journal article·2025-12

SALS-ing is believing: Determining dominant fibre orientation in pericardium using visual inspection and Small Angle Light Scattering (SALS)

L. Guerin, A. Whelan, C. Hughes, D. O'Reilly, E. Campbell, E. Growney, C. Lally

Publisher page

Abstract

Porcine pericardium and bovine pericardium are commonly used materials in medical devices, most notably in the leaflets of bioprosthetic valves. The mechanical and fatigue behaviour of pericardium is influenced primarily by its collagen fibre architecture. Multiple methods exist in the literature for determining the collagen fibre architecture of pericardium, including inspecting the tissue by eye using a light source. However, visual inspection of pericardium has not yet been established to be repeatable or accurate for providing information on mechanically relevant fibre orientations. This study aims to establish the reliability of this visual inspection method. To do this a 'ground truth' for fibre architecture was defined using small angle light scattering (SALS). SALS repeatability was demonstrated by imaging porcine pericardium in four different positions and the ability to determine mechanically relevant tissue fibre orientations by SALS was correlated by uniaxial tensile testing. The repeatability and accuracy of visual inspection using a light source was then investigated, with six researchers identifying by eye the dominant fibre orientation of porcine pericardium in the same four positions from a bank of images. SALS was found to be highly repeatable in determining fibre alignment and the mechanically dominant fibre orientation, regardless of tissue orientation or the surface imaged. Visual inspection was found to be unrepeatable and inaccurate for all six researchers. Based on the data presented in this study, small angle light scattering, and not visual inspection, is recommended for the non-destructive repeatable determination of the mechanically dominant fibre orientation in pericardium.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiovascular Function and Risk Factors · Coronary Interventions and Diagnostics · Cardiovascular Health and Disease Prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Effect of bioprosthetic leaflet anisotropy on stent dynamics of Transcatheter Aortic Valve replacement devices10.1016/j.jmbbm.2024.106650 ↗
2. Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp--Part I: experimental results10.1115/1.429624 ↗
3. Evaluation of transcatheter heart valve biomaterials: biomechanical characterization of bovine and porcine pericardium10.1016/j.jmbbm.2017.08.013 ↗
4. A biomechanical and microstructural analysis of bovine and porcine pericardium for use in bioprosthetic heart valves10.1080/24748706.2021.1938317 ↗
5. Dittfeld · 2025
6. Evolution of scar structure, mechanics, and ventricular function after myocardial infarction in the rat10.1152/ajpheart.00495.2009 ↗
7. Collagen fibre characterisation in arterial tissue under load using SALS10.1016/j.jmbbm.2017.07.036 ↗
8. A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants10.1177/0885328212465482 ↗
9. Customized 3D printed bioreactors for decellularization—High efficiency and quality on a budget10.1111/aor.14034 ↗
10. Pericardial tissue for cardiovascular application: an in-vitro evaluation of established and advanced production processes10.1007/s10856-018-6186-6 ↗
11. Comparison on the properties of bovine pericardium and porcine pericardium used as leaflet materials of transcatheter heart valve10.1111/aor.14074 ↗
12. Planar biaxial testing of heart valve cusp replacement biomaterials: experiments, theory and material constants10.1016/j.actbio.2016.08.036 ↗
13. Correlation of structure and viscoelastic properties in the pericardia of four mammalian species10.1152/ajpheart.1992.263.4.H1095 ↗
14. Transforms and operators for Directional Bioimage Analysis: a survey
15. Collagen fiber architecture of bovine pericardium10.1097/00002480-199407000-00075 ↗
16. Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves10.1002/jbm.10293 ↗
17. The micromechanical behavior of lyophilized glutaraldehyde-treated bovine pericardium under uniaxial tension10.1016/j.jmbbm.2010.06.010 ↗
18. Age dependent differences in collagen alignment of Glutaraldehyde Fixed Bovine pericardium10.1155/2014/189197 ↗
19. Mapping of bovine pericardium to enable a standardized acquirement of material for medical implants10.1016/j.jmbbm.2021.104432 ↗
20. Collagen fibre orientation and dispersion govern ultimate tensile strength, stiffness and the fatigue performance of bovine pericardium10.1016/j.jmbbm.2018.09.038 ↗
21. Collagen fibre-mediated mechanical damage increases calcification of bovine pericardium for use in bioprosthetic heart valves10.1016/j.actbio.2021.04.046 ↗
22. Bovine pericardium of high fibre dispersion has high fatigue life and increased collagen content; potentially an untapped source of heart valve leaflet tissue10.1007/s10439-020-02644-4 ↗
23. Mechanical and structural correlates of canine pericardium10.1161/01.RES.49.3.807 ↗
24. Structured polarized light microscopy for collagen fiber structure and orientation quantification in thick ocular tissues10.1117/1.JBO.23.10.106001 ↗
25. A comprehensive comparison of bovine and porcine decellularized pericardia: new insights for surgical applications10.3390/biom10030371 ↗