A method to develop mock arteries suitable for cell seeding and in-vitro cell culture experiments
Source abstract
Abstract
Sylgard((R)) is a biocompatible elastomer which has been widely used in biomedical applications including in simulations of the mechanical response of soft tissues and mechanotransduction investigations. In this study the effect of fabrication parameters including base to curing agent ratio and curing time on the mechanical response of Sylgard((R)) was investigated and a novel fabrication technique for the production of mock arteries with highly uniform thickness, which is essential for mechanotransduction studies, is described. Finally a method for the surface treatment of Sylgard((R)) using sulphuric acid and fibronectin to enhance smooth muscle cell (SMC) adhesion is proposed and examined in vitro. Sylgard((R)) mock coronary arteries fabricated using the proposed technique exhibited a mechanical response close to arterial tissue with cell adhesion enhanced using the surface treatment techniques described.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · 3D Printing in Biomedical Research · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. Evaluation of polydimethylsiloxane scaffolds physiologically relevant elastic moduli: interplay of substrate mechanics and surface chemistry effects on vascular smooth muscle cell response10.1016/j.biomaterials.2004.08.009 ↗
2. An in vitro model and its application for the study of carotid Doppler spectral broadening10.1016/0301-5629(83)90087-X ↗
3. Development of a three-dimensional physiological model of the internal anal sphincter bioengineered in vitro from isolated smooth muscle cells10.1152/ajpgi.00335.2004 ↗
4. Liepsch, D., Moravec, S., Baumgart, R., (1992). Some flow visualization and laser-Doppler-velocity measurements in a true-to-scale elastic model of a human aortic arch—a new model technique.10.3233/BIR-1992-295-615 ↗
5. A versatile test object for the calibration of ultrasonic Doppler flow instruments10.1016/0301-5629(86)90315-7 ↗
6. A device for subjecting vascular endothelial cells to both fluid shear stress and circumferential cyclic stretch10.1007/BF02368248 ↗
7. Characterization of adhesion at solid surfaces: development of an adhesion-testing device10.1016/j.eurpolymj.2005.06.008 ↗
8. Comparison of radial expansion of stents within mock vessels molded with a target bent radius versus straight mock vessels bent to a target radius
9. Linear elastic mechanics of mock arteries: empirical versus theoretically predicted pulsatile stent deflection
10. Mechanical properties of porcine and human arteries: implications for coronary anastomotic connectors10.1016/S0003-4975(03)00263-7 ↗
11. Measurement of vessel wall strain using cine phase contrast MRI10.1002/jmri.10077 ↗