Predicting osteosynthesis screw failure by peri-implant bone morphology in multiple loading conditions
Source abstract
Abstract
Osteosynthesis screws are critical in orthopaedic surgery for stabilizing and aligning bone fracture fragments. Despite their importance, screw failure remains a significant complication, often due to excessive movement at the implant-bone interface resulting from both physiological loading and external mechanical forces. This study aims to enhance understanding of screw failure mechanisms by investigating the relationship between peri-implant CT-based trabecular bone morphology and screw failure under axial-, shear-, and mixed loading conditions, including the effect of plate elevation. Using high-resolution micro-computed tomography (micro-CT) and mechanical testing, 100 porcine epiphyseal bone samples were extracted and analysed to measure key CT-based trabecular morphometric indices and correlate them with mechanical failure. The study tested screws under ten different loading configurations. Statistical analyses revealed that bone volume (BV) and bone volume over total volume (BV/TV) are strong predictors of screw failure force, explaining 70-90 % of the variance in failure forces across different loading scenarios. The findings suggest that BV and BV/TV can be used to determine optimal screw implantation sites based on local bone morphology, potentially improving surgical outcomes and reducing postoperative complications. This research contributes to a more comprehensive understanding of orthopaedic screw behaviour and offers a predictive model for clinical use.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Dental Radiography and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density10.1016/j.jmbbm.2014.09.009 ↗
2. Peri-implant bone microstructure determines dynamic implant cut-out10.1016/j.medengphy.2013.03.016 ↗
3. Trabecular deformations during screw pull-out: a micro-CT study of lapine bone10.1007/s10237-017-0891-9 ↗
4. Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus10.1016/0021-9290(94)90054-X ↗
5. Measurement of bone damage caused by quasi-static compressive loading-unloading to explore dental implants stability: simultaneous use of in-vitro tests, μ-CT images, and digital volume correlation10.1016/j.jmbbm.2022.105566 ↗
6. Bone damage evolution around integrated metal screws using X-Ray tomography — in situ pullout and digital volume correlation10.3389/fbioe.2020.00934 ↗
7. Axial and shear pullout forces of composite, porcine and human metatarsal and cuboid bones10.1016/j.jot.2018.06.001 ↗
8. Significance of primary stability for osseointegration of dental implants10.1111/j.1600-0501.2005.01201.x ↗
9. Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone10.1016/j.jmbbm.2021.105002 ↗
10. Experimental and numerical investigation of secondary screw perforation in the human proximal humerus10.1016/j.jmbbm.2021.104344 ↗
11. Pickard, M.B., Dechow, P., Emile Rossouw, P., Buschang Moscow, P.H., n.d. Effects of miniscrew orientation on implant stability and resistance to failure. https://doi.org/10.1016/j.ajodo.2007.12.034.10.1016/j.ajodo.2007.12.034 ↗
12. Pullout strength of suture anchors: effect of mechanical properties of trabecular bone10.1016/j.jbiomech.2009.12.007 ↗
13. The behavior of cancellous bone from quasi-static to dynamic strain rates with emphasis on the intermediate regime10.1016/j.jbiomech.2016.02.021 ↗
14. Ridler · 1978
15. Osteointegration of hydroxyapatite-coated and uncoated titanium screws in long-term ovariectomized sheep10.1016/S0142-9612(01)00213-7 ↗
16. Thread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis10.1038/s41598-022-16662-w ↗
17. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws10.1016/j.orthres.2004.04.001 ↗
18. Post-yield mechanical properties of bovine trabecular bone – relationships with bone volume fraction and strain rate10.1016/j.engfracmech.2020.107053 ↗
19. Selection of animal bone surrogate samples for orthopaedic screw testing based on human radius CT-derived bone morphology10.1016/j.medengphy.2022.103786 ↗
20. Critical loss of primary implant stability in osteosynthesis locking screws under cyclic overloading10.1016/j.medengphy.2024.104143 ↗
21. Synek · 2015
22. The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: evaluations and comparison to experiments10.1016/j.jbiomech.2015.10.012 ↗
23. Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., Dubruille, J.H., n.d. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. https://doi.org/10.1002/(SICI)1097-4636(199822)43:2.
24. Correlation between bone volume fraction in posterior implant area and initial implant stability10.1016/j.oooo.2021.08.008 ↗
25. Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws10.1016/j.jse.2005.09.007 ↗
26. Pullout performance comparison of pedicle screws based on cement application and design parameters10.1177/0954411915612494 ↗
27. Factors influencing primary and secondary implant stability—A retrospective cohort study with 582 implants in 272 patients10.3390/app10228084 ↗
28. Peroperative estimation of bone quality and primary dental implant stability10.1016/j.jmbbm.2018.12.035 ↗
29. Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses10.1007/s00419-009-0387-x ↗
30. Implant stability is affected by local bone microstructural quality10.1016/j.bone.2011.05.001 ↗