(01)00657-4 ↗
8. Dielectric cure monitoring for glass/polyester prepreg composites10.1016/S0263-8223(02)00072-7 ↗
9. Process monitoring of moulding compounds by ultrasonic measurements in a compression mould10.1016/S0963-8695(99)00029-8 ↗
10. Application of ultrasonics for the process control of resin transfer moulding (RTM)10.1016/j.polymertesting.2004.11.002 ↗
11. An analysis of the three-dimensional resin-transfer mold filling process10.1016/S0266-3538(99)00160-8 ↗
12. Fiber-optic flow and cure sensing for liquid composite molding10.1016/S0143-8166(00)00110-X ↗
13. Tuncol G, Danisman M, Kaynar A, Sozer EM. Constraints on monitoring resin flow in the resin transfer molding (RTM) process by using thermocouple sensors. Compos A: Appl Sci Manuf [submitted for publication].
14. Introduction to pressure transducers. Omega. Available from: http://www.omega.com/prodinfo/pressuretransducers.html.
15. Melt pressure transducers. Dynisco. Available from: http://www.dynisco.com/products.asp?FID=39& FNAME= Melt + Pressure + Transducers.
16. Lineal sensors for liquid injection molding of advanced composite materials
17. An approach to couple mold design and on-line control to manufacture complex composite parts by resin transfer molding10.1016/S1359-835X(02)00043-X ↗
18. Stadtfeld HC, Sozer EM, Steiner KV, Advani SG. Approach towards an automated design environment for the resin transfer molding process. In: Proceedings of the 45th International SAMPE 2000 Symposium Exhibit 2000;45(2):1576–84.
19. OPA-655, Wideband, unity gain stable, FET-input, operational amplifier, http://Focus.Ti.Com/Lit/Ds/Symlink/Opa655.Pdf.
20. National semiconductor, LM158/LM258/LM358/LM2904, Low power dual operational amplifiers, http://www.national.com/ds/LM/LM158.pdf.
21. Design and application of actively controlled injection schemes for resin-transfer molding10.1016/S0266-3538(01)00064-1 ↗
22. On-line strategic control of liquid composite mold filling process10.1016/S1359-835X(00)00060-9 ↗
23. Sozer EM, Bickerton S, Advani SG. Use of sensors and simulations for strategic control of liquid composite mold filling process. In: CMA/SME, composites manufacturing and tooling 2000 conference and tabletop exhibits. Newport Beach, California; 2000. p 167–90.
24. Experimental investigation of heat dispersion due to impregnation of viscous fluids in heated fibrous porous during composites processing10.1115/1.1338131 ↗
25. Closed-loop flow control in resin transfer molding using real-time numerical process simulations10.1016/S0266-3538(01)00213-5 ↗
26. Flow sensing and control strategies to address race-tracking disturbances in resin transfer molding. Part I. Design and algorithm development10.1016/j.compositesa.2004.03.010 ↗
27. Flow sensing and control strategies to address race-tracking disturbances in resin transfer molding. Part II. Automation and validation10.1016/j.compositesa.2004.04.009 ↗
28. Simacek P, Advani SG. Liquid injection molding simulation (LIMS). University of Delaware. http://www.ccm.udel.edu/Pubs/techbriefs/LIMS.pdf.