journal article·2017-04

Effect of contact stress on the cycle-dependent wear behavior of ceramic restoration

Jiawen Guo, Ding Li, Haijing Wang, Yanwei Yang, Liying Wang, Delin Guan, Yinong Qiu, Lin He, Shaofeng Zhang

Publisher page

Abstract

Aim Ceramic restoration experiences the non-linear wear process during the chewing simulation, which contains running-in, steady and severe wear stages. However since various levels of contact stress may be applied on the occlusal surface during chewing, the cycle-dependent wear behaviors of ceramic crowns may differ. The aim of this study was to investigate the effect of contact stress on the development of wear behavior, as tested in a chewing simulator. Materials and methods Thirty-six anatomical metal-ceramic crowns using Ceramco III as the veneering porcelain were randomly assigned to two groups based on the contact stress applied in the wear testing. Stainless steel balls served as antagonists. The specimens were dynamically loaded in a chewing simulator up to 2.4×106 loading cycles, with additional thermal cycling between 5 and 55℃. For each group, several checkpoints were employed to measure the substance loss of the crowns' occlusal surfaces and to evaluate the microstructure of the worn areas. Results After 2.4×106 cycles, the ceramic restorations with lower contact stress demonstrated a long steady wear stage following the running-in, but without the severe wear stage. And a slowly microstructural degradation was observed that the subsurface defect could not be seen until final. With higher contact stress, however, the ceramic restorations experienced a faster transition from running-in to severe wear stage that the steady wear stage nearly disappeared. And an early formation of subsurface defects and the deterioration of microstructure were observed. Conclusions Contact stress is a key factor affecting the wear development of ceramic restoration. The higher contact stress promotes the veneering porcelain to evolve into severe wear stage. In contrast, lower contact stress is prone to keep the veneering porcelain operating in steady wear stage, which delays the arrival of severe wear region.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Advanced ceramic materials synthesis · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Two-body wear of different ceramic materials opposed to zirconia ceramic10.1016/S0022-3913(10)60102-3 ↗
2. Effect of simulated mastication on the surface roughness of three ceramic systems10.1016/j.prosdent.2015.02.018 ↗
3. Ceramic-like wear behaviour of human dental enamel10.1016/j.jmbbm.2011.12.002 ↗
4. Effect of face form on maximal molar bite force with natural dentition10.1016/j.archoralbio.2008.11.009 ↗
5. Effect of veneering technique on the fracture resistance of zirconia fixed dental prostheses10.1111/j.1365-2842.2012.02323.x ↗
6. Wear properties of dental ceramics and porcelains compared with human enamel10.1016/j.prosdent.2015.09.010 ↗
7. A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms10.1002/jbm.b.33193 ↗
8. Three years in vivo wear: core-ceramic, veneers, and enamel antagonists10.1016/j.dental.2012.02.001 ↗
9. Wear resistance of a pressable low-fusing ceramic opposed by dental alloys10.1016/j.jmbbm.2013.12.018 ↗
10. Two-body wear of resin and ceramic denture teeth in comparison to human enamel10.1016/j.dental.2007.04.012 ↗
11. Occlusal forces during chewing and swallowing as measured by sound transmission10.1016/0022-3913(81)90455-8 ↗
12. Investigation of the time-dependent wear behavior of veneering ceramic in porcelain fused to metal crowns during chewing simulations10.1016/j.jmbbm.2014.08.006 ↗
13. Wear of ceramic and antagonist—a systematic evaluation of influencing factors in vitro10.1016/j.dental.2007.06.016 ↗
14. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure10.1177/00220345990780070801 ↗
15. Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelains10.1016/j.jdent.2012.08.004 ↗
16. Two-body wear comparison of zirconia crown, gold crown, and enamel against zirconia10.1016/j.jmbbm.2014.11.029 ↗
17. Quantitative in vivo wear of human enamel10.1177/00220345890680120601 ↗
18. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing10.1016/j.jdent.2014.09.008 ↗
19. Wear of composite resin veneering materials and enamel in a chewing simulator10.1016/j.dental.2006.11.026 ↗
20. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns10.1016/j.prosdent.2015.03.001 ↗
21. A fractographic study of clinically retrieved zirconia–ceramic and metal–ceramic fixed dental prostheses10.1016/j.dental.2015.07.003 ↗
22. Wear behavior of pressable lithium disilicate glass ceramic10.1002/jbm.b.33447 ↗
23. Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns10.1007/s00784-013-1029-9 ↗
24. Cycle-dependent in vitro wear performance of dental ceramics after clinical surface treatments10.1016/j.jmbbm.2015.08.009 ↗
25. Wear performance of substructure ceramics and veneering porcelains10.1016/j.dental.2011.04.001 ↗
26. Evaluation of molar and incisor bite force in indigenous compared with white population in Brazil10.1016/j.archoralbio.2007.10.003 ↗
27. Sliding contact fracture of dental ceramics: principles and validation10.1016/j.actbio.2014.03.004 ↗
28. Approach for valuating the significance of laboratory simulation10.1016/j.jdent.2008.09.001 ↗
29. Abrasion of human enamel by different dental ceramics in vitro10.1177/00220345910700031301 ↗
30. Occlusal geometrical considerations in all-ceramic pre-molar crown failure testing10.1016/j.dental.2011.08.005 ↗
31. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists10.3109/00016357.2011.654248 ↗
32. Clinical assessment of enamel wear caused by monolithic zirconia crowns10.1111/joor.12409 ↗
33. Relations among mechanical properties, human bite parameters, and ease of chewing of solid foods with various textures10.1016/j.jfoodeng.2009.05.023 ↗
34. Effect of occlusal contact size on interfacial stresses and failure of a bonded ceramic: fea and monotonic loading analyses10.1016/j.dental.2007.06.017 ↗
35. Effect of different dental ceramic systems on the wear of human enamel: an in vitro study10.1016/j.prosdent.2015.09.005 ↗
36. Comparative in vitro wear resistance of CAD/CAM composite resin and ceramic materials10.1016/j.prosdent.2015.07.011 ↗