journal article·2020-09-01

Performance of Thin-Wall Synthetic Fiber–Reinforced Concrete Pipes under Short and Long-Term Loading

Fouad T. Al Rikabi, Shad M. Sargand, John Kurdziel, Issam Khoury

Journal of Testing and Evaluation· Volume 48· Issue 5
Publisher page

Abstract

Abstract Synthetic fibers have been recently used as a replacement for conventional steel reinforcement in concrete pipes to enhance their durability, ductility, shear strength, and flexural strength. However, there is very limited understanding of the long-term performance of thin-wall synthetic fiber–reinforced concrete pipes, as synthetic fiber has material properties that may change with a sustained load over time. This research investigates the performance of polypropylene fiber–reinforced concrete pipe under short and long-term loads in terms of strength, deflection response, strain response, crack width, and crack patterns. Concrete pipes with diameters of 1,200 and 1,500 mm with respective wall thicknesses of 50 and 63 mm were subjected to the short-term three-edge bearing test. To ensure maximum fiber contribution to pipe strength, a 9 kg/m3 fiber dosage was used with different amounts of steel reinforcement. For the long-term three-edge bearing test, a pipe with a diameter of 1,200 mm reinforced with fiber dosage of 9 kg/m3 along with steel reinforcement with an area of 5.7 cm2/m was tested for 30 days at 40 % of the ultimate load (Load Stage 1) obtained from the short-term test, for another 30 days at 50 % ultimate load (Load Stage 2), and subsequently at 70 % ultimate load for a final 30 days (Load Stage 3). Short-term results showed that synthetic fiber was a viable replacement for the steel reinforcement cage, as some of the tested pipe achieved the strength requirement specified by ASTM C76-15a, Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe. In response to sustained load, the tested pipe initially exhibited a linear response, followed by a stable response with a slight increase in deflection over time. Fiber creep did not significantly increase the crack width or affect the time dependence of the strain, indicating that the fibers adequately transfer the stress in the pipe wall and limit the crack width. The cracks propagated longitudinally at the invert, crown, and springline, where there were high flexural tensile stresses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Geotechnical Engineering and Underground Structures · Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, Ohio University, 28 W Green Dr. 1 , Athens, OH 45701 ,

Department of Civil Engineering, Ohio University, 28 W Green Dr. 2 , Athens, OH 45701 ,

Technical Services and Market Development, Advanced Drainage Systems, Inc., 4640 Trueman Blvd. 3 , Hilliard, OH 43026 ,

References (25)

Show source-provided references
1. Plastics Pipe Institute, “Design Methodology,” Corrugated Polyethylene Pipe Design Manual and Installation Guide, Plastics Pipe Institute, https://plasticpipe.org/drainage/cppa-ppi-handbook.html
2. Thin-Walled Flexible Concrete Pipes with Synthetic Fibers and Reduced Traditional Steel Cage10.1016/j.engstruct.2015.06.049 ↗
3. Enhancement of the Structural Efficiency and Performance of Concrete Pipes through Fiber Reinforcement10.1016/j.conbuildmat.2013.03.084 ↗
4. Structural Design Methodologies for Concrete Pipes with Steel and Synthetic Fiber Reinforcement10.14359/51686432 ↗
5. Design of Macro-Synthetic Fibre Reinforced Concrete Pipes10.1016/j.conbuildmat.2013.02.036 ↗
6. Performance of Synthetic Fiber-Reinforced Concrete Pipes10.1061/(ASCE)PS.1949-1204.0000166 ↗
7. Evaluation of Synthetic Fiber Reinforced Concrete Pipe Performance Using Three-Edge Bearing Test10.1520/JTE20170369 ↗
8. The Effects of High Temperature on Mechanical Properties of Cementitious Composites Reinforced with Polymeric Fibers10.1016/j.compositesb.2012.09.033 ↗
9. Investigation of Freeze–Thaw Effects on Mechanical Properties of Fiber Reinforced Cement Mortars10.1016/j.compositesb.2013.11.013 ↗
10. Processing of High-Performance Fiber-Reinforced Cement-Based Composites10.1016/j.conbuildmat.2007.06.018 ↗
11. Shear Behavior of Macro-Synthetic Fiber-Reinforced Concrete Beams without Stirrups10.14359/56659 ↗
12. 1992
13. Time-Dependent Behavior of Synthetic Fiber-Reinforced Concrete Pipes under Long-Term Sustained Loading10.3141/2407-07 ↗
14. The Need to Consider Flexural Post-Cracking Creep Behavior of Macro-Synthetic Fiber Reinforced Concrete10.1016/j.conbuildmat.2017.05.166 ↗
15. Time-Dependent Behaviour of Pre-Cracked Polypropylene Fibre Reinforced Concrete (PFRC) under Sustained Loading
16. Tensile Creep of Macro-Synthetic Fibre Reinforced Concrete (MSFRC) under Uni-axial Tensile Loading10.1016/j.cemconcomp.2014.08.002 ↗
17. Testing and Modelling the Creep of Cracked Macro-Synthetic Fibre Reinforced Concrete (MSFRC) under Flexural Loading10.1617/s11527-016-0795-7 ↗
18. Influence of Fiber Type on Creep Deformation of Cracked Fiber-Reinforced Shotcrete Panels10.14359/51663967 ↗
19. Post-Crack Creep Behavior of Steel and Synthetic FRC under Flexural Loading
20. Characterising the Time-Dependant Behaviour on the Single Fibre Level of SHCC: Part 1: Mechanism of Fibre Pull-Out Creep10.1016/j.cemconres.2009.06.007 ↗
21. Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Superseded), ASTM C76-15a (West Conshohocken, PA: ASTM International, 2015). https://doi.org/10.1520/C0076-1510.1520/C0076-15 ↗
22. Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile (Superseded), ASTM C497-15 (West Conshohocken, PA: ASTM International, 2015). https://doi.org/10.1520/C0497-1510.1520/C0497-15 ↗
23. Experimental Investigation of Thin-Wall Synthetic Fiber Reinforced Concrete Pipes10.14359/51702413 ↗
24. Barcelona Test as an Alternative Method to Control and Design Fiber-Reinforced Concrete Pipes10.14359/51689018 ↗
25. Standard Practice for Direct Design of Precast Concrete Pipe Using Standard Installations (SIDD) · 1998