Mechanical performance, corrosion and tribological evaluation of a Co–Cr–Mo alloy processed by MIM for biomedical applications
Source abstract
Abstract
In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co-Cr-Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks, the optimum choice of the powder loading and the design of the debinding and sintering cycles. The mechanical properties as regards hardness, tensile strength and bending strength, as well as fatigue tests and wear characterization, are discussed for the full densified specimens obtained. Additionally, corrosion behaviour with the different methods and electrolytic solutions that simulate the biological environment has also been investigated. This approach allows us to confirm that the low-carbon cobalt alloy processed by MIM exhibits an adequate equilibrium between its mechanical and corrosion behaviour, with a notable performance during fatigue and wear tests. In the light of these findings, the use of this material for biomedical applications is discussed.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Injection Molding Process and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. Corrosion fatigue of biomedical metallic alloys: mechanisms and mitigation10.1016/j.actbio.2011.09.012 ↗
2. Powder injection molding of biocompatible stainless steel biodevices10.1016/j.powtec.2016.03.039 ↗
3. ASTM G99-05 · 2005
4. Influence of post processing on the mechanical properties of investment cast and wrought Co-Cr-Mo alloys
5. Influence of grain boundaries on dissolution behavior of a biomedical CoCrMo alloy: in-situ electrochemical-optical, AFM and SEM/TEM studies10.1149/2.056209jes ↗
6. Metallic implant biomaterials10.1016/j.mser.2014.10.001 ↗
7. Pin-on-disk wear behavior in a like-on-like configuration in a biological environment of high carbon cast and low carbon forged Co–29Cr–6Mo alloys10.1016/j.actamat.2006.10.005 ↗
8. 1993 · 13A
9. The corrosion studies of powder metallurgy Co-Cr-Mo (F-75) alloy
10. 1999 · 225
11. Dry sliding and tribocorrosion behaviour of hot pressed CoCrMo biomedical alloy as compared with the cast CoCrMo and Ti6Al4V alloys10.1016/j.matdes.2013.05.032 ↗
12. 2017
13. Influence of surface quality and porosity on fatigue behaviour of Ti–6Al–4V components processed by MIM10.1016/j.msea.2009.11.007 ↗
14. Effect of adding carbides on dry sliding wear behaviour of steel matrix composites processed by metal injection moulding10.1016/j.wear.2018.08.010 ↗
15. German · 1990 · 521
16. Microstructural evolution during solution treatment of Co–Cr–Mo–C biocompatible alloys10.1016/j.matchar.2012.03.006 ↗
17. A review of biocompatible metal injection moulding process parameters for biomedical applications10.1016/j.msec.2017.05.016 ↗
18. Characterization of the surface oxide film of a Co–Cr–Mo alloy after being located in quasi-biological environments using XPS10.1016/S0169-4332(01)00551-7 ↗
19. Hansen · Interface · 2008 · 17 · 31
20. Hermawan · 2011
21. Control of carbon content in metal injection molding
22. Passive and transpassive behaviour of CoCrMo in simulated biological solutions10.1016/j.electacta.2003.12.043 ↗
23. Advanced Stellite alloys with improved metal-on-metal bearing for hip implants10.1016/j.matdes.2014.04.007 ↗
24. Metal injection molding of Co-28Cr-6Mo
25. An overview on the tribological performance of titanium alloys with surface modifications for biomedical applications10.3390/lubricants7080065 ↗
26. Advances in metals and alloys for joint replacement10.1016/j.pmatsci.2017.04.002 ↗
27. Isothermal phase transformation in biomedical Co-29Cr-6Mo alloy without addition of carbon or nitrogen10.1007/s11661-010-0273-8 ↗
28. Effect of sigma phase in Co-29Cr-6Mo alloy on corrosion behavior in saline solution10.2320/matertrans.47.1961 ↗
29. Landolt · 2011
30. Significant improvement in mechanical properties of biomedical Co-Cr-Mo alloys with combination of N Addition and Cr-enrichment10.2320/matertrans.MRA2007220 ↗
31. New insights into hard phases of CoCrMo metal-on-metal hip replacements10.1016/j.jmbbm.2012.03.013 ↗
32. Tribological and mechanical performance evaluation of metal prosthesis components manufactured via metal injection molding
33. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
34. Effect of carbon on the microstructure, mechanical properties and metal ion release of Ni-free Co-Cr-Mo alloys containing nitrogen10.1016/j.msec.2015.05.058 ↗
35. Microstructure and tensile properties of metal injection molding Co–29Cr–6Mo–0.23C alloy10.1007/s10853-009-4051-1 ↗
36. In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements10.1002/jbm.b.31794 ↗
37. 2012
38. Microabrasion of three experimental cobalt-chromium alloys: wear rates and wear mechanisms10.1016/j.wear.2017.07.023 ↗
39. In vitro analyses of the toxicity, immunological, and gene expression effects of cobalt-chromium alloy wear debris and Co ions derived from metal-on-metal hip implants10.3390/lubricants3030539 ↗
40. Strassburger · 2012
41. Net-shaping of Co-Cr-Mo (F-75) via metal injection molding
42. Fatigue of biomaterials: a review10.1016/S0142-1123(00)00052-9 ↗
43. Surface composition and corrosion resistance of Co-Cr alloys containing high chromium10.2320/matertrans.MI201514 ↗
44. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids10.1016/j.corsci.2008.04.002 ↗
45. Influence of carbides and microstructure of CoCrMo alloys on their metallic dissolution resistance10.1016/j.msec.2013.07.041 ↗
46. 2004 · vol. 9
47. Venable · J. Am. Med. Assoc. · 1938 · 111 · 134910.1001/jama.1938.02790410005002 ↗
48. Passivation of a CoCrMo PVD alloy with biomedical composition under simulated physiological conditions studied by EQCM and XPS10.1149/2.090205jes ↗
49. Special modes of corrosion under physiological and simulated physiological conditions10.1016/j.actbio.2007.12.003 ↗
50. Release of metal ions from nano CoCrMo wear debris generated from tribo-corrosion processes in artificial hip implants10.1016/j.jmbbm.2017.01.041 ↗
51. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators10.1016/j.jmbbm.2012.08.009 ↗
52. Zierold · Arch. Surg. · 1924 · 9 · 36510.1001/archsurg.1924.01120080133008 ↗
53. Microstructure on the properties of a biomedical Co-Cr-Mo alloy produced by MIM