Further experimental evidence of the compressibility of arteries
Source abstract
Abstract
Further experimental evidence on the compressibility of arteries under normal physiological pressure range is provided using the experimental apparatus introduced in Yosibash et al., JMBBM 39(2014):339-354. We enlarged the experimental database by including almost twice the number of experiments, we considered a different artery - the porcine common carotid that allowed longer and larger diameters. In the physiological pressure range of 50-200mmHg, a relative volume change of 5% was obtained, lower compared to the sapheneous and femoral arteries (2-6%). Most of the arteries had a relative volume change of 1.5%. The relative volume change is found to be almost linearly proportional to the pressure, and inversely proportional to the dimensions of the experimented arteries (especially the artery length). The smaller the artery tested, the larger the relative volume change (such a phenomenon was also realized in Yosibash et al., JMBBM 39(2014):339-354.). We realized in recent past publications a flaw in the experimental protocol that results in an overestimation of the relative volume change (thus underestimating the bulk modulus). It is due to the consideration of experimental observations close to the zero pressure. Nontheless, in view of the experimental evidence, the pre-assumption of incompressibility in many phenomenological constitutive models of artery walls should be re-evaluated.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Cardiovascular Health and Disease Prevention · Coronary Interventions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Active axial stress in mouse aorta10.1016/j.jbiomech.2012.05.025 ↗
2. Comparison of femoral and auricular arterial blood pressure monitoring in pigs10.1111/j.1467-2995.2009.00484.x ↗
3. Review of experimental investigations on compressibility of arteries and introduction of a new apparatus10.1007/s11340-012-9614-4 ↗
4. Biomechanical phenotyping of central arteries in health and disease: Advantages of and methods for murine models10.1007/s10439-013-0799-1 ↗
5. Hannon, J., Bossone, C., Wade, C., 1989. Normal Physiological Values for Concious Pigs Used in Biomedical Research. Tech. Rep., Letterman Army Institute of Research, San Francisco, California.
6. Constitutive modelling of arteries10.1098/rspa.2010.0058 ↗
7. On the compressibility of arterial tissue10.1007/s10439-015-1417-1 ↗
8. Experimental evidence of the compressibility of arteries10.1016/j.jmbbm.2014.07.030 ↗