journal article·2024-02Open access

Effect of abutment screw-access hole on the fatigue performance of implant-supported lithium-disilicate luted simplified restorations

Lucas Saldanha da Rosa, Pablo Machado Soares, Maria Gabriela Packaeser, Gratcheva Falcão Chiapinotto, Atais Bacchi, João Paulo Mendes Tribst, Cornelis Johannes Kleverlaan, Gabriel Kalil Rocha Pereira

Abstract

The present study aimed to evaluate the impact of the existence of an abutment screw-access hole and the filling effects on the fatigue mechanical behavior of a luted lithium-disilicate glass-ceramic. Seventy-two discs (Ø = 10 mm, 1.0 mm in thickness) of lithium disilicate (IPS e.max CAD, Ivoclar AG) were obtained from prefabricated blocks. Thirty-six abutment specimens of an opaque zirconia (Yz - IPS e.max ZirCAD, Ivoclar AG) and titanium (Ti - Luminesse Ti-Cam discs, Talladium Inc.) were confectioned, and allocated according to 6 groups: Yz and Ti rigid (without screw access hole); Yz unfilled, Yz filled, Ti unfilled and Ti filled (with the screw access (Ø = 2.5 mm) in the center). For the unfilled groups, only a polytetrafluoroethylene tape was used. Resin composite (Tetric N-Ceram, Ivoclar AG) was applied to the screw access hole for the filled groups (Yz and Ti). A cyclic fatigue test was carried out (load of 200 N, 10,000 cycles each; 20 Hz of frequency, step size of 100 N until failure detection (radial/cone crack). The fatigue failure load (FFL) and number of cycles until failure (CFF) were recorded for statistical purposes. The stress distribution (MPa) was evaluated by finite element analysis. A statistically positive effect of the abutment material and the presence of the screw access hole was observed (p ≤ 0.05). The rigid groups (without screw access holes) depicted almost 100% of survival after the fatigue tests. Among the other groups, the Yz-filled group showed the best performance (p ≤ 0.05), followed by the Yz unfilled group. The Ti groups depicted lower values of FFL and CFF, with the Ti unfilled group showing the most unfavorable fatigue behavior (p ≤ 0.05). The lowest tensile stress concentration in the restorative material was observed with the use of rigid abutments, the filled groups depicted intermediate values, while unfilled groups showed the highest stress concentration (Yz rigid = 306.3 MPa; Ti rigid = 310.4 MPa < Yz filled = 490.7 MPa; Ti filled = 498.9 MPa < Yz unfilled = 707.6 MPa; Ti unfilled = 719.7 MPa). Therefore, the presence of a screw-access hole decreases the mechanical performance of a lithium disilicate ceramic regardless of the abutment material. In the presence of a screw-access hole, zirconia abutments depicted a higher fatigue failure load when compared with titanium. The filling of the abutment screw-access hole with resin composite increased the mechanical performance of the simulated restoration.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Influence of space size of abutment screw access channel on the amount of extruded excess cement and marginal accuracy of cement-retained single implant restorations10.1016/j.prosdent.2017.03.013 ↗
2. Effect of the unfilled space size of the abutment screw access hole on the extruded excess cement and retention of single implant zirconia crowns10.1111/jopr.12580 ↗
3. Fatigue resistance of Y-TZP/Porcelain crowns is not influenced by the conditioning of the intaglio surface10.2341/14-166-L ↗
4. Clinical performance of one-piece zirconia dental implants: a systematic review10.1111/jicd.12384 ↗
5. A three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: a prospective multicenter study10.1111/clr.13115 ↗
6. Chairside CAD/CAM materials. Part 1: measurement of elastic constants and microstructural characterization10.1016/j.dental.2016.10.009 ↗
7. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants
8. Efficacy of Gutta-Percha and Polytetrafluoroethylene Tape to Microbiologically Seal the Screw Access Channel of Different Prosthetic Implant Abutments10.1111/cid.12344 ↗
9. The fracture resistance of a CAD/CAM resin nano ceramic (RNC) and a CAD ceramic at different thicknesses10.1016/j.dental.2014.05.018 ↗
10. Effect of screw hole filling on retention of implant crowns
11. Viscoelastic finite element analysis of an all-ceramic fixed partial denture10.1016/j.jbiomech.2004.11.007 ↗
12. The effects of new design of access hole on porcelain fracture resistance of implant-supported crowns
13. Survival and mechanical complications of posterior single implant-supported restorations using prefabricated titanium abutments: a medium- and long-term retrospective analysis with up to 10 Years follow-up10.11607/ijp.7669 ↗
14. The effects of abutment wall height, platform size, and screw access channel filling method on resistance to dislodgement of cement-retained, implant-supported restorations10.1111/j.1532-849X.2006.00150.x ↗
15. Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics10.1016/j.dental.2017.07.019 ↗
16. Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: an in vitro comparative and finite element analysis study10.1016/j.prosdent.2020.09.025 ↗
17. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
18. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
19. Dental ceramics: what is this stuff anyway?
20. Development of clinically validated bulk failure test for ceramic crowns10.1016/S0022-3913(10)60129-1 ↗
21. The effect of screw color and technique to fill access hole on the final color of screw-retained implant crowns10.1563/AAID-JOI-D-10-00045.1 ↗
22. Degree of conversion and mechanical properties of resin cements cured through different all-ceramic systems10.1590/0103-6440201300180 ↗
23. Load-bearing properties of minimal-invasive monolithic lithium disilicate and zirconia occlusal onlays: finite element and theoretical analyses10.1016/j.dental.2013.04.004 ↗
24. Fatigue resistance of simplified CAD-CAM restorations: foundation material and ceramic thickness effects on the fatigue behavior of partially- and fully-stabilized zirconia10.1016/j.dental.2021.01.001 ↗
25. The use of polytetrafluoroethylene tape for the management of screw access channels in implant-supported prostheses10.1016/S0022-3913(10)60029-7 ↗
26. Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: fatigue failure load, number of cycles for failure, survival rates, and stress distribution10.1016/j.jmbbm.2018.12.010 ↗
27. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
28. Substrate rigidity effect on CAD/CAM restorations at different thicknesses
29. Internal adjustments decrease the fatigue failure load of bonded simplified lithium disilicate restorations10.1016/j.dental.2018.05.015 ↗
30. Effect of an occlusal screw access hole on the fracture resistance of permanently cemented implant crowns: a laboratory study
31. Load-bearing capacity under fatigue and FEA analysis of simplified ceramic restorations supported by Peek or zirconia polycrystals as foundation substrate for implant purposes10.1016/j.jmbbm.2021.104760 ↗
32. A comparative analysis of restorative materials used in abfraction lesions in tooth with and without occlusal restoration: three-dimensional finite element analysis10.4103/0972-0707.108200 ↗
33. Influence of ceramic material, thickness of restoration and cement layer on stress distribution of occlusal veneers10.1590/1807-3107bor-2018.vol32.0118 ↗
34. Polymerization shrinkage and push-out bond strength of different composite resins for sealing the screw-access hole on implant-supported crowns
35. Accelerated loading frequency does not influence the fatigue behavior of polymer infiltrated ceramic network or lithium disilicate glass-ceramic restorations
36. Biaxial flexure tests of ceramicsubstrates
37. Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis10.1016/j.dental.2005.10.013 ↗
38. Novel zirconia materials in dentistry10.1177/0022034517737483 ↗
39. Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity10.1186/s12903-022-02145-x ↗