journal article·2012-02

Lubrication of metal-on-metal hip joints: The effect of protein content and load on film formation and wear

C. Myant, R. Underwood, J. Fan, P.M. Cann

Publisher page

Abstract

Lubricant films were measured for a series of bovine serum and protein containing (albumin, globulin) saline solutions for CoCrMo femoral component sliding against a glass disc. Central film thickness was measured by optical interferometry as a function of time (constant mean speed: 0 and 10 mm/s) and variable mean speed (0-50 mm/s). The effect of load (5-20 N) on film thickness was also studied. The development of the wear scar on the CoCrMo surface was monitored by measuring the width of the contact zone during the film thickness tests. The results showed film thickness increased with time for both the static and sliding tests. Films formed in the static, loaded test were typically in the range of 3-40 nm. The globulin containing solutions formed the thickest films. In the sliding tests a wear scar rapidly formed on the implant component for the bovine serum and albumin fluids, negligible wear was observed for the globulin solutions. Film thickness increased with sliding time for all test solutions and was much greater than predicted by isoviscous EHL models. The film increase was found to correlate with increasing wear scar size and thus decreasing contact pressure. A new lubricating mechanism is proposed whereby during sliding the fluid undergoes bulk phase separation rheology, so that an elevated protein phase forms in the inlet zone. This protein phase is a high-viscosity biphasic matrix, which is periodically entrained into the contact forming a thick protective hydro-gel film. One of the main findings of this study is that film thickness was very sensitive to load; to a much greater extent than predicted by EHL models. Thus film formation in MoM hip joints is very susceptible to high contact pressures which might be due to implant misalignment and edge-loading.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Powder Metallurgy Techniques and Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints10.1243/0954411011533661 ↗
2. The development of a spacer layer imaging method (SLIM)10.1080/10402009608983612 ↗
3. The rheology of synovial fluid and some potential synthetic lubricants for degenerate synovial joints
4. Changes in joint fluid after total arthoplasty
5. Tribological principles in metal-on-metal hip joint design10.1243/095441105X63255 ↗
6. Dwyer-Joyce, R.S., 1993. The effects of lubricant contamination in rolling element performance. Ph.D. Thesis. Imperial College: University of London Press.
7. Inlet protein aggregation: a new mechanism for lubricating film formation with model synovial fluids10.1177/0954411911401306 ↗
8. The elastohydrodynamic lubrication of heavily-loaded point contacts10.1243/JMES_JOUR_1980_022_036_02 ↗
9. The measurement and study of very thin lubricant films in concentrated contacts10.1080/10402009108982026 ↗
10. Constituents and pH changes in protein rich hyaluronan solution affect the biotribological properties of artificial articular joints10.1016/S0021-9290(01)00058-6 ↗
11. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip10.1302/0301-620X.90B9.20785 ↗
12. The entrapment of corrosion products from CoCr implant alloys in the deposits of calcium phosphate: a comparison of serum, synovial fluid, albumin, EDTA, and water10.1002/jor.20198 ↗
13. Frictional heating of bearing materials tested in a lubricant in a hip joint wear simulator10.1243/0954411971534728 ↗
14. Formation of absorbed protein layers10.1006/jcis.1998.5763 ↗
15. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses10.1002/jbm.b.31671 ↗
16. MHRA, 2010. Medical Device Alert, April.
17. Myant, C., 2010. Experimental techniques for investigating lubricated, compliant, contacts. Thesis. Imperial College Press.
18. National Joint Registry, 2010. 7th Annual Report.
19. Rheopexy of synovial fluid and protein aggregation10.1098/rsif.2005.0086 ↗
20. Biological reaction to debris in relation to joint prostheses10.1243/0954411971534304 ↗
21. Influence of protein and lipid concentration of the test lubricant on the wear of ultra-high molecular weight polyethylene10.1016/j.triboint.2007.11.010 ↗
22. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements10.1243/0954411011533724 ↗
23. Thin films in elastohydrodynamic lubrication: the contribution of experiment10.1243/1350650991542712 ↗
24. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements10.1016/S0301-679X(98)00005-X ↗
25. The effects of lubricant composition on in vitro wear testing of polymeric acetabular components10.1002/jbm.b.10077 ↗
26. Influence of polymer surface chemistry on frictional properties under protein-lubrication conditions: implications for hip-implant design10.1023/A:1009074228662 ↗
27. Tribochemical reaction on metal-on-metal hip joint bearings. A comparison between in-vitro and in-vivo results10.1016/S0043-1648(03)00127-3 ↗