A method of assessing the effect of foundation settlement upon the ovalization at the top of floating roof storage tanks is presented. The accuracy of the method is tested by comparison with field measurements and experiments on model tanks. Current design specifications for the permissible foundation settlement are reviewed and the extent to which they limit tank ovalization is assessed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Oil and Gas Production Techniques · Fluid Dynamics Simulations and Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Engineering Science, University of Oxford
References (9)
Show source-provided references
1. Debeer E. · Annal. l'Inst. Belge Pétrole · 1969 · 6 · 25
2. Hunt R. E. ‘Steel storage tank foundations II’, Oil Gas Jnl Dec 1967, 67–71.
3. Green P. A., Hight D. W. ‘The failure of two oil-storage tanks caused by differential settlement’, Settlement of structures, Symp. Br. Geotech. Soc., Cambridge 1974, 353–360.
4. Young W. B., Trammel J. H. ‘Why wider rim spaces for large oil storage tanks?’, C.B.I. News July 1974.
5. Langeveld J. M. ‘Welding of storage tanks for the oil and gas industries’, I.I.W. Annual Assembly, Budapest 1974, 35–97.
6. Guber F. H. ‘Design engineering contributions to quality tankage’, I.I.W. Annual Assembly, Budapest 1974, 99–129.
7. Belloni L., Garassino A., Jamiolkowski M. ‘Differential settlement of petroleum steel tanks’, Settlement of structures, Symp. Br. Geotech. Soc., Cambridge 1974, 323–328.
8. Love A. E. H.
9. A.P.I. 650 Welded tanks for oil storage American Petroleum Institute, 1973.