Time-dependent in silico modelling of orthognathic surgery to support the design of biodegradable bone plates
Source abstract
Abstract
Orthognathic surgery is performed to realign the jaws of a patient through several osteotomies. The state-of-the-art bone plates used to maintain the bone fragments in place are made of titanium. The presence of these non-degradable plates can have unwanted side effects on the long term (e.g. higher infection risk) if they are not removed. Using a biodegradable material such as magnesium may be a possible solution to this problem. However, biodegradation leads to a decrease of mechanical strength, therefore a time-dependent computational approach can help to evaluate the performance of such plates. In the present work, a computational framework has been developed to include biodegradation and bone healing algorithms in a finite element model. It includes bone plates and the mandible, which are submitted to masticatory loads during the early healing period (two months following the surgery). Two different bone plate designs with different stiffnesses have been tested. The stiff design exhibited good mechanical stability, with maximum Von Mises stress being less than 40% of the yield strength throughout the simulation. The flexible design shows high stresses when the bone healing has not started in the fracture gaps, indicating possible failure of the plate. However, this design leads to a higher bone healing quality after two months, as more cartilage is formed due to higher strains exerted in fracture gaps. We therefore conclude that in silico modelling can support tuning of the design parameters to ensure mechanical stability and while promoting bone healing.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Craniofacial Disorders and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Biodegradable magnesium alloys for orthopaedic applications: A review on corrosion, biocompatibility and surface modifications10.1016/j.msec.2016.06.020 ↗
2. An interface finite element model can be used to predict healing outcome of bone fractures10.1016/j.jmbbm.2013.09.023 ↗
3. Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing10.1080/17453674.2016.1256940 ↗
4. Tissue differentiation and bone regeneration in an osteotomized mandible: a computational analysis of the latency period10.1007/s11517-007-0247-1 ↗
5. Mechanical and corrosion testing of magnesium WE43 specimens for pitting corrosion model calibration10.1002/adem.201800656 ↗
6. Multiscale modeling of bone healing: Toward a systems biology approach10.3389/fphys.2017.00287 ↗
7. A randomized clinical trial of biodegradable and titanium fixation systems in maxillofacial surgery10.1177/0022034511434353 ↗
8. Byun, S.-H., Lim, H.-K., Cheon, K.-H., Lee, S.-M., Kim, H.-E., Lee, J.-H., 0000. Biodegradable magnesium alloy (WE43) in bone-fixation plate and screw, p. 8.
9. Biodegradable bone implants in orthopedic applications: a review10.1016/j.bbe.2020.02.003 ↗
10. Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents10.1016/j.jmbbm.2010.11.003 ↗
11. Influence of fracture gap size on the pattern of long bone healing: a computational study10.1016/j.jtbi.2004.12.023 ↗
12. A 3D computational simulation of fracture callus formation: Influence of the stiffness of the external fixator10.1115/1.2187045 ↗
13. A corrosion model for bioabsorbable metallic stents10.1016/j.actbio.2011.05.032 ↗
14. The influence of fracture fixation biomechanics on fracture healing10.3928/01477447-20100826-20 ↗
15. Kirkland · 2014
16. Three-dimensional finite element stress analysis of the dentate human mandible10.1002/ajpa.1330880107 ↗
17. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading10.1016/S0021-9290(02)00086-6 ↗
18. Numerical simulation of the tissue differentiation and corrosion process of biodegradable magnesium implants during bone fracture healing10.1002/zamm.201700314 ↗
19. Optimal design of a functionally graded biodegradable composite bone plate by using the taguchi method and finite element analysis10.1016/j.compstruct.2014.08.029 ↗
20. Current concepts in orthognathic surgery10.1097/PRS.0000000000004438 ↗
21. Changes in bite force and occlusal contact area after orthognathic surgery for correction of mandibular prognathism10.1067/moe.2001.112334 ↗
22. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology10.1302/0301-620X.84B8.0841093 ↗
23. Biomechanics of fracture healing
24. Finite element analysis of custom shoulder implants provides accurate prediction of initial stability10.3390/math8071113 ↗
25. The key to accuracy of zygoma repositioning: Suitability of the SynpliciTi customized guide-plates10.1016/j.jcms.2014.12.014 ↗
26. Biodegradable metallic bone implants10.1039/C8QM00507A ↗
27. Introduction to force-dependent kinematics: Theory and application to mandible modeling
28. Is the removal of osteosynthesis plates after orthognathic surgery necessary? Retrospective long-term follow-up study10.1016/j.ijom.2018.07.001 ↗
29. Discharge patterns of orthognathic surgeries in the United States10.1016/j.joms.2011.09.030 ↗
30. Time-dependent topology optimization of bone plates considering bone remodeling10.1016/j.cma.2019.112702 ↗
31. Validation of a musculo-skeletal model of the mandible and its application to mandibular distraction osteogenesis10.1016/j.jbiomech.2006.06.024 ↗
32. In silico study of bone tissue regeneration in an idealised porous hydrogel scaffold using a mechano-regulation algorithm10.1007/s10237-017-0941-3 ↗
33. Investigation on masticatory muscular functionality following oral reconstruction – An inverse identification approach10.1016/j.jbiomech.2019.04.007 ↗