Optimization of the failure criterion in micro-Finite Element models of the mouse tibia for the non-invasive prediction of its failure load in preclinical applications

S. Oliviero, R. Owen, G.C. Reilly, I. Bellantuono, E. Dall'Ara

Abstract

New treatments against osteoporosis require testing in animal models and the mouse tibia is among the most common studied anatomical sites. In vivo micro-Computed Tomography (microCT) based micro-Finite Element (microFE) models can be used for predicting the bone strength non-invasively, after proper validation against experiments. The aim of this study was to evaluate the ability of different microCT-based bone parameters and microFE models to predict tibial structural mechanical properties in compression. Twenty tibiae were scanned at 10.4 μm voxel size and subsequently tested in uniaxial compression at 0.03 mm/s until failure. Stiffness and failure load were measured from the load-displacement curves. Standard morphometric parameters were measured from the microCT images. The spatial distribution of bone mineral content (BMC) was evaluated by dividing the tibia into 40 regions. MicroFE models were generated by converting each microCT image into a voxel-based mesh with homogeneous isotropic material properties. Failure load was estimated by using different failure criteria, and the optimized parameters were selected by minimising the errors with respect to experimental measurements. Experimental and predicted stiffness were moderately correlated (R2 = 0.65, error = 14% ± 8%). Normalized failure load was best predicted by microFE models (R2 = 0.81, error = 9% ± 6%). Failure load was not correlated to the morphometric parameters and weakly correlated with some geometrical parameters (R2 < 0.37). In conclusion, microFE models can improve the current estimation of the mouse tibia structural properties and in this study an optimal failure criterion has been defined. Since it is a non-invasive method, this approach can be applied longitudinally for evaluating temporal changes in the bone strength.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone health and osteoporosis research · Orthopaedic implants and arthroplasty · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
2. Comparison of strain measurement in the mouse forearm using subject-specific finite element models, strain gaging, and digital image correlation10.1007/s10237-017-0885-7 ↗
3. Mineralizing surface is the main target of mechanical stimulation independent of age: 3d dynamic in vivo morphometry10.1016/j.bone.2014.05.013 ↗
4. Guidelines for assessment of bone microstructure in rodents using micro–computed tomography10.1002/jbmr.141 ↗
5. Micro-Ct based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study10.1016/j.jmbbm.2016.09.014 ↗
6. A novel algorithm to predict bone changes in the mouse tibia properties under physiological conditions10.1007/s10237-019-01266-7 ↗
7. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice10.1016/j.bonr.2016.05.006 ↗
8. Micro Finite Element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
9. Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography10.1016/S8756-3282(03)00210-2 ↗
10. A nonlinear Qct-based finite element model validation study for the human femur tested in two configurations in vitro10.1016/j.bone.2012.09.006 ↗
11. Longitudinal imaging of the ageing mouse10.1016/j.mad.2016.08.001 ↗
12. Qct-based finite element models predict human vertebral strength in vitro significantly better than simulated Dexa10.1007/s00198-011-1568-3 ↗
13. Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements10.1016/j.jmbbm.2016.10.002 ↗
14. Adaptation of tibial structure and strength to axial compression depends on loading history in both C57bl/6 and Balb/c mice10.1007/s00223-013-9744-4 ↗
15. Establishing biomechanical mechanisms in mouse models: practical guidelines for systematically evaluating phenotypic changes in the diaphyses of long bones10.1002/jbmr.2539 ↗
16. Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: comparison with synchrotron radiation microcomputed tomography and ash measurements10.1118/1.2924210 ↗
17. Femoral and vertebral strength improvements in postmenopausal women with osteoporosis treated with denosumab10.1002/jbmr.2024 ↗
18. Development of a protocol to quantify local bone adaptation over space and time: quantification of reproducibility10.1016/j.jbiomech.2016.05.022 ↗
19. Longitudinal effects of Parathyroid Hormone treatment on morphological, densitometric and mechanical properties of mouse tibia10.1016/j.jmbbm.2017.07.034 ↗
20. Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method10.1016/j.bone.2008.01.017 ↗
21. Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis10.1038/bonekey.2015.31 ↗
22. Validation of finite element models of the mouse tibia using digital volume correlation10.1016/j.jmbbm.2018.06.022 ↗
23. Effect of repeated in vivo microct imaging on the properties of the mouse tibia10.1371/journal.pone.0225127 ↗
24. Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia10.1016/j.jbiomech.2017.10.026 ↗
25. Experimental and finite element analysis of strains induced by axial tibial compression in young-adult and old female C57bl/6 mice10.1016/j.jbiomech.2013.10.052 ↗
26. Regional nanoindentation properties in different locations on the mouse tibia from C57bl/6 and balb/C female mice10.3389/fbioe.2020.00478 ↗
27. Predicting cortical bone adaptation to axial loading in the mouse tibia10.1098/rsif.2015.0590 ↗
28. Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images10.1016/S8756-3282(02)00736-6 ↗
29. Prediction of hip failure load: in vitro study of 80 femurs using three imaging methods and finite element models—the European fracture study (effect)10.1148/radiol.2016142796 ↗
30. Patient-specific finite element estimated femur strength as a predictor of the risk of hip fracture: the effect of methodological determinants10.1007/s00198-016-3597-4 ↗
31. Skeletal maturity leads to a reduction in the strain magnitudes induced within the bone: a murine tibia study10.1016/j.actbio.2014.11.021 ↗
32. The longitudinal effects of ovariectomy on the morphometric, densitometric and mechanical properties in the murine tibia: a comparison between two mouse strains10.1016/j.bone.2019.06.024 ↗
33. An accurate estimation of bone density improves the accuracy of subject-specific finite element models10.1016/j.jbiomech.2008.05.017 ↗
34. Experimental validation of a nonlinear μfe model based on cohesive-frictional plasticity for trabecular bone10.1002/cnm.2739 ↗
35. Validation of an Hr-pqct-based homogenized finite element approach using mechanical testing of ultra-distal radius sections10.1007/s10237-010-0245-3 ↗
36. Finite element analysis of bone strength in osteogenesis imperfecta10.1016/j.bone.2020.115250 ↗
37. From bed to bench: how in silico medicine can help ageing research10.1016/j.mad.2018.07.001 ↗
38. Major source of error when calculating bone mechanical properties10.1002/jbmr.2304 ↗
39. Valid μ finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions10.1016/j.jbiomech.2010.02.026 ↗
40. Examining tissue composition, whole-bone morphology and mechanical behavior of Gorabprx1 mice tibiae: a mouse model of premature aging10.1016/j.jbiomech.2017.10.018 ↗
41. Standardizing compression testing for measuring the stiffness of human bone10.1302/2046-3758.78.BJR-2018-0025.R1 ↗
42. Comparison of proximal femur and vertebral body strength improvements in the Freedom trial using an alternative finite element methodology10.1016/j.bone.2015.06.025 ↗
43. Finite element analysis for prediction of bone strength10.1038/bonekey.2013.120 ↗