Fire Pattern Repeatability: A Study in Uncertainty
Source abstract
Abstract
Abstract The National Institute of Standards and Technology (NIST) is conducting a multi-year study, with the support of the National Institute of Justice (NIJ) and the NIST Office of Law Enforcement Standards (OLES), to examine the repeatability of fire patterns. The primary objective of the study is assessing the repeatability of fire patterns on gypsum board exposed to a limited range of source fires. The focus of this paper is an overview of the uncertainties of the measurements. The study required the use of a variety of measurements to determine the repeatability of the source fires in terms of heat release rate, temperature, heat flux, and flame height. Replicate source fire experiments were conducted in an oxygen consumption calorimeter in order to examine the repeatability of the fires in terms of the heat release rate. The flame movement and height for each fire were recorded with photographs and videos. The fire pattern experiments were conducted in a three-walled structure with a full floor and partial ceiling constructed from wood framing and lined with painted gypsum board. The source fires were positioned against the rear wall, midway along its length. Replicate experiments were conducted with each fuel. The fire patterns were documented and analyzed for repeatability. The fire pattern height results are then compared to the mean flame height results to examine the level of agreement.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Evacuation and Crowd Dynamics · Wind and Air Flow Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
National Institute of Standards and Technology 1 , Gaithersburg, MD20899, US .
Dept. of Civil and Natural Resources Engineering, Univ. of Canterbury 2 Ph.D., , Christchurch, NZ 8140.
References (31)
Show source-provided references
1. NFPA 921, 2011, “Guide for Fire and Explosion Investigations,” National Fire Protection Association, Quincy, MA.
2. J. R. · 2004
3. N. N. · 2004
4. DeHaan · 2007
5. Icove · 2009
6. Lentini · 200610.1201/9781420003819 ↗
7. Noon · 1995
8. Shanley, J. H. , 1998, “USFA Study of Fire Patterns.” U.S. Fire Administration, Emittsburg, MD.
9. Putorti, A. D. , “Full Scale Room Burn Pattern Study,” NIJ Report No. 601-97, National Institute of Justice, Washington, D.C., Dec 1997.
10. 2009
11. Fire Protection Research Foundation, “Recommendations of The Research Advisory Council on Post-fire Analysis,” Quincy, MA, Feb 2002.
12. Rohr, K. D. , “The U.S. Home Product Report, Forms and Types of Materials First Ignited in Fires: Flammable or Combustible Liquids,” National Fire Protection Association, Quincy, MA, Dec 2001.
13. Babrauskas · 2003
14. Chasteen, C. , Division of the State Fire Marshal, State of Florida, personal communication, April 2010.
15. 2007
16. Rohr, K. D. , “Products First Ignited in U.S. Home Fires,” National Fire Protection Association, Quincy, MA, April 2005.
17. Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
18. Bryant, R. A., Ohlemiller, T. J., Johnsson, E. L., Hamins, A. H., Grove, B. S., Guthrie, W. F., Maranghides, A., and Mulholland, G.W., “The NIST 3 MW Quantitative Heat Release Rate Facility: Description and Procedures,” NISTIR Report No. 7052, National Institute of Standards and Technology, Gaithersburg, MD, Sept 2004.10.6028/NIST.IR.7052 ↗
19. Medtherm Corporation Bulletin 118, “64 Series Heat Flux Transducers,” Medtherm Corporation, Huntsville, AL, 082003.
20. Round Robin Study of Total Flux Gauge Calibration at Fire Laboratories10.1016/j.firesaf.2006.04.004 ↗
21. National Type Evaluation Program, Certificate Number 00-075A1, Model K-series, Mettler-Toledo, Worthington, OH, Dec 2002.
22. 2004 · Z-39
23. Behavior of Bare and Aspirated Thermocouples in Compartment Fires
24. Temperature Uncertainties for Bare-Bead and Aspirated Thermocouple Measurements in Fire Environments
25. Taylor, B. N., and Kuyatt, C. E., “Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results,” NIST Report No. TN 1297, National Institute of Standards and Technology, Gaithersburg, MD, Sept 1994.
26. Nokes · 2011
27. Goble, K. , 2007, “Height of Flames Projecting from Compartment Openings,” Master’s thesis, Dept. of Civil and Natural Resources Engineering, Univ. of Canterbury, Christchurch, NZ.
28. McCaffery, B. J. , “Purely Buoyant Diffusion Flames: Some Experimental Results,” Report No. NBSIR 79-1910, National Bureau of Standards (currently NIST), Gaithersburg, MD, Oct 1979.10.6028/NBS.IR.79-1910 ↗
29. Standard Specification for Gypsum Board
30. Fire Plumes, Flame Height and Air Entrainment
31. Fire Plumes and Ceiling Jets10.1016/0379-7112(86)90052-4 ↗